Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-0649
    Keywords: 42.55.Vc ; 32.30.Rj ; 52.70
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract We point out that existing Ne-like X-ray lasers have sufficient brightness to be used as pump sources in resonant pump-fluorescence experiments, and we discuss some of the potential benefits and limitations of such experiments. In preliminary experiments, we have measured the line overlap of the Ne-like yttrium X-ray laser near 155 Å with 4f−3d transitions in H-like Na and He-like Mg. These experiments used a high-resolution grating spectrometer, and calibrated the wavelength of the yttrium laser by comparison against lines of known wavelength. The results indicate that the wavelength of the yttrium laser is 154.985 ± 0.025 Å, a factor of 2–4 improvement in precision over previous calibrations. We find that the yttrium laser is ≈ 100 mÅ to the long-wavelength side of both the He-like Mg line and the H-like Na line, so that neither resonance is perfect; however, Stark broadening could improve the overlap in the latter scheme, and bulk Doppler shifting could improve both resonances. We also find a good resonance between the yttrium laser and an un-identified transition which we tentatively attribute to copper.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-2102
    Keywords: Schlüsselwörter ; Herz ; Herz-MR ; Volumen ; Cine MR ; Key words ; Heart ; Cardiac MRI ; Volume ; Cine MR
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary Purpose: To evaluate method- and user effects as well as the required time in the determination of left- and right ventricular ejection fractions in comparing manual and semiautomatic border detection of the endocardium. Methods: In 22 patients with varying cardiac diseases endocardial borders were detected either manually or semiautomatically (seeded ROI) and subsequently the right and left ventricular volume ejection fractions were computer-calculated. Two investigators defined the endocardial borders for both ventricles using both methods. For statistical analysis two-factorial analyses of variance were performed for the four variables: VEF right ventricle, VEF left ventricle, required time right ventricle, required time left ventricle (SAS, Anova). Results: There was no user or method effect detectable for both ventricles. The required time for both ventricles also did not reveal a user effect, but there was a dramatic method effect concerning a reduction of the required time for analysis for both ventricles 〉50%. Conclusions: The semiautomatic mode for detecting the endocardial borders in determining right and left ventricular ejection fractions did not demonstrate results differing from the results of the manual method, but is significantly superior concerning the time required for analysing ejection fractions of both ventricles with a reduction of over 50%. This might significantly reduce the expenditure for personnel.
    Notes: Zusammenfassung Fragestellung: Die manuelle und semiautomatische Endokarddetektion zur Bestimmung links- und rechtsventrikulärer Volumenejektionsfraktionen (VEF) werden verglichen. Ziel dieser Arbeit ist die Evaluierung des Methoden- und Anwendereffekts sowie der Bearbeitungszeit beider Verfahren. Methode: An 22 Patienten mit unterschiedlichen kardialen Erkrankungen wurden die Endokardgrenzen manuell und mit einem semiautomatischen Verfahren (Seeded-ROI) ermittelt und anschließend die rechts- und linksventrikulären Volumenejektionsfraktionen automatisch berechnet. In allen Fällen wurden von 2 Untersuchern die Endokardgrenzen des rechten und linken Ventrikels manuell und semiautomatisch bestimmt. Zur statistischen Analyse wurden 2-faktorielle Varianzanalysen (Methoden- und Anwendereffekt einschließlich Wechselwirkungen) für die 4 Variablen durchgeführt: VEF rechtsventrikulär, VEF linksventrikulär, Zeitaufwand rechtsventrikulär, Zeitaufwand linksventrikulär (SAS, Anova). Ergebnisse: Bezüglich der Bestimmungen der rechts- und linksventrikulären VEF war weder ein Methoden- (p=0,9613) noch ein Anwendereffekt (p=0,3095) nachweisbar. Bezogen auf die benötigte Bearbeitungszeit fand sich ebenfalls kein Anwendereffekt, aber ein massiver Methodeneffekt (p〈0,0001) im Sinn einer Reduzierung der Bearbeitungszeit um 〉50% sowohl für den rechten als auch für den linken Ventrikel. Schlussfolgerung: Nach unseren Erfahrungen liefert das semiautomatische Seeding-Verfahren zur Festlegung der Endokardgrenzen bei der Bestimmung der links- und rechtsventrikulären Ejektionsfraktionen keine von der manuellen Methode abweichenden Ergebnisse, ist aber bezüglich der Bearbeitungszeit deutlich überlegen. Die über 50%ige Zeitersparnis reduziert den Personalaufwand.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...