Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-069X
    Keywords: Glucose-6-phosphate dehydrogenase ; Dehydroepiandrosterone ; Mononuclear leukocytes ; Psoriasis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary The aim of the study was to determine a biochemical basis for the augmented oxidative metabolism found in mononuclear leukocytes (MNL) of patients with active psoriasis. Dehydroepiandrosterone (DHEA) is known to inhibit glucose-6-phosphate dehydrogenase (G-6-PDH). We determined the activity of G-6-PDH as well as the penetration and metabolism of DHEA — diminished plasma concentrations of which have been found in psoriatics previously — in 16 patients with active psoriasis and 16 controls. MNL in patients with psoriasis possessed 52% more (p〈0.05) G-6-PDH activity, based on cell number, and 34% more (p〈0.05) activity, based on soluble protein. No difference in DHEA penetration and metabolism in MNL was found between psoriatics and controls, in contrast with previous findings of reduced penetration and increased reduction in erythrocytes of psoriatics. We conclude that the enhanced G-6-PDH activity in MNL of patients with active psoriasis is not due to altered DHEA penetration or metabolism.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 33 (1989), S. 39-48 
    ISSN: 0006-3592
    Keywords: Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Various experimental procedures for the determination of transient characteristics with significant liquid film effects were tested. A comparison between transient characteristics obtained experimentally and those calculated from rational models indicates that all procedures but one give highly inconsistent results. Recalculation of transient characteristics with no liquid film (easily measured in the gas phase) to that with liquid film (occurring in viscous liquids) is recommended as well as the selected experimental procedure which yields consistent results in the situations where the steady-state probe reading is decreased up to one-half due to the liquid film.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 32 (1988), S. 482-490 
    ISSN: 0006-3592
    Keywords: Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Empirical equations used so for for computing kla in mechanically agitated aerated vessels agree well with the measured dependence of Kla on the power input of the stirrer and the superficial velocity of the gas. However, they do not fit the dependence of Kla on the physical properties of the liquid batch. From the data published so far it can be deduced that the equations suitable for the description of the dependence of kmola on the liquid physical properties must include some independent variable, which characterizes the rate of coalescence of the bubbles. About 400 experimental values of Kla were compared with those calculated from different relations. This comparison shows that the rate of coalescence for the aqueous electrolyte solutions is well described on the basis of the Gibbs theory of adsorption of the solute in the surface layer of the solution.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 33 (1989), S. 1406-1412 
    ISSN: 0006-3592
    Keywords: Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: A dynamic method is proposed for kla measurement in aerated and agitated reactors, in which a change in the total pressure in the reactor by approximately 20% leads to a simultaneous change in the oxygen concentration in all the bubbles in the dispersion. This procedure suppresses the influence of nonideal mixing of the gas phase on the kla value. Other dynamic methods so far used do not possess this advantage. They are based on a step change in oxygen concentration in the entering gas, where the interfacial nitrogen transport and the finite rate of the concentration change propagation into the individual bubbles in the dispersion can cause an error in the reported kla values of more than hundreds of percent. The reliability of the pressure method is tested by comparison both with the standard dynamic method, in which pure oxygen is absorbed in a liquid from which all other gas components were previously removed, and with the steady-state sulphite method. The signal of the oxygen probe used in the experiments must be independent of the pressure. A test for this in dependence is described. The pressure method is also suitable for large-scale reactors since the necessary pressure changes are sufficiently small and, morever, air can be used.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Chemical Engineering & Technology - CET 12 (1989), S. 213-217 
    ISSN: 0930-7516
    Keywords: Chemistry ; Industrial Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Important aspects of K1a measurement in agitated aerated vessels are briefly characterized from the standpoint of reliability of the measured data. An analysis of the shortcomings of dynamic methods for measuring the K1a is given. A new modification of the dynamic method is proposed, which excludes these inadequacies through a special experimental arrangement. This was verified by comparing the data with those obtained by an independent steady-state method. The new method can serve as a standard of reference, suitable for testing newly developed methods for K1a measurement. The initial response method was tested in this way in non-coalescent liquids, and shown to lead to errors of the order of hundreds of percent. K1a values obtained with the initial response method were found to depend strongly on the probe's location in the vessel.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...