Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1990-1994  (3)
  • 71.00  (1)
  • Liver, neoplasms  (1)
  • MR imaging  (1)
  • Amyloidosis
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 59 (1994), S. 245-251 
    ISSN: 1432-0630
    Keywords: 71.00 ; 61.70
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Abstract An electron trap having an energy level of 0.14 eV from the conduction band edge was found in the bulk of copper-diffused VPE-grown n-GaAs0.6P0.4 by conventional DLTS measurements and by pulse-duration dependent capacitance amplitude measurements. The capture cross section at room temperature is about 1.0×10−21 cm2 and has a weak temperature dependence. These properties are attributed to a non-repulsive center having a capturing mechanism which involves multiphonon emission processes with hardly any lattice relaxation. Evolution of the spatial distributions of the traps with time under junction electric field were studied. The results suggest that the trap is positively charged and has a high diffusivity under electric field. The center can thus be identified as positively charged interstitial copper ion rather than some form of copper complexes.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-0509
    Keywords: Liver, neoplasms ; Sonography ; Angiography ; Computed tomography ; Oily contrast media
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract To evaluate the characteristics of combined hepatocellular and cholangiocarcinoma of the liver by imaging techniques, six patients (five male and one female), aged 46–60 years, with proved combined tumors were selected for this study from the review of 500 resected specimens of liver tumors. Images obtained from sonography, computed tomography (CT), angiography, and CT after intraarterial injection of iodized oil (iodized-oil CT) were retrospectively reviewed and correlated with the appearance of pathologic specimens. Sonographic findings were round or ovoid hypoechoic masses with central hyperechoic area (target appearance) in all patients. On CT scans, tumors were relatively well-defined low- and/or iso-attenuation masses in all patients. Angiography showed hypovascular masses in five patients. In one patient, the tumor appeared as a hypovascular mass with a central hypervascular area. On iodized-oil CT scans, all patients showed partial retention of iodized oil in tumors. Echogenicity in tumors at sonography or attenuation in tumors at CT could not be correlated with histologic difference in tumors at pathologic specimens. However, the hypervascular area at angiography and the compact retention areas of iodized oil at iodized-oil CT corresponded to portions of hepatocellular carcinoma within the combined tumor. On the basis of our results, imaging features, including target appearance at sonography, hypovascular mass with central hypervascular portions at angiography, and partial retention of iodized oil in tumors at iodized-oil CT, might be helpful in making accurate diagnosis of these rare tumors.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-1920
    Keywords: MR imaging ; Brain ; Partial flip angle ; T2-weighted spin-echo
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary To assess the clinical usefulness of partial flip angle (PFA) spin-echo (SE) brain imaging, a total of eighty patients were examined with both conventional double echo T2-weighted SE (2500/30, 80/90o/one excitation) and PFA double echo SE (1200/30, 70/45o/two excitations) on 2.0T system. Two comparative studies were performed: (1) in 65 patients PFA SE technique was compared with conventional SE without flow compensating gradients, and (2) in 15 patients the former was compared with the latter with flow compensating gradients. Imaging time was nearly identical in each sequence. In both studies we found that PFA T2-weighted SE images were almost identical to those obtained with the conventional SE technique in the contrast characteristics and the detection rate of the abnormalities (100%, 85/85 lesions), and more importantly, PFA SE revealed few flow artifacts in the brain stem, temporal lobes and basal ganglia which were frequently seen on conventional SE without flow compensating gradients. Additionally, PFA SE images demonstrated no suppression of CSF flow void in the aqueduct which was commonly seen on conventional SE with flow compensating gradients. In overall image quality, the PFA SE images, particularly the second echo images, were almost comparable with those of conventional SE with flow compensating gradients. A flip angle of 45o seems to be close to Ernst angle, the angle at which maximum signal occurs, for a given TR of 1200 msec for CSF and most of the abnormalities containing higher water content. In conclusion, PFA SE sequence (i. e. 1200/30, 70/45o/2) appears to be useful as a primary or an adjunctive technique in certain clinical circumstances, particularly in imaging of hydrocephalic patients for assessing aqueductal patency.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...