Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1985-1989  (4)
Material
Years
Year
  • 1
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Community dentistry and oral epidemiology 15 (1987), S. 0 
    ISSN: 1600-0528
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Abstract Fibre optic transillumination (FOTI) has been employed during the course of a 3-yr clinical dentifrice trial which initially involved 3003 children. At the initial examination, a subgroup of 813 13-yr-olds, and at the following annual visit, 2247 14-yr-olds, were examined using a 150 W lamp and 0.5 mm diameter probe. Routine clinical and radiographic examinations were performed separately. Compared to the clinical scores for anterior teeth, FOTI detected an additional 64% of interproximal lesions at the first visit while, for the larger number of children at the second visit, the increase in lesion detection level using FOTI was 37%. For the posterior teeth the comparable figure at the second examination was 92%. When FOTI data were compared to radiographic data for more than 52 000 posterior interproximal surfaces, FOTI could only detect 17% of radiographic Grade 2 lesions and 48% Grade 3 lesions. Thus any assumption that FOTI diagnoses may be a substitute for bitewing radiography appears premature.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of oral rehabilitation 13 (1986), S. 0 
    ISSN: 1365-2842
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Measurements were made, using an acoustic transmission method, of the setting times of three visible-light curing sealants (two filled, one unfilled). Five commercially available visible-light polymerizing sources were tested with each material. Only three of the light sources gave setting times not significantly different from the manufacturers' recommended times for all three materials tested.The variation in microhardness with depth of sealant was measured to study the depth of polymerization of the sealants, all of which were adequate. The filled sealants had microhardness values greater than the unfilled sealant, at all depths studied.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of oral rehabilitation 13 (1986), S. 0 
    ISSN: 1365-2842
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Measurements were made of the spectral distribution of light emitted from five commercially available visible-light polymerization units. All emissions peaked between 400 and 500 nm but the ‘functional’ irradiance varied by a factor of 20 for the sources investigated. Timer checks revealed errors of up to 20%. Light output was plotted as a function of time and, after 60 s, varied from −15% to +38% of the initial level. The decrease in irradiance with distance from the end of the guide was such that irradiance at 20 mm was between 20% and 40% of that at 2 mm. The light distribution across the face of each light guide was investigated and significant inhomogeneities discovered. An ultraviolet light (UV) hazard assessment was performed and it was concluded that none of the light sources presented a hazard to the operator in normal use.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of oral rehabilitation 13 (1986), S. 0 
    ISSN: 1365-2842
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: As part of a laboratory evaluation, measurements of abrasion loss and tensile enamel–sealant bond strengths have been made on three visible light cured sealants (two filled, one unfilled), two chemically cured sealants (one filled and one unfilled) and an experimental sealant with alumina filler particles. A UV-cured filled sealant was used as a control. The unfilled sealants had abrasion loss approximately twice that of the filled commercial sealants. The experimental sealant, with filler content above 50%, had an abrasion loss approximately half that of the filled commercial sealants. The chemical cured sealants had bond strengths lower than the UV-cured control, while the bond strengths of the two visible light-cured filled sealants and the experimental sealant were not statistically different from either the unfilled visible light-cured sealant or from the UV-cured filled sealant.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...