Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1985-1989  (1)
  • 1975-1979  (1)
  • 1935-1939
  • Automation  (1)
  • Hyperplasia  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Archives of dermatological research 277 (1985), S. 457-465 
    ISSN: 1432-069X
    Keywords: Epidermis ; Hyperplasia ; TPA ; Stereology ; Morphometry ; Tumor promotors
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary 12-O-Tetradecanoylphorbol-13-acetate (TPA)-treated adult epidermis as well as untreated fetal and adult epidermis were investigated to elucidate the effect of TPA in terms of cell differentiation using techniques of ultrastructural stereology. Twenty-four hours after a single application of TPA, the treated epidermis was characterized by involutional changes, i. e., increased volume density of intercellular spaces and of mitochondria, vacuoles, and cytoplasmic ground substance in the basal layer. However, 48 h after application, the TPA-treated epidermis was very similar to fetal epidermis, i. e., high volume density of nuclei ribosomes, rough endoplasmic reticulum, membrane-coating granules, and keratohyalin granules, and low volume density of bundled filaments in the upper layers. These stereological data indicate that the changes observed 48 h after TPA treatment were related not only to increased cell proliferation but also to inhibition of cell differentiation expressed as a reversion of the adult differentiation patterns and the acquisition of fetal characteristics in all epidermal layers.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Pflügers Archiv 381 (1979), S. 11-14 
    ISSN: 1432-2013
    Keywords: Split-drop micropuncture ; Computers, digital ; Automation ; Image analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract A technique is described for rapid and reproducible analysis of split-drop micropuncture sequences recorded on film. Automatic identification of the droplet menisci in each cine frame, and subsequent evaluation is performed by a computerised T.V. image analysis system. In comparison with a more conventional technique, the improvement in reproducibility of the analysis is achieved without loss of accuracy and is accompanied by a three fold increase in speed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...