Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1980-1984  (2)
  • 1965-1969  (2)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    European journal of pediatrics 102 (1968), S. 62-70 
    ISSN: 1432-1076
    Keywords: Isocitratdehydrogenase ; Enzymuntersuchungen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Bei 312 erkrankten Kindern im Alter bis zu 12 Jahren wurde die Aktivität der Isocitratdehydrogenase (ICDH) im Serum ermittelt, um deren mögliche diagnostische Bedeutung für die Pädiatrie festzustellen. Dem Krankengut wurde ein Normalkollektiv von 176 gesunden Kindern gegenübergestellt. Die Normalwerte der ICDH-Aktivität im Serum bei Neugeborenen liegen zwischen 1,88 und 8,76 mU mit einem Mittelwert von 4,8±2,2 mU; bei Kindern bis zu 12 Jahren zwischen 0 und 5,13 mU mit einem Mittelwert von 2,21±0,91 mU. In 80% der Fälle von akuter Virushepatitis zeigte die Serum-ICDH Aktivitätserhöhungen bis zu 59,6 mU/ml, wobei das Ausmaß der Erhöhungen der ICDH bei akuter Virushepatitis keinen sicheren Schluß auf Schwere und Prognose der Erkrankung zuläßt. Der diagnostische Wert der ICDH bei Erkrankungen im Kindesalter liegt vor allem in den akuten Krankheitsverläufen (akute Virusmyokarditis oder Virushepatitis). Im Liquor cerebrospinalis gesunder Kinder war keine Aktivität nachweisbar, im pathologischen Liquor fanden sich unterschiedliche Erhöhungen, die keinen differentialdiagnostischen Rückschluß erlaubten.
    Notes: Summary Serum isocitric dehydrogenase (S-ICD) was determined in 176 healthy children and 312 children with various diseases. In healthy children, the normal value lies at 2.2 mU with a standard deviation of ±0,9 mU. The average value is depending on the age of the patients. In 80% of all cases of acute virus hepatitis the S-ICD showed an increase in activity, but no strict correlation between the increase in activity and the prognosis of the individual case could be found in children suffering from mucoviscidosis, myatonia dystrophica, and progressiv muscular dystrophy. An activity of the S-ICD in the liquor cerebrospinalis is only measureable in cases of meningitis, where an increase can be demonstrated. The diagnostic value of the determination of the S-ICD in pediatrics is limited to the acute stadium of diseases, where high activity can be found.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    European journal of pediatrics 102 (1968), S. 230-237 
    ISSN: 1432-1076
    Keywords: Isocitratdehydrogenase ; Erythrocytenenzyme bei Kindern
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Bei gesunden und kranken Kindern wurden intraerythrocytäre Enzyme unter besonderer Berücksichtigung der ICDH und G-6-PDH gemessen. Die Normalwerte für die ICDH liegen zwischen 14,2 und 42,1 mE/109 Erythrocyten (Höchstwert!), die der G-6-PDH zwischen 240 und 388,3 mE/109 Erythrocyten. Bis auf die Blutgruppenunverträglichkeit konnte bei keiner von uns erfaßten Erkrankung eine signifikante Änderung der ICDH oder G-6-PDH festgestellt werden. Auf das unterschiedliche Verhalten der Enzyme in Neugeborenenerythrocyten und in jungen Erythrocyten Erwachsener wurde nochmals hingewiesen, ebenso auf eine Korrelation zwischen G-6-PDH und ICDH, die statistisch verifiziert wurde.
    Notes: Summary ICD and glucose-6-phosphate dehydrogenase (G-6-PDH) were determined in healthy children as well as in children with various diseases. In healthy children the normal value for the ICD lies between 14.2 and 42.1 mE/109 erythrocytes. For the G-6-PDH the normal values are between 130.1 and 388.3 mE/109 erythrocytes with an average of 240.8 mE/109 erythrocytes. The normal values are significantly wide spread, they are also depending on the age of the examined children. In our cases no significant decreases in the intraerythrocytic activity of the two enzymes could be stated in children with various diseases. Various enzymatic results show that the erythrocytes of newborns and young children are more different from those of adults than previously assumed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Biotechnology letters 3 (1981), S. 303-308 
    ISSN: 1573-6776
    Source: Springer Online Journal Archives 1860-2000
    Topics: Process Engineering, Biotechnology, Nutrition Technology
    Notes: Summary Nikkomycins are nucleoside-peptide antibiotics, produced by Streptomyces tendae. In contrast to any biological evaluation, high-performance liquid chromatography provided the quantitation of five nikkomycin components from the culture filtrate of the fermentation broth.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 306 (1981), S. 212-232 
    ISSN: 1618-2650
    Keywords: Spurenanalyse ; Datenkonzentrierung, Datenverarbeitung
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary Statistical data evaluation in trace element analysis was mainly influenced by the Normal Law of Error, which is based on the assumption of a Gaussian normal distribution. Supposing that the analytical error of the trace element concentration is negligibly small compared with its true variations in nature, skew distributions may become more important than normal ones. Often, but not always, the lognormal distribution is a good approximation of the skew distribution. Careful investigation of the type of distribution before starting data evaluation in trace element analysis is still frequently overlooked today. In this Department, data concentration is performed on a routine basis by two programmes ZCH-2 and ZCH-3/1. They include a) investigation of the type of distribution by drawing the histogrammes, probability plot for normal and lognormal distribution as Hazen's straight lines, Kolmogorov-Smirnov- and Cramer- van Mises goodness-of-fit tests as well as skewness and kurtosis. Outliers of the normal distribution can be eliminated b) by t-, Nalimov's r-, Grubb's and Dixon's tests. c) As central values for data location, the arithmetic, geometric, and harmonic means and median are calculated. d) The dispersion around the mean is characterized by variance, standard deviation of a single value as well as the mean, relative coefficient of variation, mean deviation from the arithmetic mean, geometric standard deviation, range and 80% inter-decile range. Confidence intervals are given for the arithmetic mean, geometric mean and median. Typical problems of data concentration are the deviation from the normal distribution, comparison of different mean values, outlier elimination, concentrations below detection limit, homogeneity and heterogeneity of the data sample. They are discussed for examples of data series from one of the author's laboratories, e.g. trace element concentrations in air, lead content in dental calculus, toxic heavy metal leaching from ceramic ware and gamma dose rates from an area of higher natural radioactivity in the Federal Republic of Germany. As a conclusion, it is emphasized that the trace element analyst should overcome the “Mystery of the Normal and Quasi-normal Distribution” and include skew data distributions and their statistical treatment into his repertoire of routine procedures as well as in his way of thinking.
    Notes: Zusammenfassung Die statistische Beurteilung von Daten der Spurenelementanalyse war lange Zeit durch das Gesetz der Fehler-Normalverteilung geprägt, welches auf der Annahme einer Gaußschen Normalverteilung beruht. Wird der analytische Fehler der Konzentrationsbestimmung von Spurenelementen vernachlässigbar klein gegenüber den tatsächlichen Schwankungen in der Natur, dann werden schiefe Verteilungen häufig wichtiger als Normalverteilungen. Eine gute Näherung ist oft, allerdings nicht immer, die Lognormalverteilung. Der Spurenanalytiker übersieht häufig auch heute noch, vor Beginn der eigentlichen Datenbeurteilung den Typ der vorliegenden Häufigkeitsverteilung seines Datensatzes zu untersuchen. Die Datenkonzentrierung erfolgt in der hiesigen Zentralabteilung routinemäßig vor allem mit den Programmen ZCH-2 und ZCH-3/1. Darin wird der Typ der Datenverteilung a) durch Zeichnen der Histogramme, Auftragung als Hazens Gerade in Wahrscheinlichkeitskoordinaten für Normal- und Lognormalverteilung, den Kolmogorov-Smirnov- und Cramer-van-Mises-Anpassungstests sowie Schiefe und Wölbung beurteilt. Bei Quasi-Normalverteilungen können b) Ausreißer durch den t-, Nalimovs r-, Grubbs- und Dixon-Test eliminiert werden. Zentralwerte zur Lokalisierung des Datenkollektives sind c) arithmetisches, geometrisches und harmonisches Mittel sowie Median. Die Streuung um die Mittelwerte wird durch d) Varianz, Standardabweichung für Einzelwert sowie Mittel, relativen Variationskoeffizienten, geometrische Standardabweichung, Bereich und 80% Interdezil-Bereich charakterisiert. Zusätzlich werden Vertrauensbereiche für das arithmetische und geometrische Mittel und den Median berechnet. Als typische Probleme der Datenkonzentrierung werden die Abweichungen von der Normalverteilung, ein Vergleich verschiedener Mittelwerte untereinander, die Eliminierung von Ausreißern, die Behandlung von Konzentrationen unterhalb der Nachweisgrenze sowie Homogenität und Heterogenität der Datenkollektive behandelt. Dies wird an Datenreihen aus früheren Untersuchungen eines der Verfasser über Spurenelementkonzentrationen in der Luft, den Bleigehalt in Zahnstein, die Auslaugung toxischer Schwermetalle aus Keramikgeschirr und Gamma-Dosisleistungen aus einem Gebiet der Bundesrepublik mit höherer natürlicher Untergrundradioaktivität erläutert. Als wesentliches Ergebnis soll die Arbeit dazu beitragen, daß der Spurenanalytiker das „Mysterium der Normalverteilung“ überwindet und die Behandlung schiefer Datenverteilungen sowohl in das Repertoire seiner Routineuntersuchungen als auch in sein analytisches Denken aufnimmt. Um einen größeren Kreis von Spurenanalytikern anzusprechen, ist die Darstellung elementar gehalten.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...