Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Analytical Chemistry and Spectroscopy  (48)
  • Etonitazene reinforcement
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Psychopharmacology 64 (1979), S. 1-7 
    ISSN: 1432-2072
    Keywords: Etonitazene ; Etonitazene reinforcement ; Concurrent schedules ; Choice procedures ; Rats ; Taste ; Olfaction ; Auditory stimuli ; Discriminative stimuli ; Conditioned reinforcers ; Fixed-ratio schedules
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Etonitazene and water were concurrently available to four rats during daily 1 h sessions in operant conditioning chambers equipped with two levers and two liquid dippers. A food-induced training procedure was used whereby etonitazene drinking was rapidly established by presenting rats with gradually increased drug concentrations with their daily food ration. When food was subsequently removed from the session and given post-session, etonitazene responding persisted. The rats were subsequently trained on fixed-ratio (FR) schedules with concurrent access to etonitazene and water. The number of dipper presentations compared with etonitazene concentrations (0.078–10.0 μg/ml) resulted in a typical inverted U-shaped function while etonitazene intake (μg/kg) increased directly with concentration. After drinking large quantities of etonitazene the rats showed ataxia, hyper-activity, and stereotypy. Extinction tests demonstrated that rats could discriminate between etonitazene and water on the basis of one dipper full of each liquid; the amount of etonitazene in one dipper was 0.0078 μg. Further tests showed that this discrimination was based on taste or immediate post-ingestional feedback rather than olfactory cues. An auditory stimulus was presented concurrently with responses on the drug lever; however, there was no difference in responding for the drug in the presence or absence of this stimulus except at the lowest concentration. After the extinction tests, when the lowest drug concentration was again available with concurrent water, responding was substantially higher in the presence of stimulus associated with availability of etonitazene. The results extend previous work on oral narcotic intake to a lever-press concurrent choice procedure which is sensitive to reinforcing effects of the drug at low concentrations.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-2072
    Keywords: Etonitazene reinforcement ; Oral selfadministration ; Food deprivation ; Food access ; Concurrent schedules ; Rats
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Recent research has shown that food deprivation increases drug self-administration in rats and rhesus monkeys. The purpose of the present study was to examine two variables related to this food-deprivation effect: maintenance of rats at reduced body weights and the absence of food. Etonitazene HCl was established as a reinforcer orally for 12 rats according to procedures previously used in experiments reported by this laboratory. Lever-pressing behavior was maintained under fixed-ratio (FR) schedules during daily 1-h sessions by etonitazene or water, which were available either concurrently or on alternating days. In the first experiment, six rats were maintained at 75% of their free-feeding weights. The effect of presenting the daily food allotment at 23, 4, 2, 1, or 0 h before their daily drug or water self-administration session was studied. When the rats were fed 23, 4, or 2 h before the session, etonitazene dipper presentations were at maximum levels and were substantially higher than for water. When the rats were fed during (0) or 1 h before the session, the number of etonitazene dipper presentations was lower, but it exceeded those for water. Under conditions of complete food satiation (0 h deprived-100% body weight), etonitazene and water dipper presentations were both low, and there were no differences between them. In the second experiment, six rats maintained at 75% of their free-feeding weights were trained to respond for etonitazene or water on alternating days. When they were subsequently food satiated (100% body weight), drug- and water-maintained behavior decreased to low levels. These rats were then deprived of food for 4 or 16 h before their daily 1-h session, and responding did not increase. Body weight did not decrease below 100%. These results suggest that maintenance at reduced body weight rather than the absence of food is the determinant of increased rates of drug-reinforced behavior.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Psychopharmacology 59 (1978), S. 225-229 
    ISSN: 1432-2072
    Keywords: Rhesus monkeys ; Etonitazene HCl ; Etonitazene concentration ; Etonitazene reinforcement ; Fixed-ratio schedules ; Etonitazene drinking ; Oral self-administration
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Drinking of etonitazene HCl was studied in three rhesus monkeys during daily 3-h sessions. As the drug concentration was increased, the number of liquid deliveries decreased, and etonitazene intake (μg/kg body weight) increased. As fixed-ratio (FR) requirements were increased, rate of responding increased, and liquid deliveries slightly decreased. When water was substituted for the drug, there was a large increase in responding for several sessions, followed by a slow decline to low rates. When etonitazene was reintroduced, responding abruptly increased to previous drug levels. These data suggest that etonitazene can serve as a positive reinforcer when taken orally by rhesus monkeys.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 15 (1988), S. 193-204 
    ISSN: 0887-6134
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A method which involves the use of tandem mass spectrometry (MS/MS) for the identification of drug metabolites has been demonstrated with a triple quadrupole mass spectrometer. The method is based on the fact that metabolites usually retain various substructures of the original drug molecule. MS/MS is capable of rapidly identifying molecules with characteristic substructures without prior separation. It is shown that this method makes it possible to postulate possible drug metabolite structures rapidly and systematically without the use of standards. The MS/MS method, as it was applied to the identification of the metabolites of a new antiepileptic drug, zonisamide, is discussed. In this case it was possible to identify isomeric metabolites due to their differences in vaporization times off the probe and their different daughter spectra. The complementary uses of the neutral loss and parent scans for the determination of the site of metabolism is demonstrated. A new figure of merit, the limit of identification, is introduced. The amount of the epoxide metabolite of carbamazepine necessary for its reliable identification in urine was shown to be 0.4 ng/μl. The application of various techniques to confirm preliminary findings with this MS/MS method are described.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 16 (1993), S. 52-52 
    ISSN: 0935-6304
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 29-32 
    ISSN: 0935-6304
    Keywords: Capillary electrochromatography ; electroosmotic flow ; frit ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The formation of bubbles in capillary electrochromatography (CEC) is well documented: possible origins include Joule heating and variations in EOF velocity on passing from the stationary phase through the frit and into the open tube. Methods for the prevention of bubble formation are discussed which are confirmed by experimental results. Using frit lengths varying from 1 mm to 6 mm it is shown how frit length is directly related to the likelihood of bubble formation and how this is affected by applied voltage. It is shown that the change in applied voltage across a capillary affects the formation of bubbles and also that rebonding octadecylsilane (ODS) onto the silica frit after formation of the frit can minimize the formation of bubbles and how this effects the chromatography. A method is also described for increasing the robustness of silica capillaries using a column coupler along with modifications made to conventional capillary electrophoresis equipment to cater for CEC.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 15 (1992), S. 478-479 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Kováts retention index ; GW-BASIC program ; Computer-assisted calculation ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 7 (1984), S. 144-146 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary column ; Cyclopentolate ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 29 (1994), S. 329-332 
    ISSN: 0030-493X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 2 (1988), S. 275-276 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...