Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Analytical chemistry 63 (1991), S. 1482-1487 
    ISSN: 1520-6882
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 3 (1989), S. 323-328 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: The plasma desorption (PD) mass spectra of several enzymes and proenzymes are reported. Chymotrypsin and chymotrypsinogen both yield usable PD mass spectra; however, the single-chain chymotrypsinogen exhibits better sensitivity and less fragmentation than the multi-chain chymotrypsin. Porcine pepsinogen contains 11 more basic residues (lysine and arginine) than porcine pepsin, but this does not lead to an increase in positive ion response. In fact, the additional basic residues may hinder response by increasing the strength of the interaction between the protein and the nitrocellulose surface. A series of subtilisins showed comparable PD mass spectrometric, response despite the fact that they differ considerably in primary sequence. Finally, PD mass spectrometry was used to correct the previously reported mass of a heat-stable protease, a value that we found to be in error by almost 5000 Da.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 3 (1989), S. 46-50 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 4 (1990), S. 24-29 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: A simple method for off-line coupling of desorption mass spectrometry and capillary-zone electrophoresis (CZE) is described. Use of a “porous glass joint”, near the cathodic end of the CZE column, facilitates fraction collection in a manner similar to that used with liquid chromatography. This method allows independent optimization of both the CZE and mass spectrometry parts of the experiment. It is directly applicable to a number of desorption mass spectrometry methods (including plasma desorption (PD) and UV laser desorption (LD)). In the present study, PD mass spectrometry was used for eluant characterization. The fraction collection procedure is described, as is mass transfer through the porous glass joint. Detection limits are discussed and the approach is illustrated by analysis of a simple mixture of bradykinin derivatives. Finally, a brief comparison to current on-line CZE/mass spectrometric methods is presented.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 19 (1990), S. 286-294 
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The electrospray ionization (ESI) and plasma desorption (PD) mass spectra of over 20 peptides and proteins, with molecular weights (Mr) ranging between 1182 and 143000, have been directly compared. Both techniques produced molecular ions for the majority of materials studied; however, neither approach proved to be universally applicable. PD failed for a number of proteins that were successfully analyzed by ESI, including some of very high Mr. On the other hand, ESI failed for proteins that apparently could not acquire a sufficient number of positive charges to allow transmission through the quadrupole mass filter. A non-covalently bound adduct, ribonuclease S, did not survive either method intact and a simple glycoprotein, ribonuclease B, did not yield the expected molecular ion with either approach. The mass measurement accuracy of quadrupole ESI is five to tenfold better than obtained with a commercial time-of-flight PD mass spectrometer. Furthermore, ESI's superior mass resolution (with quadrupole mass spectrometers) will prove to be particularly helpful for the characterization of mixtures of closely related materials. Sensitivity was only compared qualitatively but is highly compound dependent with both techniques. In favorable cases, ESI spectra can be obtained on low femtomolar quantities of proteins while PD typically requires several hundred femtomoles to high picomoles, depending on a number of factors including Mr.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...