Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1619-7089
    Keywords: 11C-DOPA ; 11C-tyrosine ; Melanoma ; Positron emission tomography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract In order to investigate the possibility of using [1-11C] labelled 3,4-dihydroxyphenylalanine (DOPA) and tyrosine as radiopharmaceuticals for the detection of eye melanoma, the biodistributions of the same 1- and 3-14C-labelled compounds were investigated in Syrian golden hamsters with Greene melanoma. The results of these investigations were compared with positron emission tomography (PET) images of 11C labelled DOPA and tyrosine. The synthesis of these 11C labelled compounds procures of DL mixture, from which D and L forms can be separated. One h after intravenous injection, both 14C labelled DL-, L-and D-DOPA showed a high uptake in tumour tissue, that of DL- and D-DOPA being the highest. These high uptakes, together with relatively low uptake in bone, skin and eye resulted in high tumour/non tumour ratio (for DL-DOPA 5.9, 4.5 and 6.6 respectively). Extraction of the tumour tissue with trichloroacetic acid showed that L-DOPA was mainly incorporated into melanin, whereas D-DOPA was not. Also, the uptake 1 h after intravenous injection of 1-14C-L- and DL-tyrosine into the tumour were high, but L- and DL- were less different; tumour/non tumour ratios were favorable. PET images of the tumour obtained 40–80 min after injection of the [1-11C] labelled DOPA and tyrosine confirmed that melanoma detection was promising and that D-DOPA produced a better melanoma image than L-DOPA.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1619-7089
    Keywords: ECG gated scintigraphy ; 201Tl space and time filter
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Stress 201Tl myocardial images were obtained using a standard ECG gated acquisition protocol for 10 min per view. These images were filtered using a three dimensional space and time filter. The effects of filtering were evaluated by sectorial analysis. Comparing raw and filtered dynamic images, quantification demonstrated that filtering did not produce artefacts. A conventional static image was also obtained as the sum of the series of unfiltered dynamic images. Comparison of raw static and filtered diastolic images indicated that the latter demonstrated myocardial abnormalities more clearly (P〈0.01) in 33 patients. Improvement in the signal to noise ratio produced by filtering made cinematic display and visual analysis possible which was not feasible with raw gated images. Clinical evaluation is in progress.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...