Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1985-1989  (3)
  • 6-thiouric acid  (1)
  • Analytical Chemistry and Spectroscopy  (1)
  • Autocorrelation  (1)
Material
Years
Year
  • 1
    ISSN: 0030-493X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Extensive networks of metastable ions link the major peaks in the electron impact mass spectra of two crown ethers containing 2,6-pyrido units. High-resolution mass measurements and the metastable peaks allow the elucidation of the fragmentation pathways. The spectra are influenced more by the presence of aromatic substituents than by the 2,6-pyrido units.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1041
    Keywords: azathioprine ; 6-thiouric acid ; 6-mercaptopurine ; renal transplantation ; pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The immunosuppressive activity of azathioprine (AZA) is unpredictable and depends on the formation of intracellular thiopurine ribonucleotides. However, the quantification of these active thiopurines presents difficult analytical problems. It has recently been postulated that plasma concentrations of 6-thiouric acid (6-TU) and 6-mercaptopurine (6-MP), metabolites of AZA, may provide more readily measurable indices of the pharmacologic activity of AZA. In order to evaluate the utility of 6-TU and 6-MP plasma concentrations in monitoring AZA therapy, we studied their pharmacokinetics in 6 renal transplant patients, and their in vitro immunosuppressive potency in a mixed lymphocyte proliferation assay. A peak plasma 6-TU concentration of 710.7 ng/ml was observed at 3.8 h after oral dosing. Good correlation was observed between the elimination t1/2 of 6-TU and serum creatinine, and between AUC over 24 h and serum creatinine. However, we did not observe a second peak in plasma 6-TU concentration that could be attributed to the degradation of active AZA metabolites. 6-MP plasma concentrations in the patients were low (mean peak concentration 36.0 ng/ml) and rapidly disappeared within 8 h. In vitro immunosuppressive activity could not be demonstrated for 6-TU over a concentration range of 1.25 ng/ml to 0.25 mg/ml. We conclude that 6-TU is pharmacologically inert and is primarily eliminated by the kidneys. Our findings currently do not support the use of plasma concentrations of 6-TU or 6-MP to monitor AZA therapy. In order to optimize AZA therapy, analytical techniques that are technically feasible and that can directly quantify the active intracellular thiopurines are being explored.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 25 (1987), S. 241-249 
    ISSN: 1741-0444
    Keywords: Analysis ; Autocorrelation ; Defibrillation ; Performance ; Regression ; Signal ; Ventricular fibrillation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract The paper investigates quantitative differences in the signal characteristics of ventricular fibrillation (VF) and other cardiac arrhythmias. The analysis procedure comprises two steps: calculation of a short-term autocorrelation function (ACF) followed by a regression test on a plot of peak magnitudes of the ACF against lag values (the ACF/lag plot). We detect VF by testing the hypothesis that the ACF/lag plot of VF does not pass a linear regression test. Analysis of 31 separate episodes (of VF and other ventricular arrhythmias), each comprising three successive segments of 1·5s each produced the following results: (1) 100 per cent sensitivity (Se), 62 per cent specificity (Sp) and 74 per cent test efficiency (TE) after analysis of the first segment; (2) 100 per cent Se, 86 per cent Sp and 90 per cent TE after the second segment; and (3) 100 per cent Se, 100 per cent Sp and 100 per cent TE after the third segment. This method quantifies the notion that VF signals are nonperiodic with a random amplitude distribution, whereas ventricular tachycardia (VT) signals are usually periodic with more uniform amplitude distributions. Accurate discrimination and identification of VF can be very important in intensive-care settings, as well as in the design of automatic cardioverters and defibrillators.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...