ISSN:
1077-3118
Source:
AIP Digital Archive
Topics:
Physics
Notes:
MeV ion implantation in Si above a dose of 1014/cm2 leads to secondary defect formation in a buried layer, which is rather stable. Annealing of Si(100) implanted with 2.0 MeV B+ ions to a dose of 2.2×1014/cm2 has been investigated by means of cross-sectional transmission electron microscopy. After annealing at 900 °C for 15 min, dislocation loops elongated along [110] were found. A remarkable decrease in secondary defect formation has been observed if, in addition, 140 keV Si+ was implanted prior to annealing.
Type of Medium:
Electronic Resource
URL:
http://dx.doi.org/10.1063/1.102181
Permalink