Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Chemistry  (29)
  • Mechanical ventilation  (4)
  • Alternating ventilation  (2)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Intensive care medicine 22 (1996), S. 813-817 
    ISSN: 1432-1238
    Keywords: Alternating ventilation ; Cardiac output ; Central venous pressure ; Intrathoracic pressure ; Lung volume ; Pericardial pressure
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Objective We tested the hypothesis that mean thoracic expansion (and mean lung volume) is lower during alternating ventilation (AV), i.e. ventilation of both lungs with a phase shift of half a ventilatory cycle, compared to synchronous ventilation (SV) of both lungs. As a consequence, intrathoracic pressure will be lower, causing lower, central venous pressure and higher cardiac output. Design In eight anaesthetized and paralysed piglets, differential ventilation was established by fixation of an endobronchial tube in the left main bronchus. SV and AV were sequentially applied for four and three periods, respectively, of 10 minutes each. Minute ventilation was the same during AV and SV and adapted to normocapnia. Two series of observations were performed: series 1 with intact thorax and monitoring of oesophageal pressure; series 2 after perforation of the sternum, airtight closure of the thorax and monitoring of pericardial pressure. Results In both series, mean lung volume was 16±4% lower and central venous, oesophageal (series 1) and pericardial pressures (series 2) were 0.5±0.7 mmHg lower during AV compared to SV (allp〈0.001). In series 1, aortic pressure was 5 mmHg and cardiac output 8% higher (bothp〈0.001). In series 2, cardiac output was 5% higher during AV (p〈0.001), but aortic pressure did not change (p=0.07). Conclusion Our data verified the hypothesis. The lower oesophageal (series 1), pericardial (series 2) and central venous pressures during AV compared to SV could be explained by the smaller thoracic expansion due to the lower mean lung volume, which was attributed to compression of the opposite lung by the expansion of the inflated lung.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Intensive care medicine 12 (1986), S. 71-79 
    ISSN: 1432-1238
    Keywords: Cardiac output ; Flow modulation ; Mechanical ventilation ; Thermodilution method
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The reliability of cardiac output estimation by thermodilution during artificial ventilation was studied in anesthetized pigs at the right side of the heart. The estimates exhibited a cyclic modulation related to the ventilation. The amplitude of the modulation was independent of the level of positive end-expiratory pressure, ventilatory pattern and volemic loading of the animals. However, a non-constant phase relation existed between the ventilatory cycle and the modulation. Single observations at a fixed moment in the ventilatory cycle are therefore not appropriate for estimation of mean cardiac output nor for studying its relative changes. The averaging of estimates spread equally over the ventilatory cycle led to a much larger reduction in the deviation of the averages from the mean cardiac output than an averaging procedure of randomly selected estimates. The accracy of estimation of mean cardiac output by two estimates equally spread in the ventilatory cycle was equal to the accuracy obtained by averaging five randomly selected estimates. Averaging four estimates, equally spread in the cycle, appeared to be the optimal procedure. For 89% of all averages an accuracy of 5% around the mean was obtained and for 99% an accuracy of ±10%.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-1238
    Keywords: Cardiac output ; Mechanical ventilation ; Multiple injections ; Thermodilution
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The application of the thermodilution method in conditions associated with variations in blood flow implies a misuse of the Stewart Hamilton equation. Therefore, we studied the reliability of the thermodilution method for the estimation of mean cardiac output (CO) during mechanical ventilation in patients (n=9). Variation of the injection moment in the ventilatory cycle elicited a cyclic variation of CO estimates. This variation was not the same for all patients neither in phase nor in amplitude. Therefore, no specific phase in the ventilatory cycle could be selected for an accurate estimation of mean CO. Averaging CO estimates randomly distributed in the ventilatory cycle led to an improvement of accuracy with the square root of the number of observations. The averaging of CO estimates spread equally over the ventilatory cycle led to a much better result, e.g., the variation in the average of two estimates equally spread in the ventilatory cycle was similar to the variation in the average of four random estimates. We conclude that averaging of 3 or 4 estimates spread equally over the ventilatory cycle is an adequate strategy to estimate mean cardiac output in patients reliably.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Intensive care medicine 21 (1995), S. 1009-1015 
    ISSN: 1432-1238
    Keywords: Alternating ventilation ; Cardiac output ; Central venous pressure
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Objective We tested whether alternating ventilation (AV) of each lung (i.e. with a phase difference of half a ventilatory cycle) would decrease central venous pressure and so increase cardiac output when compared with simultaneous ventilation (SV) of both lungs. Theory If, during AV, the inflated lung expands partly via compression of the opposite lung, mean lung volume will be smaller during AV than SV. As a consequence, mean intrathoracic pressure (as cited in the literature), and therefore, central venous pressure will be smaller. Design The experiments were performed in seven anaesthetized and paralyzed piglets using a double-piston ventilator. Minute ventilation was the same during AV and SV. Starting at SV, we alternated three times between AV and SV for periods of 10 min. Results During AV, central venous pressure was decreased by 0.7 mmHg and cardiac output was increased by 10±4.4% (mean, ±SD) compared with SV. AV also resulted in increased arterial pressure. During one-sided inflation with closed outlet of the opposite lung, a pressure rise occurred in the opposite lung, indicating compression. Conclusion The higher cardiac output during AV than SV can be explained by the fact that central venous pressure is lower during AV. This lower central venous pressure is very probably due to the lower mean intrathoracic pressure caused by compression of the opposite lung during unilateral inflation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1432-2013
    Keywords: Venous return ; Central venous pressure ; Inspiratory pause procedures ; Venous capacity ; Venous resistance ; Mechanical ventilation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract In eight mechanically ventilated, anaesthetized pigs weighing 10.3 ± 0.8 kg (mean ± SD) we studied the effect of the inflation time of the lung on the estimation of the mean systemic filling pressure (P sf) from the changes in venous return and central venous pressure during inflation of the lung. For this purpose we applied slow inflation procedures (SIP) to the lung with inflation times of 2.4, 4.8, 7.2, 9.6 and 12 s at tidal volumes (V T) of 15 and 30 ml/kg. The data were compared with the values ofP sf obtained from inspiratory pause procedures (IPPs). A linear regression between venous return and central venous pressure applied during a SIP underestimatedP sf compared with the value obtained with IPPs. An exponential fit through the values ofP sf obtained from the different SIPs predicted an inflation time of about 15 s for an estimation ofP sf that is not different from theP sf (IPP). The advantage of the SIP method is that theP sf can be determined much faster than with the method based on IPPs. However, due to the rather long inflation time needed, the method may be only applicable under circumstances where neurohumoral control mechanisms are suppressed as during intensive care and anaesthesia.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1432-2013
    Keywords: Key words Venous return ; Central venous pressure ; Inspiratory pause procedures ; Venous capacity ; Venous resistance ; Mechanical ventilation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract In eight mechanically ventilated, anaesthetized pigs weighing 10.3 ± 0.8 kg (mean ± SD) we studied the effect of the inflation time of the lung on the estimation of the mean systemic filling pressure (P sf) from the changes in venous return and central venous pressure during inflation of the lung. For this purpose we applied slow inflation procedures (SIP) to the lung with inflation times of 2.4, 4.8, 7.2, 9.6 and 12 s at tidal volumes (V T) of 15 and 30 ml/kg. The data were compared with the values of P sf obtained from inspiratory pause procedures (IPPs). A linear regression between venous return and central venous pressure applied during a SIP underestimated P sf compared with the value obtained with IPPs. An exponential fit through the values of P sf obtained from the different SIPs predicted an inflation time of about 15 s for an estimation of P sf that is not different from the P sf (IPP). The advantage of the SIP method is that the P sf can be determined much faster than with the method based on IPPs. However, due to the rather long inflation time needed, the method may be only applicable under circumstances where neurohumoral control mechanisms are suppressed as during intensive care and anaesthesia.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993), S. 213-219 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The aim of this study was to investigate the bone response to three different types of titanium (Ti) alloys and hydroxyapatite (HA) coated titanium alloy by histological and histomorphometrical analysis. Therefore, implants made of these materials were inserted into the tibia of rabbits. Implantation times were 6 and 16 weeks. The histological evaluation included measurement of the amount of bone apposition and analysis of the bone reaction and interface characteristics around the implants. The results demonstrated no marked differences in bony reaction to the different implant materials. In addition, the HA coatings showed loss of thickness. © 1993 John Wiley & Sons, Inc.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Chemie Ingenieur Technik - CIT 66 (1994), S. 1229-1230 
    ISSN: 0009-286X
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Plasma-sprayed ceramic coatings of fluorapatite (FA), magnesiumwhitlockite (MW), and hydroxylapatite (HA), and noncoated Ti-6Al-4V alloy (Ti) implants were evaluated histologically and histomorphometrically in a goat animal study. Cylindrical Ti-6Al-4V plugs were plasma-spray-coated with FA, MW, and HA. Noncoated, gritblasted Ti plugs served as controls. The plugs were implanted into the right femur and left humerus of 20 adults goats. The results were evaluated using descriptive histology and histomorphometry. The histomorphometry consisted of measurements of bone apposition and coating thickness. The results demonstrated that FA showed a high amount of bone apposition without signs of degradation or dissolution. MW showed considerable reduction in thickness and at 12 weeks an adverse tissue reaction. However, at 25 weeks the amount of bone apposition was significantly increased compared with the 12-week implants. HA revealed considerable and progressive reduction in thickness and at 25 weeks a lower amount of bone apposition than FA and MW. At 12 weeks the Ti implants did reveal bone apposition, although frequently localized fibrous tissue was visible. At 25 weeks the Ti implants did not differ in bone apposition from the HA implants. Further studies are necessary on the effect of degradation or dissolution of HA on the compatibility with bone. © 1993 John Wiley & Sons, Inc.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 28 (1994), S. 1047-1054 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: This study reports on the soft-tissue response to titanium fiber mesh percutaneous implants. The implants were inserted in the backs of 15 rabbits. The surgical procedure was performed in two steps: implantation of the subcutaneous part of the implants and, after 3 months, fixation of the percutaneous part into the subcutaneous part. Two and 6 months after insertion the animals were sacrificed and the implants, with their surrounding tissues, were processed histologically. Light microscopic analysis demonstrated that only one implant showed considerable skin retraction in the percutaneous area. Around the rest of the implants no downgrowth or only a very limited epidermal downgrowth was observed. Furthermore, the fiber mesh material showed good biocompatible behavior. These results confirm the previous finding that sintered titanium fiberweb structures are effective for the stabilization of percutaneous devices located in soft tissues and can improve their performance. © 1994 John Wiley & Sons, Inc.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...