Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 11
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Crown ether polysiloxane phases ; Capillary columns
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Two crown ethers, di(tert-butylbenzo)-propyl-15-crown-5 polysiloxane (PSO-DTB-15C5) and dibenzo-propyl-15-crown-5 polysiloxane (PSO-DB-15C5) have been synthesized and coated onto fused-silica capillary columns. The chromatographic characteristics, including column efficiency, polarity, phase transition temperature, operating temperature range and selectivity, were studied. Excellent selectivity was obtained for the separation of polar position isomers, especially phenol and dinitrotoluene isomers. The separation mechanism is discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 12
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 35 (1990), S. 976-982 
    ISSN: 0006-3592
    Keywords: Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: The concept of pore size distribution is incorporated into the Clark model of enzyme immobilization in the present study. This refined model predicted that in the case of small harmonic pore radius with the same surface area and porosity of the support, more enzyme could be loaded in a support with nonuniform pores than that with uniform pores. In comparing the enzyme loading efficiency of the support with two different pore size distributions, the one with Gaussian distribution had the greater amount of enzyme immobilized than the other one with Rajagopalan's distribution. Furthermore, more enzyme could be loaded in a support with wider Gaussian pore size distribution than that with narrower distribution. The immobilized enzyme profile in the solid support with pore size distribution displayed a stepwise pattern which differed appreciably from the sigmoidal profile predicted for the support with uniform pore size. This stepwise enzyme distribution profile became sigmoidal with decreasing hT or increasing k. The new model could be used for designing protocols for an enzyme immobilization process.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 13
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 40 (1992), S. 1115-1118 
    ISSN: 0006-3592
    Keywords: microencapsulation ; poly(vinylamine) ; cell culture ; mechanical strength ; erythropoietin ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Poly(vinylamine) was synthesized and used to replace poly-L-lysine in forming microcapsule with alginate. Test results indicated that capsules with good mechanical strength and permeability could be obtained under the controlled treatment conditions of poly(vinylamine) and alginate. Application of the current microcapsular system to cell culture was demonstrated by the usage of erythropoietin- (EPO-) producing IW32 mouse erythroleukemia cells. The encapsulated IW32 cells grew to a density of 8 × 107 cells/mL, two times that found in the corresponding poly-L-lysine/alginate capsules. The EPO accumulation inside the microcapsule with the current encapsulation system was also higher. A concentration of 7.3 U/mL was attained as compared to 4.3 U/mL in the poly-L-lysine/alginate microcapsule. © 1992 John Wiley & Sons, Inc.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 14
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 39 (1992), S. 1128-1132 
    ISSN: 0006-3592
    Keywords: lipolytic rates ; hydrolysis ; tributyrin ; Candida rugosa ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: A dramatic change of the reaction rate was observed for the lipase-catalyzed hyrolysis of tributyrin in a batch reactor. Immediately after the addition of the enzyme, the lipolysis rate increased continuously until a maximal reaction rate was reached. The duration of the induction was mainly controlled by the bulk enzyme concentration and the reactor stirring speed. The reaction rate dropped sharply after reaching its maximal value. The lipolysis decayed at a rate of about 0.012 min-1, and was not affected by changes of the stirring speed. This decay was attributed to the fast deactivation of the surface-adsorbed lipase, and possibly to the extremely slow desorption of the inactivated species. For reaction time longer than 120 minutes, the lipolysis decreased at a much slower rate. Several mechanisms for the decay of the lipolysis rate were discussed.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 15
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 40 (1992), S. 446-449 
    ISSN: 0006-3592
    Keywords: urea sensor ; plasma reaction ; poly(propylene) membrane ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Urease was immobilized on the plasma-aminated surface of a hyfrophobic poly(propylene) (PP) membrane. This membrane, with urease matrix on one side while maintaining its original hydrophobic property on the other, was used to construct the urea sensor. The new urea sensors had response sensitivities ranged from 19 mV/decade to 30 mV/decade depending on the conditions of the plasma reaction. The enzyme electrode using single membrane gave a shorter response time as compared to the corresponding conventional electrode employing two seperate PP membranes. The sensitivity of the enzyme electrode increased with increasing buffer pH and reached a maximal level (40 mV/decade) at pH 7.6. The response sensitivity of the electrode was not affected by the change of buffer strength. Deamination of the plasma-modified hydrophobic PP membrane did not occur in aqueous environment judging from the stability of the urea electrode up to 12 days of operation. © 1992 John Wiley & Sons. Inc.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 16
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 1 (1990), S. 321-327 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: An aqueous humor draining device, with size comparable to that of the Krupin tube, was constructed by using poly-HEMA material. Deposits were found on the surface of poly-HEMA when contacted in vitro with the aqueous humor of the rabbit's eye. A fibrous structure, probably composed of proteins and other macromolecules, developed on poly-HEMA surface in 15 days after the draining device was implanted into the rabbit's eye. The draining device was still in function 250 days after its implantation. SEM analysis of the retrieved poly-HEMA draining device indicated that the poly-HEMA tube opening was not blocked by any substance. These results suggest that poly-HEMA could be used as a biomaterial for construction of the aqueous humor draining device to relieve the intraocular pressure of glaucoma patients. Its long-term application awaits further investigation.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 17
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 46 (1992), S. 1967-1972 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: The copolymers of poly[HEMA-co-(PVA-AA)] and poly[HEMA-co-(PVA-MA)] were synthesized and characterized. The presence of PVA-AA in the copolymer increased the mechanical strength but decreased the water content of the material. The presence of PVA-MA, on the other hand, caused a decrease of mechanical strength and an increase of water content. The ionization of acidic group in poly[HEMA-co-(PVA-MA)] resulted in the swelling of the copolymer, and the swelling extent was controlled by the change of pH. Both copolymers have great potential in biomedical application. © 1992 John Wiley & Sons, Inc.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...