Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 11
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 19 (1990), S. 286-294 
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The electrospray ionization (ESI) and plasma desorption (PD) mass spectra of over 20 peptides and proteins, with molecular weights (Mr) ranging between 1182 and 143000, have been directly compared. Both techniques produced molecular ions for the majority of materials studied; however, neither approach proved to be universally applicable. PD failed for a number of proteins that were successfully analyzed by ESI, including some of very high Mr. On the other hand, ESI failed for proteins that apparently could not acquire a sufficient number of positive charges to allow transmission through the quadrupole mass filter. A non-covalently bound adduct, ribonuclease S, did not survive either method intact and a simple glycoprotein, ribonuclease B, did not yield the expected molecular ion with either approach. The mass measurement accuracy of quadrupole ESI is five to tenfold better than obtained with a commercial time-of-flight PD mass spectrometer. Furthermore, ESI's superior mass resolution (with quadrupole mass spectrometers) will prove to be particularly helpful for the characterization of mixtures of closely related materials. Sensitivity was only compared qualitatively but is highly compound dependent with both techniques. In favorable cases, ESI spectra can be obtained on low femtomolar quantities of proteins while PD typically requires several hundred femtomoles to high picomoles, depending on a number of factors including Mr.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 12
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Herein, we present the first example of charge state specific facile gas-phase cleavage of an aspartic acid-methionine peptide linkage. This cleavage (Asp 75-Met 76) was observed in the α-chain of human adult hemoglobin (Hb) and was probed by electrospray ionization mass spectrometry. This specific conformational and/or charge density dependent dissociation was observed primarily in the [M + 11H]11+ and [M + 12H]12+ species. A mechanism involving an intramolecular proton transfer from the protonated carboxyl side chain of Asp 75 to the neighboring Met 76 residue yielding an anhydride moiety at the C-terminal of the Asp 75 is proposed. Dramatic differences in dissociation of [M + 13H]13+ and [M + 14H]14+ species were observed.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 13
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 4 (1990), S. 415-417 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: The aims of the investigation were to use the method of dynamically programmed scans to study in detail some tandem mass spectrometric characteristics of the ion-trap mass spectrometer and then to use the programs to investigate the possibility of performing benchtop gas chromatography/tandem mass spectrometry experiments on the standard instrument. In particular we have examined the effect of applying a DC ramp during the ‘tickle’ period as a means of broadening the range of resonant frequencies, thereby facilitating the tuning required to effect excitation.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...