Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1985-1989  (10)
  • Chemistry  (7)
  • Life and Medical Sciences  (3)
  • Cell & Developmental Biology  (2)
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim [u.a.] : Wiley-Blackwell
    Materials and Corrosion/Werkstoffe und Korrosion 40 (1989), S. 175-181 
    ISSN: 0947-5117
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: Einfluß von Chlorwasserstoff auf die Korrosion einer FeCrAlY-Legierung in einer simulierten KohlevergasungsatmosphäreEie Chrom-Aluminium-Yttrium-Stahl wurde einer simulierten Kohlevergasungsatmosphäre ausgesetzt die 1000 ppm bzw. 2200 ppm Chlorwasserstoff enthielt und deren Temperatur 450 °C betrug. Durch Erhöhen des Chlorwasserstoffgehalts werden die Reaktionsgeschwindigkeit erhöht und die Mikrostruktur sowie die Zusammensetzung des Korrosionsprodukts beträchtlich verändert. Für diese Ergebnisse werden versuchsweise Mechanismen postuliert, nach denen Metallchloride über die Gasphase transportiert werden.
    Notes: An iron chromium aluminium yttrium steel was exposed to a simulated coal gasifier atmosphere containing 1000 ppm and 2200 ppm hydrogen chloride at 450 °C. Increasing hydrogen chloride content was found to accelerate reaction rates, and significantly alter the microstructure and composition of the corrosion product. Tentative explanations for these results, involving vapour phase transport of metal chlorides are proposed.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    The @Anatomical Record 213 (1985), S. 505-513 
    ISSN: 0003-276X
    Keywords: Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: Scanning electron microscopy of corrosion casts of blood vessels permits detailed and accurate study of the microcirculation. The present study examined the renal microvasculature of the rainbow trout, Salmo gairdneri. The conventional picture of a glomerulus with one afferent arteriole was common, but glomeruli were often supplied by two afferent arterioles. In the majority of these, the intrarenal artery gave rise to a single afferent arteriole that branched to form two smaller vessels before reaching the glomerulus. Glomeruli with two afferent arterioles that arose independently from the intrarenal artery also occurred. The majority of glomeruli had a single efferent arteriole, but a proportion of glomeruli had two efferent arterioles. Efferent arterioles were smaller in diameter than the afferent arterioles. The glomerular capillaries were arranged in lobules, with few anastomoses between lobules, so that, for glomeruli with two afferent or two efferent arterioles, vascular perfusion and thus filtration within discrete lobules is probable.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Clinical Anatomy 2 (1989), S. 17-27 
    ISSN: 0897-3806
    Keywords: wrist position influence ; fast isometric contractions ; motor control ; human hand muscles ; Life and Medical Sciences ; Miscellaneous Medical
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: The influence of wrist position on the motor control of intrinsic and extrinsic hand muscles during the performance of fast isometric precision-grip contractions was evaluated. Ten male and female subjects, aged 17-28 years, attempted to produce accurately 75%, 50%, 25%, and 10% of a predetermined maximum criterion force level with the wrist in the flexed, functional, and extended positions. Feedback on the accuracy of each contraction was provided by a visual error display after each trial. Trials selected for analysis fell within ± 5% error of the required force level. Surface electromyograms were recorded from the first dorsal interosseous, adductor pollicis, abductor pollicis brevis, common flexor muscles and the extensor digitorum. Wrist position was shown to influence significantly the integrated electromyographic values representing the activity of the first dorsal interossous but not the adductor pollicis. Significant alterations in the onset time of the antagonist extensor digitorum were also detected. On the basis of the these results we suggest that the intrinsic muscles of the hand can be classified as either wrist position dependent or independent.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Polymer Science: Polymer Letters Edition 27 (1989), S. 515-525 
    ISSN: 0887-6258
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    Surface and Interface Analysis 9 (1986), S. 255-257 
    ISSN: 0142-2421
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    Surface and Interface Analysis 9 (1986), S. 253-254 
    ISSN: 0142-2421
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    Surface and Interface Analysis 7 (1985), S. 74-78 
    ISSN: 0142-2421
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: A scanning system has been installed on a Cameca IMS 3f ion microscope. The system has been invaluable for alignment of secondary ion extraction to the centre of the crater during depth profiling, detection of inclusions and lateral inhomogeneities during depth profiling and compensation of charging of insulators using an electron flood gun. Limitations of the standard gun have become apparent.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 0142-2421
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: Recent experiments have shown that secondary ion mass spectrometric (SIMS) measurements of insulator surfaces can be greatly facilitated by the use of a charged aperture located immediately above the analysis area (the ‘specimen isolation technique’). This allows the surface potential within the aperture area to be stabilized. Charging is stabilized when the potential difference between the surface and the aperture becomes large enough that excessive charge, in the form of secondary electrons, is drained away from the surface to the aperture. The potential difference generated on such insulating surfaces can be measured experimentally by varying the voltages applied to the electrostatic analyzer to measure the secondary ion intensity as a function of kinetic energy. Such measurements have been carried out on a Cameca IMS-3F instrument for a range of aperture dimensions and for different primary and secondary ions. The surface potential can be stabilized at a potential readily measurable by the electrostatic analyzer for both O- and Cs+ ion beams. The mechanism for this stabilization has been analyzed through calculations of two dimensional contours for the region around the specimen holder. For surfaces with a very high charging potential (〉600 V), potential wells which can trap ions of low kinetic energy develop near the surface. Element and oxide secondary ion kinetic energy distribution curves, taken under specimen isolation conditions, which differ from those obtained under normal non-charging SIMS conditions, are evidence for such ion trapping.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Electrophoresis 7 (1986), S. 239-239 
    ISSN: 0173-0835
    Keywords: Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Electron Microscopy Technique 8 (1988), S. 225-226 
    ISSN: 0741-0581
    Keywords: Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Natural Sciences in General
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...