Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1980-1984  (3)
  • 1970-1974
  • 1965-1969
  • Myoelectric control  (2)
  • Bacteriology of urine and renal calculus  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Urological research 12 (1984), S. 107-109 
    ISSN: 1434-0879
    Keywords: Infected urine ; Stone culture ; Bacteriology of urine and renal calculus ; Struvite calculus ; Oxalate calculus
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary The bacteriological status of the pre-operative urine, removed calculus and the pelvic urine was studied in 63 consecutive patients undergoing removal of intrarenal calculi. The overall infection rates in the pre-operative urine, removed calculi and pelvic urine were 29%, 38% and 30% respectively. In patients with staghorn calculi, 58% of patients had an infected pre-operative M.S.S.U., and 82.5% of removed calculi demonstrated significant bacterial growth, with Proteus mirabilis being the predominant organism isolated. In patients with single or multiple oxalate calculi, 17% had an infected pre-operative M.S.S.U., and 22% of removed calculi demonstrated a significant bacterial growth. The findings would indicate that the presence of a positive M.S.S.U. in a patient with a renal calculus is an indication for surgical removal.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 18 (1980), S. 65-69 
    ISSN: 1741-0444
    Keywords: Electrocutaneous stimulation ; Myoelectric control ; Prosthetics ; Sensory feedback
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract Progress in the development of a system to provide sensory feedback of the pinch force of an artificial hand is described. Design criteria relating to electrocutaneous stimulation and compatibility with myoelectric control are discussed. Details of a practical system, presently in use by two amputees prior to full-scale clinical evaluation, are presented.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 18 (1980), S. 287-290 
    ISSN: 1741-0444
    Keywords: Man-machine systems ; Multistate control ; Myoelectric control ; Prosthetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract A myoelectric control system is one in which the operation of a device is controlled by the electric potential produced by voluntary contraction of a muscle. The utilisation of a single muscle site for the 3-state control of a myoelectric prosthesis has proven beneficial for certain amputees. It has been proposed that a single muscle site could be used for 5-state control, perhaps for an elbow and hand. This paper presents a preliminary study of the error probability for 5-state control.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗