Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1990-1994  (3)
  • Absorbable clips  (1)
  • Anti-nucleolar antibodies  (1)
  • Chemistry  (1)
  • 1
    ISSN: 1432-1440
    Keywords: Eosinophilia myalgia syndrome ; Fibromyalgia syndrome ; Anti-serotonin antibodies ; Anti-ganglioside antibodies ; Anti-phospholipid antibodies ; Anti-nucleolar antibodies
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Eosinophilia myalgia syndrome (EMS) has been related to intake of “contaminated” L-tryptophan, and an alteration in tryptophan 5-hydroxytryptamine (5-HT, serotonin) metabolism has been reported in EMS patients. Recently we found that a defined autoantibody pattern consisting of antibodies to nucleoli, gangliosides, and phospholipids is closely related to the fibromyalgia syndrome (FS) which clinically resembles the EMS. We were therefore interested to see whether these antibodies can also be detected in patients with EMS. Studied were 27 patients with acute EMS (13 of whom were also examined 2 years after acute onset), 100 patients with FS, and 40 patients with progressive systemic sclerosis (PSS). As controls, sera from 100 blood donors were analyzed. Antibodies to nucleoli were demonstrated by immunofluorescence test on cell cultures in 52% of patients with acute EMS, 62% of patients with chronic EMS, and 37% of FS patients. Western blotting with a nuclear extract from HeLa cells revealed in both diseases the same epitopes at 63, 57, and 53 kDa. Antibodies to 5-HT, gangliosides (Gm1), and phospholipids were determined by enzyme-linked immunosorbent assay. Among patients with FS 73% had antibodies to 5-HT, in contrast to only 19% of patients with acute EMS. However, 77% of the 13 EMS patients analyzed 2 years later had become anti-5-HT antibody positive during that time. Also the incidence of antibodies to Gm1 increased from 37% at acute onset to 69% in patients with chronic EMS (30%). The various antibodies were detected in only 18% of healthy controls. Serum 5-HT levels were decreased in patients with acute EMS compared to those with chronic EMS or FS. In patients with PSS they were significantly increased. It is concluded that EMS may have been developed in patients with FS who may have reacted in an allergic manner to a more immunogenic (“contaminated”) L-tryptophan.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Surgical endoscopy and other interventional techniques 8 (1994), S. 753-758 
    ISSN: 1432-2218
    Keywords: Absorbable clips ; Metallic clips ; Laparoscopic cholecystectomy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The use of hemostatic surgical clips is crucial in laparoscopic surgery. Metal clips can cause significant interference with computerized tomography, may have poor holding power, and may erode into important anatomic structures. Polymeric absorbable clips, which have advantages over metallic clips, are evaluated in this study. In vitro and in vivo studies were undertaken to evaluate the hold force, rate of degradation, tissue reactivity and safety of absorbable polymeric clips. Absorbable and titanium clips were applied across excised canine cystic ducts and both axial and transverse pull-off forces were measured. In the second phase, absorbable clips were implanted subcutaneously into male rats and the strength remaining within the clips was measured after 7, 10, 14, or 21 days. In phase 3, 30 pigs were randomized into six groups and each animal underwent a laparoscopic cholecystectomy. The cystic duct and artery were ligated with absorbable polymeric clips (experimental group) or titanium clips (control group). Animals were sacrificed at 7, 14, or 28 days and a celiotomy was performed. Intraabdominal adhesions were assessed and scored. The force required to dislodge the absorbable clip was significantly greater than for metallic clips for both axial and transverse forces. Absorbable clip strength retention decreased over time as expected with a retention of 11% original strength by the 21st day. Adhesions were highest when bile spillage occurred, but did not differ significantly between either clip type. Absorbable polymeric clips were hemostatically effective in this laparoscopic model and may offer advantages over metallic clips.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Analytical studies of the stresses on and within ultra high molecular weight polyethylene joint components suggest that damage modes associated with polyethylene fatigue failure are caused by a combination of surface and subsurface crack propagation. Fatigue crack propagation tests under mixed mode loading conditions were conducted on center-cracked tension specimens machined from extruded blocks of sterilized polyethylene in an attempt to determine how fatigue cracks change direction in this material. Cyclic testing was performed using a sinusoidal wave form at a frequency of 5 Hz and an R-ratio (minimum load/ maximum load) of 0.15. Specimens had the notch oriented perpendicular to the direction of applied load and at angles of 60° and 45° to the loading direction. Numerical analyses were used to interpret the experimental test and to predict the fatigue behavior of polyethylene under mixed mode conditions. It was found that all cracks eventually propagated horizontally, regardless of the initial angle of inclination of the notch to the direction of applied cyclic load. In fact, the extent of the curvilinear crack growth was quite limited. An effective range of cyclic stress intensity factor was calculated for correlation with the rate of crack growth. The results followed a Paris relation, with crack growth rate linearly related to a power of the range of stress intensity, for all three crack orientations. The numerical analyses adequately modeled the experimental fatigue crack growth results. © 1994 John Wiley & Sons, Inc.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability