Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 0006-3525
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The conformation and internal dynamics of supercoiled pUC 8 DNA (2717 bp) are examined by dynamic light scattering, and the magnitude and uniformity of its torsional rigidity are determined using time-resolved fluorescence polarization anisotropy of intercalated ethidium dye. Neither measurement gives any indication of an appreciably reduced bending or twisting rigidity, or anomalously rapid internal motions. For 31P, in supercoiled pUC 8, we measure T2 = (2.0 ± 0.5) × 10-3 s. This lies within the range of present theoretical estimates obtained using normal rigidities. The proton linewidths observed for pUC 8 and pBR322 (4363 bp) DNAs are within a factor of 2-3 of those similarly estimated assuming ordinary rigidities.According to Bendel, Laub and James [(1982) J. Am. Chem. Soc. 104, 6748-6754], supercoiled pIns36 DNA (7200 bp) exhibits an astonishingly long T2 = 1.17 s for 31P, a slowest rotational relaxation time, τ = 5 × 10-9 s, and an enormously reduced bending rigidity. Serious questions raised by these findings are examined here. The 5 × 10-9 s slowest rotational relaxation time is shown to be physically inadmissible.The nmr relaxation theory developed previously by Allison, Shibata, Wilcoxon, and Schurr [(1982) Biopolymers 21, 729-762], is modified to incorporate new results for deformable filaments, which directly introduce the highly nonexponential tumbling correlation function for reorientation of the local helix axis. Essential requirements for a complete calculation of R2, including estimation of the tumbling correlation function and evaluation of the still unknown DIP/CSA cross-term, are described in detail. Slow coil-deformation modes analogous to the Rouse-Zimm modes of linear DNAs are shown to make an important, if not dominant, contribution to the R2 relaxation rate. Geometrical parameters in the theory are chosen to provide good agreement with literature data for 600-bp linear DNA. Using this theory and an informed guess for the tumbling correlation function, we find that the 31P-nmr relaxation data of Bendel et al., if correct, necessarily impose on their DNA one or more extreme properties, such as enormously reduced bending or twisting rigidities. In contrast, the same theory yields reasonable agreement with the T2 reported here for 31P in supercoiled pUC 8 DNA when its rigidities are assumed to be quite ordinary.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0887-6134
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Combined packed column supercritical fluid chromatography/mass spectrometry has been effected using a thermospray ion source in the filament-on mode. If organic modifiers are used with carbon dioxide as the supercritical mobile phase, chemical ionization mass spectra are obtained. With carbon dioxide electron impact type mass spectra are obtained. The potential of the system is illustrated with studies of mixtures of carbamate and organochlorine pesticides and a crude ergot fermentation extract.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 0887-6134
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A conventional bore liquid chromatograph has been interfaced to quadrupole and magnetic sector mass spectrometers configured for fast atom bombardment ionization via a continuous flow FAB probe. It is shown that post-column addition of FAB matrix and in-line ultraviolet detection facilities do not significantly compromise chromatographic integrity and that high quality mass spectra are obtainable from such FAB LC/MS studies.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 0887-6134
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The collision-induced dissociation mass spectrum, observed with a hybrid tandem instrument, of the ammonia chemical ionization protonated molecular ion of chloramphenicol was used for the detection of residues of the drug in biological samples. The extracted oil from fish was subjected to a rapid clean-up on a pre-packed silica gel cartridge prior to non-chromatographic tandem mass spectral analysis. Fat extracted from milk was analysed directly by on-line combined high-performance liquid chromatography/tandem mass spectrometry with rapid elution of chloramphenicol. Identification was on the basis of agreement of the daughter ion spectra obtained from sample extracts with that of the chloramphenicol standard. Detection was unambiguous at 0.5 mg kg-1. The sensitivity advantage normally expected with multiple reaction monitoring was not achieved owing to the effect of neutral noise phenomena.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part A: Polymer Chemistry 27 (1989), S. 4205-4226 
    ISSN: 0887-624X
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Synthetic procedures for preparation of terminally functionalized linear ethylene oligomers are described. The preferred synthetic method is anionic oligomerization of ethylene with n-butyllithium-tetramethylethylenediamine and electrophilic substitution of the living oligomer so-formed. Conditions and procedures for subsequent chemistry to elaborate the end groups of these oligomers are described. These procedures afford strictly linear ethylene oligomers which contain a wide variety of end groups and which range in molecular weight from 1000 to 4500 (Mn). The product oligomers were characterized spectroscopically as toluene-d8 solutions at 110°C using multinuclear NMR, FT-IR, fluorescence, and UV-visible spectroscopies as appropriate. Alternative stepwise approaches to such oligomers are also discussed.
    Additional Material: 1 Tab.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 18 (1972), S. 393-401 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Liapunov analysis techniques employing a general quadratic functional are used to derive stability conditions for tubular reactor systems. The adiabatic tubular reactor without axial dispersion is shown to be locally stable, which excludes the possibility of multiple steady states, and the reactor with axial dispersion is proven locally stable if a condition involving only system parameters and steady state values is satisfied. Peclet numbers for heat and mass transfer are not specified equal for the latter proof.Results of simulation studies are used to confirm the validity of the derived stability condition, and it is shown that the parametric region of multiplicity is quite well defined. For the nonlinear equations, single steady state cases appear to possess nonuniform stability.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Bioluminescence and Chemiluminescence 1 (1987), S. 165-171 
    ISSN: 0884-3996
    Keywords: Polymorphonuclear leukocytes (PMNL) ; oxidation ; thiol groups ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: Luminol-dependent chemiluminescence and thiol group oxidation of glutathione and human serum albumin were measured in order to demonstrate whether the inhibition of polymorphonuclear leukocyte chemiluminescence by albumin was attributable to thiol group oxidation. We have shown that: 1thiol groups on glutathione and albumin are oxidized by PMNL stimulated by soluble and phagocytic stimuli;2thiol group oxidation in albumin and glutathione did not correlate with the inhibitory effects of these substances on luminol-dependent chemiluminescence with respect to time course, magnitude, effects of known scavengers or extracellular activity. It was therefore concluded that thiol group oxidation was not the cause of albumin inhibition of luminol-dependent chemiluminescence;3a metastable oxidant was identified after PMNL activation which was capable of oxidizing thiol groups but unable to elicit chemiluminescence form luminol.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 12 (1985), S. 616-622 
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Non-volatile nitrosamines exemplified by nitroso amino acids, -dipeptides, -oxazolidines and -thiazolidines have been analysed by moving belt liquid chromatography/mass spectrometry (LC/MS) and spectra obtained by ammonia chemical ionization. Optimal conditions such as source temperature, source pressure and belt vaporizer temperature have been established. Interface degradation involving decarboxylation and denitrosation was experienced but could be alleviated to some extent by deactivation of the polyimide belt by silylation.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Collisionally activated dissociation mass spectra, observed with a hybrid tandem instrument, of the chemical ionization protonated molecular ions of sulphonamide drugs have been used as the basis of a rapid screening procedure for these drugs in crude extracts of pig's kidney by scanning to detect the parents of a characteristic daughter fragment. Extracts were introduced without chromatography by a moving belt interface. Detection limits of 0.1 mg/kg were achieved. Confirmation was made by obtaining daughter ion spectra of the protonated molecular ions. Multiple reaction monitoring with a stable isotope analogue as internal standard permitted the quantification of targeted compounds with high sensitivity and precision.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 14 (1970), S. 2469-2479 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: The automatic endless belt polymer fractionator utilizes a continuous application and multistage extraction technique. A thin coating of polymer deposited on a slowly moving endless belt which passes through a series of solvent-nonsolvent mixtures of increasing solvent strength is fractionally dissolved. Discussion includes the description of the construction of the apparatus, details and results of fractionations of Neoprene W and polytetramethylene ether glycol, fractionation techniques and subsequent work-up of the fractions, “large scale” preparative fractionations, and general performance characteristics.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...