Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • 1980-1984  (2)
  • Anemia, hemolytic  (1)
  • Complement, C3b  (1)
  • Dynasil 4000  (1)
  • 1
    Digitale Medien
    Digitale Medien
    Springer
    Annals of hematology 45 (1982), S. 249-259 
    ISSN: 1432-0584
    Schlagwort(e): Complement, C3b ; Hemoglobinuria, paroxysmal ; Anemia, hemolytic
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Summary The efficiency of cytolysis by the terminal complement proteins C5b-9 can be markedly enhanced by C3b molecules bound on the target cell membrane (Hammer et al. 1976). This enhancement was shown to be proportional to the number of C3b molecules on the cell membrane. The present experiments have shown that the hemolytic efficiency of the complement membrane attack system is two to five times greater on paroxysmal nocturnal hemoglobulinuria erythrocytes (PNHE) than on normal human E. This difference is attribut to a derivative of C3, probably C3b, on PNHE since it was abolished by anti-C3 but not by anti-C2. The efficiency of C5b-9 to lyse PNHE was only partially decreased by C3b inactivator and β 1H, indicating that the C3b on PNHE is not readily inactivated by its regulatory proteins. Furthermore, cells from a single severely affected patient consumed 3-fold more C5b6 than normal human E yet concommitantly measured membrane fluidity was normal. From these observations we conclude that cell-bound C3b on PNHE serves two functions: (a) it increases the hemolytic efficiency of membrane attack components of the complement system; and (b) it provides sites for assembly of the alternative pathway convertases.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Springer
    International journal of infrared and millimeter waves 5 (1984), S. 279-299 
    ISSN: 1572-9559
    Schlagwort(e): near millimeter waves ; optically pumped molecular laser ; Rexolite ; TPX ; Dynasil 4000
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Physik
    Notizen: Abstract A simple and versatile instrument for the measurement of optical constants in the near millimeter spectral region is described. Studies of quasi-optical components used in this instrument for effective beam transmission and control are reported. These studies include transmission characteristics of dielectric waveguides and performance of a variable coupler based on frustrated total internal reflection. Operation of this instrument as a two-beam interferometer for determining the index of refraction or as a device to measure transmission for determining the absorption coefficient are described. Values measured with this instrument at 245 GHz, using an optically pumped molecular laser as the source, are reported for several low-loss materials. Appropriate corrections and error estimates are discussed. The potential for improvement and increased accuracies are discussed.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...