Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 75 (1994), S. 1098-1101 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Raman spectra of n-type gallium nitride with different carrier concentrations have been measured. The LO phonon band shifted towards the high-frequency side and broadened with an increase in carrier concentration. Results showed that the LO phonon was coupled to the overdamped plasmon in gallium nitride. The carrier concentrations and damping constants were determined by line-shape fitting of the coupled modes and compared to values obtained from Hall measurements. The carrier concentrations obtained from the two methods agree well. As a result, the dominant scattering mechanisms in gallium nitride are deformation-potential and electro-optic mechanisms.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1041
    Keywords: S-mephenytoin 4-hydroxylase ; HPLC assay ; Human liver microsomes ; pharmacogenetics ; oxidation polymorphism
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary We have developed a simple HPLC assay to measure the activity of S-mephenytoin 4-hydroxylase in human liver microsomes, and have assessed its practical applicability by determining the kinetic parameters of the enzyme in 10 different human liver samples. The recovery of 4-hydroxymephenytoin and phenobarbital (the internal standard) after the precipitation of microsomal protein was almost complete, and the coefficients of variation for the intra-and interassay measurement of S-mephenytoin 4-hydroxylase activity were 〈6.4 and 8.0%, respectively. Eadie-Hofstee plots for the formation of 4-hydroxymephenytoin gave a straight line for all of the 10 samples studied. There was large interindividual variability in the kinetic parameters estimated: 4.6- (36 to 166 μM), 11.8- (0.9 to 10.6 nmole/mg protein/h) and 30.1-times (0.10 to 3.01 μl/mg protein/min) for Km, Vmax and Vmax/Km, respectively. The mean (±SD) Km, Vmax and Vmax/Km were 72.4±40.4 μM, 4.23±2.88 nmole/mg protein/h and 1.33±1.02 μl/mg protein/min, respectively. Thus, the assay was sufficiently accurate and reproducible to permit estimation of the kinetic parameters of S-mephenytoin 4-hydroxylase in human liver microsomes, and it appears to be applicable to an in vitro study of the possible involvement of S-mephenytoin-type oxidation polymorphism in drug metabolism.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Journal of thermal analysis and calorimetry 37 (1991), S. 1657-1663 
    ISSN: 1572-8943
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Die von verschiedenen Autoren veröffentlichten Resultate über die thermische Zersetzung von Silbercarbonat, Ag2CO3, sind widersprüchlich. In der vorliegenden Arbeit wurde der Zersetzungsmechanismus mittels unterschiedlicher analytischer Methoden aufgeklÄrt: Differenzthermische Gasanalytik in strömendem Helium, Kohlendioxid sowie Sauerstoff mit und ohne eine P2O5-Falle oder eine KOH-Falle, DTA-TG in strömendem CO2 und Hochtemperatur-Röntgendiffraktion in strömendem CO2. Die Gasentwicklung bei ca. 200
    Notes: Abstract Conflicting results have been reported by different workers on the thermal decomposition of silver carbonate, Ag2CO3. In the present study, the decomposition mechanism was elucidated by various analytical methods; gas analysis (differential thermal gas analyses) in helium, carbon dioxide and oxygen flows with and without a P2O5 trap or a KOH trap, DTA-TG in a carbon dioxide flow and high-temperature X-ray diffraction analysis in a carbon dioxide flow. The gas evolution at ca. 200
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...