Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Analytical Chemistry and Spectroscopy  (1,947)
  • Industrial Chemistry  (521)
  • Computational Chemistry and Molecular Modeling  (408)
Material
Keywords
  • 1
    ISSN: 0935-6304
    Keywords: Proteomics ; protein analysis ; multidimensional HPLC ; ion-exchange chromatography ; reversed phase chromatography ; comprehensive HPLC ; two-dimensional HPLC ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---The interactive modes of High Performance Liquid Chromatography (HPLC) of proteins provide a platform for the construction of a multidimensional HPLC system coupled to mass spectrometry. We present a system composed of both anion and cation exchanger columns, in the first dimension, and n-octadecyl bonded 1.5 μm nonporous silica columns in the second dimension. Both columns are operated under gradient conditions. A system suitability test with standard proteins showed that the total analysis can be performed within about 20 minutes. The fractions taken from the ion exchanger column are directly analyzed within one minute on the reversed phase column at a high flow rate. Two reversed phase columns are applied and operated alternatively: while the first column performs the separation within one minute, the analytes leaving the first dimension are enriched in an on-column focusing mode on top of the second column. The sample clean-up and enrichment is performed on a novel type of restricted access cation exchanger column with internal sulfonic acid groups and external diol groups. The columns exhibit a molecular weight exclusion limit for globular proteins of about 15 kDa. Our next studies will be directed towards the analysis of proteins and peptides from extracts of fibroblasts.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Organic Magnetic Resonance 17 (1981), S. 301-302 
    ISSN: 0030-4921
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Carbon-13 signal assignments of the labdane diterpenoids phlogantholide-A, its diacetate and isophlogantholide-A are reported. The assignments of the 13C NMR signals of 14-deoxyandrographolide and its diacetate, made earlier, have now been confirmed by lanthanide shift studies on the former and also by 13C spectral studies on anhydroandrographolide diacetate and 14-deoxy-11,12-didehydroandrographolide diacetate.
    Additional Material: 1 Tab.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 0306-042X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A gas chromatographic mass spectrometric assay using selected ion monitoring is described which permits the determination of trifluoperazine in plasma at concentrations ranging from 0.078 to 5.0 ng ml-1. It relies on the extraction of trifluoperazine and the internal standard, prochlorperazine or the tetradeuterated analogue of trifluoperazine, form basified plasma with a n-pentane/2-propanol solvent mixture. Following the evaporation of organic solvent, the residue is reconstituted in a small volume of methanol. Suitable aliquots were anlysed by the combined technique of gas chromatography/electron impact mass spectrometry with a data system. The described procedure is specific and enables the quantitation of 78 pg ml-1 of the drug with a coefficient of variation 〈7%. The method has demonstrated sufficient sensitivity to permit pharmacokinetic and bioavailability studies after a single 5 mg oral dose.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    International Journal of Quantum Chemistry 18 (1980), S. 393-396 
    ISSN: 0020-7608
    Keywords: Computational Chemistry and Molecular Modeling ; Atomic, Molecular and Optical Physics
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A brief account of a quantum chemistry literature data base (QCLDB) is described, which contains the key information of about 2000 papers of ab initio calculations of atoms and molecules published in 1977-1979. The QCLDB is stored in a computer and can be sorted and rearranged into author and substance indices. Selection of the items for each paper in a computer-readable data base is discussed.
    Additional Material: 1 Tab.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    International Journal of Quantum Chemistry 7 (1973), S. 1029-1031 
    ISSN: 0020-7608
    Keywords: Computational Chemistry and Molecular Modeling ; Atomic, Molecular and Optical Physics
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: To gather more information on stereochemical factors in the hepatic disposition of organic cations, mass spectrometry coupled to liquid chromatography was used to determine the identity of the metabolites excreted in bile after isolated rat liver perfusions with the quaternary ammonium derivatives of the enantiomeric drugs dextrorphan and levorphanol. Ionspray mass spectrometry was chosen for its soft ionization and absence of thermal degradation of labile compounds. The drugs were labelled with a stable (2H) isotope and mixed with unlabelled drugs to create an artificial isotope pattern in the mass spectrum and facilitate the recognition of unknown metabolites. In mass spectra that were recorded under normal conditions, fragmentation was absent and metabolites of N-methyl dextrorphan and N-methyl levorphanol were visible as parent-ion ‘doublets’. Collision-induced fragmentation studies were performed to support the identification of the metabolites. For N-methyl dextrorphan the glucuronide, the glutathione conjugate and the glucuronide of the N-demethylated metabolite were found in bile. For N-methyl levorphanol the glucuronide, the glutathione conjugate, the sulphate conjugate and the glucuronide of a hydroxylated N-methyl levorphanol were excreted in bile. Thus a remarkable stereoselectivity occurs in the metabolism of these quaternary ammonium compounds in the rat liver.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: This study demonstrated the utility of negative ion atomospheric pressure ionization mass spectrometry for the routine quantitation of 2,4,5-trichlorophenoxyacetric acid and its glycine and taurine amide metabolites in mouse blood, urine and feces samples. The quantitation of 2,4,5-trichlorophenoxyacetic acid in blood follows a short cleanup procedure and used 2,4,5-trichlorophenoxy-13C6-acetic acid as the stable label isotope diluent. A more extensive cleanup procedure utilizing high-pressure liquid chromatography was required for the determination of 2,4,5-trichlorophenoxyacetic acid and its two metabolites in urine and feces. The glycine amide metabolite was quantitated by the 13C stable label isotope diluent method. The taurine amide relied on an initial separation step followed by using a second 2,4,5-trichlorophenoxy-13C6-acetic acid spike for its isotope diluent. Alkaline hydrolysis of the metabolites, followed by methylation, allowed the methyl ester of 2,4,5-trichlorophenoxyacetic acid to be solely used as the analyte in the negative ion atmospheric pressure ionization mass spectrometry quantitation step.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 20 (1991), S. 493-497 
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A sensitive and rapid method to analyse fuel components in blood from rats exposed to kerosene or light oil vapour was developed by making use of capillary gas chromatography/mass spectrometry. The aliphatic hydrocarbons with carbon numbers 8-10 and aromatics such as toluene, xylene, 3- and 4-ethyltoluene and trimethylbenzenes were clearly detected in blood from rats exposed to kerosene or light oil vapour, using the head-space method combined with the salting-out technique. The concentration ratio of pseudocumene to toluene in blood exposed to light oil was higher than that in the case of exposure to kerosene. The lower limits of detection were 50 pg and 1 ng in toluene and pseudocumene, respectively. Our suggestion is that this method is useful in forensic investigations to detect fuel components in blood and for the purposes of differentiating kerosene and light oil in blood tissues.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Chemie Ingenieur Technik - CIT 35 (1963), S. 631-637 
    ISSN: 0009-286X
    Keywords: Chemistry ; Industrial Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Aus einer größeren Anzahl von errechneten Gleichgewichtszusammensetzungen und thermodynamischen Größen für Hochtemperatur-Plasmen teilen wir als Beispiel einige Diagramme mit für Argon und Kohlenstoff-Verbindungen1. Wir begründen das von uns benutzte Formelsystem und geben Fließbilder für den Rechenweg an, nach denen die Aufgabe für andere elektronische Ziffernrechenanlagen als die hier benutzte programmiert werden kann.
    Additional Material: 13 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Chemie Ingenieur Technik - CIT 36 (1964), S. 1103-1104 
    ISSN: 0009-286X
    Keywords: Chemistry ; Industrial Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Mit Amalgamen verschiedener Metalle, die eine hohe Sauerstoff-Affinität besitzen, läßt sich bei Raumtemperatur in inerten und reduzierenden Gasen der Restsauerstoff auf 10-25 Vol.-% absenken. Es werden hierfür einiache Apparaturen beschrieben.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...