Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 74.72. Bk  (1)
  • 75.30.Et  (1)
  • Key words: Distributed computing – Internet technology – Nuclear medicine  (1)
  • Proximal ACL reinsertion  (1)
  • absolute cross sections  (1)
  • barrier/asperity models  (1)
  • damaged area  (1)
Material
Keywords
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Knee surgery, sports traumatology, arthroscopy 1 (1993), S. 17-19 
    ISSN: 1433-7347
    Keywords: Proximal ACL reinsertion ; Late results
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Sports Science
    Description / Table of Contents: Zusammenfassung Zwischen 1982 and 1984 wurden im Unfallkrankenhaus Salzburg 49 Patienten mit frischen isolierten proximalen Rupturen des vorderen Kreuzbandes operiert. Die Operation erfolgte bei allen Patienten innerhalb der 1. Woche nach dem Trauma. Die von uns durchgeführte Operationstechnik war die alleinige proximale Reinsertion des gerissenen vorderen Kreuzbandes über 2 Bohrkanäle transossär bzw. über einen transossären Bohrkanal und “over the top”. Die postoperative Ruhigstellung erfolgte im Oberschenkelgehgipsverband für insgesamt 6 Wochen. 42 unserer 49 operierten Patienten konnten wir zwischen 5 und 7 Jahre postoperativ nachuntersuchen. Dabei wurde neben der klinischen Stabilitätsprüfung auch eine Stabilitätsprüfung mit dem KT 1000 durchgeführt. Die objektiven und subjektiven Ergebnisse wurden nach dem Lysholm Scale und nach dem OAK-Bogen ausgewertet. Dabei fanden wir in 29% absolut stabile Kniegelenke. Gibt man sich mit einem KT 1000 Meßwert bis zu 3 mm zufrieden, so fielen 81% unserer Patienten in diese Kategorie. Der Lysholm Score lag ebenfalls bei 81% und über 85 Punkten. Im OAK-Bogen wiesen lediglich 52% über 90 Punkte auf. Subjektiv waren nur 14% unserer Patienten mit dem Ergebnis unzufrieden.
    Notes: Abstract Between 1982 and 1984, 49 patients with fresh isolated proximal ruptures of the anterior cruciate ligament (ACL) were operated on in the Trauma Hospital, Salzburg. The operation was performed within 1 week of trauma. The operational technique used was proximal reinsertion of the ruptured ACL alone. Postoperatively the knee was immobilized for 6 weeks in an above-theknee plaster cast. We were able to re-examine 42 of the 49 patients 5–7 years after injury. In addition to a clinical examination, testing with a KT-1000 arthrometer was performed. The objective and subjective results we found were evaluated using the Lsyholm score and OAK knee evaluation form. We found 12 (29%) absolutely stable knee joints. We accepted a KT-1000 result of up to 3 mm as satisfactory, and 81% of our patients were in this category. The same percentage (81%) scored between 85 and 100 points on the Lysholm scale. Only 52% scored over 90 points on the OAK form. Subjectively only 6 patients (14%) were dissatisfied with their result.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Pure and applied geophysics 129 (1989), S. 513-521 
    ISSN: 1420-9136
    Keywords: Mine-induced seismicity ; source models ; barrier/asperity models ; seismic moment ; rockbursts ; damaged area
    Source: Springer Online Journal Archives 1860-2000
    Topics: Geosciences , Physics
    Notes: Abstract One possibility to estimate and to interpret the source parameters of low-stress drop seismic events to use the barrier or the asperity model. These models serve as the description of seismic events in a in which a horizontal room and pillar mining method is used in great depth. An additional macroseismic parameter, the destroyed or damaged area in the mine, allows the estimation of the real static stress drop of mining-induced seismic events. This stress drop, derived from a simplified barrier-or asperity-model, appears to be a constant and a characteristic parameter for a given source region. On this base, a relation between the underground destruction or damages and the seismologically estimated parameters is derived and is used for the classification of the mining-induced seismic events.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    European radiology 10 (2000), S. 1483-1486 
    ISSN: 1432-1084
    Keywords: Key words: Distributed computing – Internet technology – Nuclear medicine
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract. At present, medical applications applying World Wide Web (WWW) technology are mainly used to view static images and to retrieve some information. The Java platform is a relative new way of computing, especially designed for network computing and distributed applications which enables interactive connection between user and information via the WWW. The Java 2 Software Development Kit (SDK) including Java2D API, Java Remote Method Invocation (RMI) technology, Object Serialization and the Java Advanced Imaging (JAI) extension was used to achieve a robust, platform independent and network centric solution. Medical image processing software based on this technology is presented and adequate performance capability of Java is demonstrated by an iterative reconstruction algorithm for single photon emission computerized tomography (SPECT).
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Journal of low temperature physics 105 (1996), S. 383-388 
    ISSN: 1573-7357
    Keywords: 78.3O.Hv ; 74.72. Bk ; 71.10.Fd ; 75.30.Et
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Absolute Raman efficiencies of phononic, electronic and spin excitations have been determined for doped and undoped HTc-cuprates. Anomalous temperature dependence of the Raman efficiency of the phononic 500cm−1 mode is explained as a change of the apical oxygen position. The normal state efficiency of the. ‘electronic’ background in YBa2Cu3O6.9 has been obtained for various scattering geometries for Raman shifts up to 8000cm−1. The 2-magnon contribution to the magnetic Raman signal of the undoped and lightly doped cuprates has been measured quantitatively and compared with recent calculations based on the 3-band-Hubbard model. Possible contributions of magnetic Raman scattering to the electronic B1g background of the superconducting samples are discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Journal of superconductivity 9 (1996), S. 463-465 
    ISSN: 1572-9605
    Keywords: Raman ; Y1−x Pr x Ba2Cu3O y ; two-magnon scattering ; phonons ; absolute cross sections
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Notes: Abstract The Y1−x Pr x Ba2Cu3O6.9 system has been investigated by quantitativeμ-Raman measurements. The magnetic response of the antiferromagnetic ordered Cu spins in the CuO2 plane has been observed via the two-magnon-Raman scattering. The in-plane exchange energy is determined to 780 cm−1 in the system withx=1. Phonon behavior as well as magnetic scattering indicate that the band structure of the CuO2 planes in PrBa2Cu3O6.9 is similar to that in insulating YBa2Cu3O6.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...