Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • ventricular interaction  (2)
  • 07.35.+k  (1)
  • 33  (1)
  • Aesthetic refinement  (1)
Material
Years
Keywords
  • 1
    ISSN: 1432-0649
    Keywords: 33
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Energy efficiency has been discussed in the multi-stage laser separation of13C in the ir laser photolysis of CF3I. The comparison has been made between the two methods, i.e., the photolysis of13C molecules (ordinary method) and the photolysis of12C molecules (elimination method). The former recycles the photolyzed product after the regeneration of feed molecules, while the latter recycles the residue after the elimination of the photolyzed product. The analysis of the energy consumption using theoretical models has shown that the elimination method consumes more energy, but the difference is far less than expected; the overall energy consumption may reach the same level at a lower pressure according to our estimation which includes the factors of the quantum efficiency for the dissociation, the energy difference between the laser lines and the material loss for the regeneration. It may imply that the elimination method is more favored in a practical application because it is free from the regeneration procedure.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-0649
    Keywords: 42.55.Mv ; 06.60.Jn ; 07.35.+k
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract It is demonstrated that broadly tunable picosecond pulses are generated from a dye laser of very short cavity utilizing a diamond-anvil cell, which operates at pressures up to 10 GPa. The pulses as short as 5 ps are obtained from the rhodamine 6G dye laser pumped by a frequency-doubled Q-switched Nd: YAG laser. The way of tuning is based on the pressure induced shift of the emission peak of the dye. The laser is tunable over 20 nm by changing the pressure of the cell within 4 GPa.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Basic research in cardiology 78 (1983), S. 544-559 
    ISSN: 1435-1803
    Keywords: ventricular interaction ; diastolic compliance ; RV overload ; contractility
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary We investigated ventricular interaction by the use of six excised, perfused, canine hearts. In this preparation, we could change the filling pressure of the right and left ventricles independently, thereby breaking the normal series-pump arrangement. We found that mechanical ventricular interaction exists in diastole and in systole. Namely, not only decreased diastolic ventricular compliance, but also the reduced performance in either ventricle was found, when the opposite ventricular pressure was increased. Thus, when the opposite ventricular filling pressure increases, we suspect that systolic ventricular function of either ventricle will be depressed significantly by these two factors; i.e., the Frank-Starling effect due to decreased ventricular diastolic volume following decreased diastolic ventricular compliance, and the depressed systolic ventricular function. Clinically, these findings may be important in considering the mechanism of the occurrence of simultaneous reduced performance of both ventricles in cases when only one side of the ventricle is affected hemodynamically and its filling pressure is greatly increased in various pathological states such as heart failure.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1435-1803
    Keywords: end-systolicpressure-volume relationship ; ventricular interaction ; systemicvascular resistance ; rightventricular volume ; rightventricular shortening
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary It has been reported that left ventricular end-systolic volume decreases during arteriovenous shunt and increases during subclavian artery-left atrium shunt at a constant end-systolic pressure. The mechanism of the opposing changes in end-systolic volume during the two types of shunt is not clear. One possible cause is that left ventricular pump function with enhanced right ventricular ejection differs from that without enhancement. To investigate this hypothesis, we studied the two types of shunt (Aorto-femoral vein shunt, AoFV; aorto-left atrium shunt, AoLA) with matched reduction of systemic vascular resistance in open-chest dogs with β-blockade. Both right and left ventricular volumes and shortenings were assessed from short-axis views by two-dimensional (2D)-echocardiogram. Left ventricular end-systolic short-axis area decreased from 76 ± 3 to 62 ± 3% in AoFV shunt (p 〈 0.05), but tended to increase in AoLA shunt (76 ± 4 in control state vs 81 ± 5% in AoLA, NS) in spite of a similar reduction in left ventricular end-systolic pressure. There was no difference in left ventricular shortening, but significant differences were observed in right ventricular shortening (50 ± 8 in AoFV vs 24 ± 7% in AoLA, p 〈 0.05) and right ventricular short-axis area at end-diastole (142 ± 6 in AoFV vs 96 ± 3% in AoLA, p 〈 0.01), and at end-systole (92 ± 8 in AoFV vs 73 ± 7% in AoLA, p 〈 0.05) between the two types of shunt. We conclude that the different changes in left ventricular end-systolic short-axis area found in the two shunts are not caused by the different left ventricular shortenings, but by the different right ventricular mechanical actions. These findings suggest that left ventricular pumping action in the high output state changes, depending on whether it is accompanied by augmented ejection of the right ventricle or not.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    European journal of plastic surgery 14 (1991), S. 280-284 
    ISSN: 1435-0130
    Keywords: Reduced latissimus dorsi musculocutaneous flap ; Tissue expander ; Aesthetic refinement ; Capsular vascular plexus
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary The reduced latissimus dorsi musculocutaneous flap is a recently reported flap, consisting of a proximal musculocutaneous unit and a distal, thin fasciocutaneous or cutaneous unit. It can be used to obtain satisfactory contour of the recipient site. In cases where a larger and thinner flap is required, we employ pretransfer tissue expansion of the reduced latissimus dorsi flap. Application of the tissue expander appears to increase both the area and the vascularity of the flap. We have so far employed two pedicled and four free-expanded reduced latissimus dorsi flaps in the repair of a variety of defects. All of these flaps survived, and suitable contour, along with primary closure of the donor site, was obtained.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...