Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 79.40  (1)
  • Key words:Micro-CT – Osteoporosis – Plain radiograph – Three-dimensional – Trabecular bone – Trabecular architecture  (1)
  • demineralization  (1)
Material
Years
Keywords
  • 1
    ISSN: 1433-2965
    Keywords: Key words:Micro-CT – Osteoporosis – Plain radiograph – Three-dimensional – Trabecular bone – Trabecular architecture
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract: The purpose of this study was to determine the relationship between three-dimensional (3D) trabecular structure and two-dimensional plain radiographic patterns. An in vitro cylinder of human calcaneal trabecular bone was three-dimensionally imaged by micro-CT using synchrotron radiation, at 33.4 μm resolution. The original 3D image was processed using 14 distinct sequences of morphologic operations, i.e., of dilations and erosions, to obtain a total of 15 3D models or images of calcaneal trabecular bone. These 15 models had distinct densities (volume fractions) and architectures. The 3D structure of each calcaneal model was assessed using mean intercept length (fabric), by averaging individual fabric measurements associated with each medial-lateral image slice, and determining the relative anisotropy, R3D, of the structure. A summated pattern or plain radiograph was also computed from the 3D image data for each calcaneal model. Each summated pattern was then locally thresholded, and the resulting two-dimensional (2D) binary image analyzed using the same fabric analysis as used for the 3D data. The anisotropy of the 2D summated pattern was denoted by Rx-ray. The volume fractions of the 15 models ranged from 0.08 to 0.19 with a mean of 0.14. The medial-lateral anisotropies, R3D, ranged from 1.38 to 2.54 with a mean of 1.88. The anisotropy of the 2D summated patterns, Rx-ray, ranged from 1.35 to 2.18 with a mean of 1.71. The linear correlation of the 3D trabecular architecture, R3D, with the radiographic trabecular architecture, Rx-ray, was 0.99 (p〈0.0001). This study shows that the plain radiograph contains architectural information directly related to the underlying 3D structure. A well-controlled sequential reproducible plain radiograph may prove useful for monitoring changes in trabecular architecture in vivo and in identifying those individuals at increased risk of osteoporotic fracture.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-0630
    Keywords: 79.40 ; 79.60
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Abstract Electron emission due to 1.06 and 0.35 μm laser excitation has been measured at several pulse lengths for a number of wide bandgap semiconductors and insulators. The dependence on fluence and wavelength is consistent with multiphoton excitation across the bandgap. The work functions of the materials investigated do not appear to influence the rate-limiting multiphoton excitation process.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 0021-9304
    Keywords: dentin ; demineralization ; shrinkage ; rehydration ; atomic force microscopy ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Most current dentin bonding procedures use acid etchants to partially demineralize the dentin structure and provide pathways for resin infiltration. This study determined the recession rates of peritubular dentin and intertubular dentin as a function of pH during demineralization in citric acid solutions (0.0005-2.5M) and the effects of dehydration and rehydration on the partially demineralized dentin. Polished dentin disks were prepared with an internal reference layer and were studied at specific intervals for citric acid etching between pH 1 and 3.4 in an atomic force microscope. Peritubular dentin etched rapidly and linearly with time until it could no longer be measured. The intertubular surface began etching at nearly the same rate, but then recession slowed for all concentrations and stabilized after recession of less than 1 μm for all but the pH 1 solution. The decrease in recession was attributed to the limitation of contraction of the demineralized collagen scaffold as long as it remained hydrated. Dehydration following etching resulted in significant collapse of the surface, changes in roughness, and a slight decrease in tubule diameter for samples etched for 30 min. Measurements could not be made of the collapse for low pH samples, because shrinkage stresses disrupted the integrity of the reference layer. On rehydration, the dehydrated surfaces underwent an expansion up to the level seen after etching and tubule diameters returned to the etched values. These results indicate that the collapse of demineralized matrix is almost totally recoverable on rehydration. © 1998 John Wiley & Sons, Inc. J Biomed Mater Res, 42, 500-507, 1998.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability