Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1985-1989  (3)
  • in vitro fertilization (IVF)  (2)
  • Chemical Engineering  (1)
  • Keywords Type II diabetes
  • 1
    ISSN: 1573-7330
    Keywords: human serum ; frozen storage ; in vitro fertilization (IVF)
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract This study retrospectively compared the success of in vitrofertilization (IVF) among patients whose gametes had been incubated either in medium supplemented with freshly prepared pooled serum (331 cases) or in pooled serum which had been stored at −20°C prior to use (728 cases). Frozen stored serum was as effective as fresh serum with regard to the proportion of oocytes which fertilized and embryos which implanted and was not associated with any increased incidence of fetal loss during postimplantation development.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1573-7330
    Keywords: growth rate ; in vitro fertilization (IVF) ; pregnancy prediction ; embryo quality
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Two systems for measuring embryo development in vitro were evaluated. One was a 1–4 scale based on a subjective evaluation of embryo quality (EQ) from microscopic appearance. In addition, a formula for scoring embryo growth rate in vitro was developed. The embryo development rating (EDR) was based on the ratio between the time at which embryos were observed at a particular stage after insemination and the time at which they would be expected to reach that stage in a hypothetical “ideal” growth rate with a cell cycle length of 11.9 hr. Using this scoring system, “normally” growing embryos scored 100. This approach was aimed at partially normalizing the data and allowed all embryos to be analyzed similarly regardless of the time of observation. Analysis of 1539 embryo replacements resulting in 232 clinical pregnancies showed that both EDR and embryo-quality scores were of value in predicting success, with clinical pregnancy most likely to eventuate from a combination of moderate to good EQ scores (2–4) coupled with average or above-average growth rates (EDR scores from 90 to 129). Poor-quality and very slowly or very rapidly growing embryos were underrepresented in cycles that proceeded to pregnancy. These inferences were based on all embryos transferred (mean, 2.73 per transfer cycle), and they were substantiated by an analysis of 33 pregnancies resulting from replacement of a single embryo and from 18 pregnancies in which all embryos scored the same with both systems. EQ and EDR were significantly associated with each other and together provide a valuable guide in predicting pregnancy, in selecting embryos for freezing, and in monitoring day-to-day performance in the in vitro fertilization (IVF) program.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Stamford, Conn. [u.a.] : Wiley-Blackwell
    Polymer Engineering and Science 29 (1989), S. 907-910 
    ISSN: 0032-3888
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: A negative resist based upon photo-acid initiated cationic polymerization of an epoxy resin (1, 2) was reported in the early eighties with the advent of onium salts (3-5). An efficient acid generating onium salt, triphenylsulfonium hexafluoroantimonate (6), absorbs light in the deep UV producing acid upon direct photolysis in this region of the spectrum. The resin component of such a negative resist system must be optically transparent over the exposure wavelengths to obtain vertical image profiles. Another difficulty often encountered with crosslinking negative resists is swelling of the crosslinked matrix during development with organic solvents. This swelling manifests itself in distorted images and/or complete adhesion loss, especially when submicron features are involved. Our goal has been to address these problems and develop an organic developable deep UV resist capable of providing submicron images. Optically transparent commercial resins, styrene-allyl alcohol copolymers, have been converted to glycidyl ethers, thereby providing cationically polymerizable functionalities. Careful choice of the resin was made to obtain reactive ion etch resistance, thermal stability, good adhesion, and coating properties. The synthetic procedure and characterization of the epoxy resin will be presented. The effect of the molecular weight distribution upon swelling during development and general solubility properties also will be discussed. Resist formulations exhibited sensitivities of 19 to 30 mJ/cm2 on a Perkin Elmer 500 in the deep UV (UV2) mode. The electron beam sensitivity is 3 to 5 μC/cm2 at 20 KeV. Submicron images have been generated in both optical and electron beam lithography.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...