Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1980-1984  (2)
  • Cardiac output  (1)
  • Dural carotid-cavernous fistula  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Neuroradiology 19 (1980), S. 249-256 
    ISSN: 1432-1920
    Keywords: Dural carotid-cavernous fistula ; Dural fistula ; Magnification angiography ; Expothalmus
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Eleven patients with dural carotid-cavernous sinus fistulae were studied with selective magnification angiography. The angiographic features of this condition were analyzed in detail. The arterial plexus normally present in and around the cavernous sinus has been thought to rupture into the sinus and establish an arteriovenous fistula with an extensive dural arterial supply. Changeable angiographic and clinical findings, including spontaneous regression, can be explained on the basis of thrombosis and occlusion in the arterial network. The indications for and methods of embolization are also discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 19 (1981), S. 638-644 
    ISSN: 1741-0444
    Keywords: Automatic determination ; Cardiac output ; Exercise ; Impedance plethysmograph
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract A computer-based system has been developed that enables the continuous measurement of cardiac output at rest as well as during exercise. The respiratory and motion artefacts appearing in the first derivative of the transthoracic impedance change (dZ/dt) were eliminated by adopting an ensemble averaging technique. A sufficiently high correlation was observed between cardiac outputs determined by the impedance and CO2 rebreathing methods. The system may facilitate the physiological investigation of cardiac function during exercise.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...