Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1990-1994  (2)
  • Debrisoquine hydroxylation phenotype  (1)
  • cataract  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 44 (1993), S. 63-67 
    ISSN: 1432-1041
    Keywords: Mexiletine ; Debrisoquine hydroxylation phenotype ; pharmacokinetic ; variability
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary Marked interindividual variation has been observed in the pharmacokinetics of the antiarrhythmic agent mexiletine. The fact that its urinary excretion is dependent on urinary pH may account, in part, for such variation. The influence that genetic differences in hepatic metabolism of the debrisoquine-type may have on mexiletine pharmacokinetics was considered in this study. The pharmacokinetics and urinary excretion of mexiletine (250 mg administered intravenously) were investigated in 5 rapid extensive metabolisers (EM), 5 slow EM and 5 poor metabolisers (PM) of debrisoquine, under conditions of controlled urinary pH. Mexiletine disposition kinetics was found to be altered in PM individuals. These subjects showed higher total area under the curve (AUC), (15.7 versus 8.16 μg · h · ml−1) prolonged elimination half-lives (in serum and urine) (serum: 18.5 versus 11.6 h, urine: 19.2 versus 11.7 h) and lower total clearance values compared with EM (216 versus 450 ml · min−1). In this respect, slow EM individuals generally presented intermediate values of those pharmacokinetic parameters. A higher incidence of adverse-effects was also observed among slow EM and PM subjects. It is concluded that genetic differences in mexiletine oxidation of the debrisoquine-type have an influence on its observed pharmacokinetic variability. The clinical consequences are discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    International ophthalmology 14 (1990), S. 97-100 
    ISSN: 1573-2630
    Keywords: antilens antibodies ; immunoassay ; cataract ; uveitis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract A new technique measuring serum antoantibodies to lens proteins, employing antigen linked to magnetisable cellulose particles and fluorescent end-point detection, was used to examine patients with senile cataract and inflammatory eye disease. 40% of patients with senile cataract had antibodies to lens proteins, as did 28% of patients with heterochromic cyclitis and 20% of patients with uveitis, while there were no positive sera from patients with scleritis. The single patient with lens-induced uveitis had a high titre, but so did some patients with senile cataract. With the incorporation of a standard curve this technique offers a reliable quantitative assay for lens autoantibodies. It may provide a valuable tool for the investigation of pathogenet ic mechanisms in cataract and inflammatory eye disease.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...