Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1612-1112
    Keywords: Liquid chromatography ; Photochemical reaction detection ; Chemical post-column reduction ; Fluorimetric detection ; Air segmented flow systems ; Non-aqueous reversed-phase chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A new photochemical reaction method for the on-line fluorimetric detection of natural vitamin K homologs was developed. In addition to its high sensitivity, the method features an interesting selectivity for the determination of these compounds in a complex matrix such as human serum. The formation of different photolysis products as a function of reaction conditions, and the optimalisation of a segmented flow reaction system will be discussed. The results indicate that the method is 4 times more sensitive than UV detection, and at least as selective as fluorescence detection after post-column chemical reduction.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0887-6134
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A multi-stage screening and identification scheme for the diagnosis of inborn errors in amino acid, fatty acid, carbohydrate and intermediary metabolism is described. The method is based on a computerized analysis of data obtained with dual-column gas chromatography/FID (GC/FID) and gas chromatography/mass spectrometry (GC/MS) profiling of urinary organic acids. It involves: (1) isolation of the compounds by solvent or solid-phase extraction; (2) conversion into trimethylsilyl (TMS) or TMS-oxime derivatives; (3) GC/FID analysis on SE-52 and OV-1701 capillary columns; (4) tentative identification by comparing the methylene unit (MU) values on both columns with a user-built library of reference compounds; (5) quantitative evaluation of the excretion profile; and (6) analysis by GC/MS of samples with an abnormal profile using an automated peak identification programme.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...