ISSN:
0930-7516
Keywords:
Chemistry
;
Industrial Chemistry
Source:
Wiley InterScience Backfile Collection 1832-2000
Topics:
Chemistry and Pharmacology
,
Process Engineering, Biotechnology, Nutrition Technology
Notes:
Important aspects of K1a measurement in agitated aerated vessels are briefly characterized from the standpoint of reliability of the measured data. An analysis of the shortcomings of dynamic methods for measuring the K1a is given. A new modification of the dynamic method is proposed, which excludes these inadequacies through a special experimental arrangement. This was verified by comparing the data with those obtained by an independent steady-state method. The new method can serve as a standard of reference, suitable for testing newly developed methods for K1a measurement. The initial response method was tested in this way in non-coalescent liquids, and shown to lead to errors of the order of hundreds of percent. K1a values obtained with the initial response method were found to depend strongly on the probe's location in the vessel.
Additional Material:
3 Ill.
Type of Medium:
Electronic Resource
URL:
http://dx.doi.org/10.1002/ceat.270120129