Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • $$P_{{\text{O}}_{\text{2}} }$$ Electrode  (1)
  • Arteriovenous anastomoses  (1)
  • Best. von Ethanol in Körperflüssigkeiten  (1)
  • Bloodless Determination of the Arterial $$P_{O_2 }$$ and $$P_{CO_2 }$$ , Bloodless Determination of the Acid/Base Status  (1)
  • Carotid body  (1)
Materialart
Erscheinungszeitraum
Schlagwörter
  • 1
    ISSN: 1432-1440
    Schlagwort(e): Transcutaneous $$P_{O_2 }$$ ; Transcutaneous $$P_{CO_2 }$$ ; in vivo determination of the local capillary Hb concentration ; Bloodless Determination of the Arterial $$P_{O_2 }$$ and $$P_{CO_2 }$$ , Bloodless Determination of the Acid/Base Status ; Transcutane $$P_{O_2 }$$ ; transcutaner $$P_{CO_2 }$$ ; in vivo-Bestimmung der lokalen capillären Hämoglobinkonzentration ; unblutige Erfassung der Blutgase ; unblutige Erfassung des Säure-Basen-Status
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Beschreibung / Inhaltsverzeichnis: Zusammenfassung Arterielle Blutgaswerte lassen sich transcutan erfassen, wenn die Perfusionseffizienz der Haut so hoch ist, da\ kleine Änderungen der Durchblutung den gemessenen $$P_{O_2 }$$ - und $$P_{CO_2 }$$ -Wert nicht verändern. Dies läßt sich mit speziell konstruierten, thermostatisierten und geheizten $$P_{O_2 }$$ - und $$P_{CO_2 }$$ -Elektroden erreichen. Die zur Temperatur-regelung notwendige Heizleistung ist ein Maß für die Perfusion, die gleichzeitige Veränderung des $$P_{O_2 }$$ oder $$P_{CO_2 }$$ ein Maß für die Effizienz. Ist der arterielle $$P_{O_2 }$$ und $$P_{CO_2 }$$ bekannt, so läßt sich der Säure-Basen-Status nach der bekannten Methode der Blutnomographie bestimmen.
    Notizen: Summary Arterial blood gas values can be monitored transcutaneously, if the perfusion efficiency of the skin is so high that small changes in blood flow do not change the measured $$P_{O_2 }$$ and $$P_{CO_2 }$$ values. This is brought about by specially constructed $$P_{O_2 }$$ and $$P_{CO_2 }$$ electrodes which are heated and thermostated. The power necessary to regulate the temperatures of the electrode serves as an index of the perfusion, the simultaneous change of the transcutaneous $$P_{O_2 }$$ and $$P_{CO_2 }$$ as an index of efficiency. Knowing the arterial $$P_{O_2 }$$ and $$P_{CO_2 }$$ , the acid/base status can be determined by applying the well known methods of blood nomography.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 1432-2013
    Schlagwort(e): Mitochondrial Respiration Rate ; $$P_{{\text{O}}_{\text{2}} }$$ Electrode ; Critical Oxygen Tension
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Summary The respiration of cells and mitochondria of different rat tissues and of ascites tumor cells was measured with a polarographic method. The rate of respiration (μl O2/mg mitochondria protein×min) was controlled by the substrate, by the addition of ADP and by the temperature (25° and 37°C). By means of a membrane-covered platinum electrode no correlation was found between the rate of respiration and the $$P_{{\text{O}}_{\text{2}} }$$ below of which the rate of oxygen consumption decreases. Under optimum conditions especially at saturating concentrations of ADP and substrate, the rate of respiration (measured between ∼120 and 0 Torr $$P_{{\text{O}}_{\text{2}} }$$ ) is not sufficiently constant to allow the definition of a “critical $$P_{{\text{O}}_{\text{2}} }$$ ” as the $$P_{{\text{O}}_{\text{2}} }$$ measured polarographically, at which the rate of respiration drops to 90% of the maximum rate. Due to the variations in the $$P_{{\text{O}}_{\text{2}} }$$ measurements the above “critical $$P_{{\text{O}}_{\text{2}} }$$ ” becomes strongly dependent on the method of computation used to fit the $$P_{{\text{O}}_{\text{2}} }$$ values measured to a straight line and to measure the rate of respiration from it. An additional difficulty is induced by the response time of the electrode which causes the $$P_{{\text{O}}_{\text{2}} }$$ measured to follow the real $$P_{{\text{O}}_{\text{2}} }$$ with a time lag large enough to significantly influence the measurements of the “critical $$P_{{\text{O}}_{\text{2}} }$$ ”. Because of these difficulties, the so measured “critical $$P_{{\text{O}}_{\text{2}} }$$ ” is not a function of the respiratory properties of cells and mitochondria but depends largely on the measuring device.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    Springer
    Cell & tissue research 142 (1973), S. 515-524 
    ISSN: 1432-0878
    Schlagwort(e): Arteriovenous anastomoses ; Carotid body ; Cat ; Corrosion casting technique ; Scanning electron microscopy
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Biologie , Medizin
    Beschreibung / Inhaltsverzeichnis: Zusammenfassung In den arteriennahen, peripheren Bereichen des Glomus caroticum der Katze wurden arteriovenöse Verbindungen nachgewiesen, die ihrem Charakter nach unterschiedlich sind. Es ist allerdings noch nicht zu entscheiden, ob derartige Anastomosen regelmäßig vorkommen und wie sie funktionieren. Die beschriebenen Gefäßverbindungen konnten lichtmikroskopisch anhand von histologischen Serienschnitten und mit Hilfe einer weiterentwickelten Korrosionstechnik im Rasterelektronenmikroskop dargestellt werden.
    Notizen: Summary In artery surrounding areas in the periphery of the carotid body of the cat we found arteriovenous anastomoses differing in respect to their character. So far, it is not yet to decide the frequency of their occurrence and their functional significance. The anastomoses were demonstrated by light microscopy of serial sections and by scanning electron microscopy with a more developed corrosion casting technique.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Digitale Medien
    Digitale Medien
    Springer
    Fresenius' Zeitschrift für analytische Chemie 301 (1980), S. 162-163 
    ISSN: 1618-2650
    Schlagwort(e): Best. von Ethanol in Körperflüssigkeiten ; Enzymatische Analyse ; Fluorescenzmessung
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...