    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 17 (1983), S. 125-131 
    ISSN: 1612-1112
    Keywords: Miniaturized HPLC ; Post-column reaction detection ; Catecholamines ; Packed-bed reactors ; Non-segmented open-tubular reactors
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The use of non-segmented flow, post-column reaction detection is evaluated for use with miniaturized HPLC. Non-segmented open-tubular reactors with internal diameters 0.1 mm to 0.25 mm and packed-bed reactors with internal diameters of 1 mm, filled with 5 and 10 μm particles are evaluated theoretically and experimentally with respect to band broadening and pressure drop characteristics. An integrated system consisting of miniaturized HPLC (1 mm i. d.) columns and compatible hardware is described. An example of the separation of catecholamines is given.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1612-1112
    Keywords: Liquid chromatography ; Photochemical reaction detection ; Chemical post-column reduction ; Fluorimetric detection ; Air segmented flow systems ; Non-aqueous reversed-phase chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A new photochemical reaction method for the on-line fluorimetric detection of natural vitamin K homologs was developed. In addition to its high sensitivity, the method features an interesting selectivity for the determination of these compounds in a complex matrix such as human serum. The formation of different photolysis products as a function of reaction conditions, and the optimalisation of a segmented flow reaction system will be discussed. The results indicate that the method is 4 times more sensitive than UV detection, and at least as selective as fluorescence detection after post-column chemical reduction.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1612-1112
    Keywords: Chemical excitation source ; Chemiluminescence detector ; Chemical band narrowing ; Dansyl derivative ; Serum
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A peroxyoxalate chemiluminescence detection system for liquid chromatography is described. The excitation of fluorophores is generated by the reaction of bis-(2,4,6-trichlorophenyl)oxalate or bis(2,4-dinitrophenyl)oxalate and hydrogen peroxide, which are added to the column effluent. The influence of the solvents and the concentrations of the reagents have been investigated. The influence of the flow cell volume on sensitivity and on band broadening have also been studied and a “chemical band narrowing effect” has been observed. Different types of apparatus have been compared for detection of the emitted light. The system has been used for the detection of the dansyl derivative of a drug with a secondary amine functional group in serum samples. The detection limits are in the 1–10pg range.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability