Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Chemistry  (29)
  • Alternating ventilation  (2)
  • Bolus injections  (2)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Intensive care medicine 22 (1996), S. 813-817 
    ISSN: 1432-1238
    Keywords: Alternating ventilation ; Cardiac output ; Central venous pressure ; Intrathoracic pressure ; Lung volume ; Pericardial pressure
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Objective We tested the hypothesis that mean thoracic expansion (and mean lung volume) is lower during alternating ventilation (AV), i.e. ventilation of both lungs with a phase shift of half a ventilatory cycle, compared to synchronous ventilation (SV) of both lungs. As a consequence, intrathoracic pressure will be lower, causing lower, central venous pressure and higher cardiac output. Design In eight anaesthetized and paralysed piglets, differential ventilation was established by fixation of an endobronchial tube in the left main bronchus. SV and AV were sequentially applied for four and three periods, respectively, of 10 minutes each. Minute ventilation was the same during AV and SV and adapted to normocapnia. Two series of observations were performed: series 1 with intact thorax and monitoring of oesophageal pressure; series 2 after perforation of the sternum, airtight closure of the thorax and monitoring of pericardial pressure. Results In both series, mean lung volume was 16±4% lower and central venous, oesophageal (series 1) and pericardial pressures (series 2) were 0.5±0.7 mmHg lower during AV compared to SV (allp〈0.001). In series 1, aortic pressure was 5 mmHg and cardiac output 8% higher (bothp〈0.001). In series 2, cardiac output was 5% higher during AV (p〈0.001), but aortic pressure did not change (p=0.07). Conclusion Our data verified the hypothesis. The lower oesophageal (series 1), pericardial (series 2) and central venous pressures during AV compared to SV could be explained by the smaller thoracic expansion due to the lower mean lung volume, which was attributed to compression of the opposite lung by the expansion of the inflated lung.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1238
    Keywords: Key words Oleic acid ; Lung injury ; Respiratory distress ; Albumine ; Bolus injections
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract   Objective: Development of a stable model of respiratory distress in pigs with oleic acid, fulfilling clinical criteria of the adult respiratory distress syndrome (ARDS). Design: Eight pigs (9.1±0.7 kg) were anesthetized with pentobarbital, paralyzed with tubocurarine and mechanically ventilated with an FIO2 of 0.6, an I:E ratio of 2:3 and a PEEP of 0.2 kPa. Oleic acid (dissolved 1:1 in 96% alcohol) was administered in a series of multiple injections of 0.1 ml until P aO2 was lower than 8 kPa. Measurements and results: Careful titration of the oleic acid injections on guidance of the P aO2 established a reproducible respiratory distress (P aO2=7.3±0.8 kPa), in which gas exchange and hemodynamic variables were stable for at least 4 h. The number of oleic acid injections (22±11, mean and SD) varied between the animals. Conclusions: With the use of multiple injections of oleic acid, a stable model of early respiratory distress in pigs can be achieved, in spite of individual differences in sensitivity. Such a stable model allows for a diversity of studies on early respiratory distress.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-1238
    Keywords: Oleic acid ; Lung injury ; Respiratory distress ; Albumine ; Bolus injections
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Objective Development of a stable model of respiratory distress in pigs with oleic acid, fulfilling clinical criteria of the adult respiratory distress syndrome (ARDS). Design Eight pigs (9.1±0.7 kg) were anesthetized with pentobarbital, paralyzed with tubocurarine and mechanically ventilated with an $$F_{IO_2 } $$ of 0.6, an I∶E ratio of 2∶3 and a PEEP of 0.2 kPa. Oleic acid (dissolved 1∶1 in 96% alcohol) was administered in a series of multiple injections of 0.1 ml until $$P_{aO_2 } $$ was lower than 8 kPa. Measurements and results Careful titration of the oleic acid injections on guidance of the $$P_{aO_2 } $$ established a reproducible respiratory distress ( $$P_{aO_2 } $$ =7.3±0.8 kPa), in which gas exchange and hemodynamic variables were stable for at least 4 h. The number of oleic acid injections (22±11, mean and SD) varied between the animals. Conclusions With the use of multiple injections of oleic acid, a stable model of early respiratory distress in pigs can be achieved, in spite of individual differences in sensitivity. Such a stable model allows for a diversity of studies on early respiratory distress.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Intensive care medicine 21 (1995), S. 1009-1015 
    ISSN: 1432-1238
    Keywords: Alternating ventilation ; Cardiac output ; Central venous pressure
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Objective We tested whether alternating ventilation (AV) of each lung (i.e. with a phase difference of half a ventilatory cycle) would decrease central venous pressure and so increase cardiac output when compared with simultaneous ventilation (SV) of both lungs. Theory If, during AV, the inflated lung expands partly via compression of the opposite lung, mean lung volume will be smaller during AV than SV. As a consequence, mean intrathoracic pressure (as cited in the literature), and therefore, central venous pressure will be smaller. Design The experiments were performed in seven anaesthetized and paralyzed piglets using a double-piston ventilator. Minute ventilation was the same during AV and SV. Starting at SV, we alternated three times between AV and SV for periods of 10 min. Results During AV, central venous pressure was decreased by 0.7 mmHg and cardiac output was increased by 10±4.4% (mean, ±SD) compared with SV. AV also resulted in increased arterial pressure. During one-sided inflation with closed outlet of the opposite lung, a pressure rise occurred in the opposite lung, indicating compression. Conclusion The higher cardiac output during AV than SV can be explained by the fact that central venous pressure is lower during AV. This lower central venous pressure is very probably due to the lower mean intrathoracic pressure caused by compression of the opposite lung during unilateral inflation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993), S. 213-219 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The aim of this study was to investigate the bone response to three different types of titanium (Ti) alloys and hydroxyapatite (HA) coated titanium alloy by histological and histomorphometrical analysis. Therefore, implants made of these materials were inserted into the tibia of rabbits. Implantation times were 6 and 16 weeks. The histological evaluation included measurement of the amount of bone apposition and analysis of the bone reaction and interface characteristics around the implants. The results demonstrated no marked differences in bony reaction to the different implant materials. In addition, the HA coatings showed loss of thickness. © 1993 John Wiley & Sons, Inc.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Chemie Ingenieur Technik - CIT 66 (1994), S. 1229-1230 
    ISSN: 0009-286X
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Plasma-sprayed ceramic coatings of fluorapatite (FA), magnesiumwhitlockite (MW), and hydroxylapatite (HA), and noncoated Ti-6Al-4V alloy (Ti) implants were evaluated histologically and histomorphometrically in a goat animal study. Cylindrical Ti-6Al-4V plugs were plasma-spray-coated with FA, MW, and HA. Noncoated, gritblasted Ti plugs served as controls. The plugs were implanted into the right femur and left humerus of 20 adults goats. The results were evaluated using descriptive histology and histomorphometry. The histomorphometry consisted of measurements of bone apposition and coating thickness. The results demonstrated that FA showed a high amount of bone apposition without signs of degradation or dissolution. MW showed considerable reduction in thickness and at 12 weeks an adverse tissue reaction. However, at 25 weeks the amount of bone apposition was significantly increased compared with the 12-week implants. HA revealed considerable and progressive reduction in thickness and at 25 weeks a lower amount of bone apposition than FA and MW. At 12 weeks the Ti implants did reveal bone apposition, although frequently localized fibrous tissue was visible. At 25 weeks the Ti implants did not differ in bone apposition from the HA implants. Further studies are necessary on the effect of degradation or dissolution of HA on the compatibility with bone. © 1993 John Wiley & Sons, Inc.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 28 (1994), S. 1047-1054 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: This study reports on the soft-tissue response to titanium fiber mesh percutaneous implants. The implants were inserted in the backs of 15 rabbits. The surgical procedure was performed in two steps: implantation of the subcutaneous part of the implants and, after 3 months, fixation of the percutaneous part into the subcutaneous part. Two and 6 months after insertion the animals were sacrificed and the implants, with their surrounding tissues, were processed histologically. Light microscopic analysis demonstrated that only one implant showed considerable skin retraction in the percutaneous area. Around the rest of the implants no downgrowth or only a very limited epidermal downgrowth was observed. Furthermore, the fiber mesh material showed good biocompatible behavior. These results confirm the previous finding that sintered titanium fiberweb structures are effective for the stabilization of percutaneous devices located in soft tissues and can improve their performance. © 1994 John Wiley & Sons, Inc.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A rat bone marrow cell culture was used to evaluate the osteogenic potential of amorphous and crystalline thin calcium phosphate (Ca/P) coatings. The coatings were deposited on titanium discs using a radiofrequency magnetron sputter procedure. Amorphous and crystalline plasma spray Ca/P coated and noncoated titanium discs served as reference material. The cellular behavior was analyzed with quantitative (attachment and proliferation rates) and qualitative (scanning electron microscopy) techniques. No significant differences were found in cell attachment and proliferation rates between the various materials. Scanning electron microscopy showed extracellular matrix formation after 18 days of culture on amorphous plasma-sprayed and the two types of magnetron sputtered coatings. Furthermore, no severe degradation of the magnetron sputtered coatings was observed. They even appeared to induce apatite formation. On basis of the results, we conclude that magnetron sputtering appears to be a promising method to manufacture bioactive ceramic coatings. © 1995 John Wiley & Sons, Inc.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 37 (1997), S. 539-547 
    ISSN: 0021-9304
    Keywords: in vivo ; soft-tissue reaction ; scanning electron microscopy ; confocal laser scanning microscopy ; three-dimensional reconstruction ; implant interface ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: It has been suggested that during wound healing microtextured surfaces can alter events at the interface between implant surface surface and surrounding tissues. To investigate this phenomenon, smooth and microtextured silicone rubber implants were implanted subcutaneously in rabbits for 3, 7, 42, and 84 days. The textured implants possessed parallel surface microgrooves and ridges with a width of 2.0, 5.0, and 10.0 μm. All grooves had a depth of approximately 0.5 μm. SEM observation showed fibroblasts, erythrocytes, lymphocytes, macrophages, fibrin, and collagen on all implant surfaces after 3 and 7 days. After 42 and 84 days only little collagen, a small number of fibroblasts, but no inflammatory cells were seen on the implant surfaces. The fibroblasts were not oriented along the surface grooves on all textured surfaces. Three-dimensional reconstruction of CLSM images and LM images showed no significant differences between the thickness of the capsules surrounding the smooth and those surrounding the microgrooved implants. In contrast, LM did show a significantly lower number of inflammatory cells and a significantly higher number of blood vessels in the capsules surrounding the microgrooved implants. Differences between the 2.0, 5.0, and 10.0 μm grooved implants were not detected. Our results concerning the capsule thickness suggest that the depth of our grooves was not sufficient to facilitate mechanical interlocking, but the cause for the observed differences in inflammatory response and number of blood vessels remains unclear. © 1997 John Wiley & Sons, Inc. J Biomed Mater Res, 37, 539-547, 1997.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...