  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Neuroradiology 26 (1984), S. 253-259 
    ISSN: 1432-1920
    Keywords: DSA ; vessel resolution ; digital subtraction angiography ; intraarterial DSA ; IA DSA
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Comparative study was performed between IA DSA and stereoscopic magnification angiography in relation to small vessel resolution, image quality of the vessels and image quality of various pathologic lesions. The vessels of various diameters, accurately measured by stereoscopic magnification angiography, were localized on IA DSA and their resolution was carefully assessed. The vessels more than 1 mm in diameter were equally visualized on IA DSA and conventional angiography. The vessels between 1 mm and 0.5 mm showed fair resolution on IA DSA, whereas IA DSA did not resolve the vessels smaller than 0.5 mm in diameter to good advantage. In addition, image quality of the vessels on IA DSA was compared with the conventional methods. Cerebral gyrus, venous sinuses, and intracerebral veins are often shown better on DSA. The small vessels such as lenticulostriate, small cortical, thalamoperforate and meningohypophyseal arteries were not defined on DSA. Equal or better image quality was obtained in more than 85% of cases with pathologic lesions. Examinations were performed faster with lower cost and lower complication rate. Information provided by DSA was often sufficient for managements of patients. Combined use of DSA and conventional angiography will improve diagnostic accuracy and decrease the complication rate.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 19 (1981), S. 638-644 
    ISSN: 1741-0444
    Keywords: Automatic determination ; Cardiac output ; Exercise ; Impedance plethysmograph
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract A computer-based system has been developed that enables the continuous measurement of cardiac output at rest as well as during exercise. The respiratory and motion artefacts appearing in the first derivative of the transthoracic impedance change (dZ/dt) were eliminated by adopting an ensemble averaging technique. A sufficiently high correlation was observed between cardiac outputs determined by the impedance and CO2 rebreathing methods. The system may facilitate the physiological investigation of cardiac function during exercise.