Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1434-0879
    Keywords: Replacement of 2/3 of the ureter ; mobilisation of the bladder ; bladder-psoas-hitch, boari flap ; reimplantation of the ureter with submucosal tunnel ; preservation of the ureterovesical junction
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary The combination of two well established methods — the bladder-psoas-hitch procedure and the Boari flap — succeeded in replacing 2/3 of the lower ureter. After encouraging results on dogs, we performed this method successfully in one patient.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim [u.a.] : Wiley-Blackwell
    Materials and Corrosion/Werkstoffe und Korrosion 23 (1972), S. 364-370 
    ISSN: 0947-5117
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: Potential and polarization measurements on corrosion elementsThe polarization behaviour of heterogeneous mixed electrodes is of interest in connection with the assessment of the corrosion state of large objects involving macroelements and localized anodes, and in connection with the evaluation of the corrosion behaviour of weld seams. Measurements on a tube section have shown, that the influence of polarization and stray currents on local tube potentials and potential gradients in the electrolyte is increased by increased anodic polarization levels, provided, however, the current density: potential curves of the two partners diverge. Local anodes on welded connection can be found by measuring the surface potential; anodic polarization makes this method, too, more sensitive.
    Notes: Das Polarisationsverhalten heterogener Mischelektroden ist von Interesse in Verbindung mit der Beurteilung des Korrosionszustandes großer Objekte mit Makroelementen und örtlichen Anoden, sowie in Verbindung mit der Beurteilung des Korrosionsverhaltens von Schweißnähten. Messungen an einem Rohrabschnitt haben gezeigt, daß der Einfluß der Polarisation und der Streuströme auf die örtlichen Rohrpotentiale und die Potentialgradienten im Elektrolyten durch die Höhe der anodischen Polarisation verstärkt wird, vorausge-setzt, die Stromdichte: Potential-Kurven der beiden Partner sind divergent. Örtliche Anoden an Schweißverbindungen können durch Messen des Oberflächen-potentials ermittelt werden; auch diese Methode wird duch anodisches Polarisieren empfindlicher.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim [u.a.] : Wiley-Blackwell
    Materials and Corrosion/Werkstoffe und Korrosion 22 (1971), S. 1012-1019 
    ISSN: 0947-5117
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: Experience concerning the cathodic protection of underground steel storage containersReport concerning investigations into the behaviour of underground storage containers protected by Zn anodes (model experiments with empty containers) or by impressed current systems. The use of Zn anodes turns out to be insufficient, even in soils having resistivities exceeding 10 000 ohms; the use of Mg anodes would be more favourable. In the case of impressed current protection systems actual containers were used : propane gas container (117 500 litres), gasoline container (3 000 litres), fuel oil containers (40 000, 30 000 and 7 000 litres). These experiments have yielded the following experiences: current feeding tests made to assess the current requirement have practically no value. The current densities measured (which are comparable to the protective current densities) are high with reference to those measured on pipelines. Measurement of the switch-in po-tential has no value, while the shut-off potential measured immediately after interrupting the protective current is very important. Stationary polarization conditions are obtained after some months only; this is why current feed tests yield no information in this respect either. Frequent inspection of the installations is indispensable, even when a resistance measurement does not indicute the necessity of an electrical separation of the attached tubing.
    Notes: Bericht über Untersuchungen an erdverlegten Lagerbehältern, die durch Zn-Anoden (Modellversuche mit leeren Be-hältern) oder durch Fremdstrom kathodisch geschützt waren. Die Verwendung der Zn-Anoden erweist sich als ungünstig, auch bei Erdböden mit spezifischem Widerstand oberhalb 10000 Ohm; besser wäre die Verwendung von Mg-Anoden. Im Falle der Versuche rnit Schutz durch Fremdstrom wurden in Betrieb befindliche Behälter verwendet: Propangasbehälter (117 500 l), Benzinbehälter (3 000 l), Heiz-ölbehälter (40 000 l, 30 000 1, 70001). Da-bei werden die folgenden Erfahrungen gewonnen: Einspeiseversuche zur Abschätzung des Strombedarfs sind praktisch ohne Aussagekraft. Die gemessenen Stromdichten (die mit den Schutzstromdichten vergleichbar sind) liegen im Vergleich zu Rohrleitungen hoch. Die Messung des Einschaltpotentials hat keine Aussagekraft, wichtig ist hingegen das Ausschaltpotential, gemessen unmittelbar nach Ausschalten des Schutzstromes. Stationäre Polarisationsverhältnisse stellen sich erst nach mehreren Monaten ein: deshalb erlauben Einspeisungsversuche auch hierüber keine Aussage. Eine häufige Überprüfung der Anlagen ist notwendig, auch wenn eine Widerstandsmessung eine elektrische Trennung der angeschlossenen Rohre als nicht notwendig erscheinen läßt.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...