Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    The visual computer 2 (1986), S. 159-163 
    ISSN: 1432-2315
    Keywords: Education ; Animation ; Computer graphics ; Physics ; Solar system
    Source: Springer Online Journal Archives 1860-2000
    Topics: Computer Science
    Notes: Abstract Within the Jet Propulsion Laboratory in Pasadena, California, state of the art computer graphics animation is done in the Computer Graphics Laboratory. The topics of the animations cover many scientific disciplines. Specific features of the system developed there, both hardware and software, are discussed. The prime mover of the effort is Dr. James F. Blinn of Pasadena; his role and experiences are elaborated. Their current largest project is The Mechanical Universe; the system is used for its production.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 20 (1997), S. 643-646 
    ISSN: 0935-6304
    Keywords: Capillary electrophoresis ; Electogenerated chemiluminescence ; Ru(bpy)32+ ; Tripropylamine ; Proline ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A post- column chemiluminescent technique for thedetection of compounds that are poor chromoshores using electorogenerated chemiluminescence following separation by capillartgy electrophoresis is described. The luminrescent signal is generated followintg the reaction of anlyres (e.g. amines) with Ru(bpy)33+, which isx electrochemically generated post-columan from Ru(bpy)32+. Tripropylamine and proline are used as two model compounds to demostrate the feasibility of the method. Detection limits for the prototype system were in the micromolar rage, suggesting that this technnique offers an alternative to indirect detection of compounds that are poor chromophores with an added selectivity advangage. The system includes the use of a conductive joint to isolate the separation field from the potential necessary to drive the elctrogenerated chemiluminescent reactiion. Addition of the chemiluminescent reagent Ru(bpy)32+ post-column did not decrease the efficiency of the separation. The design and favrication of the novel cell is discussed.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 14 (1991), S. 294-296 
    ISSN: 0935-6304
    Keywords: High performance liquid chromatography ; Preservation of a π-system for specific detection ; Unconventional quantification technique ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Tab.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 17 (1994), S. 731-732 
    ISSN: 0935-6304
    Keywords: Micellar electrokinetic chromatography ; Lanthanide luminescence ; Steroids ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 15 (1992), S. 505-509 
    ISSN: 0935-6304
    Keywords: Unified chromatography ; Gas chromatography ; Supercritical fluid chromatography ; Open tubular column ; Injection technique ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A unified approach to sequential gas and supercritical fluid Chromatography using 50 μm i.d. open tubular columns is described. Sample introduction is performed by means of a rotary injection valve. In order that linear velocities can be optimized independently, a second rotary valve in the chromatographic oven is used to direct the flow of column eluate to the flame ionization detector through either fused silica tubing in GC, or a frit restrictor in SFC.Applications of sequential GC-SFC on a 50 μm i.d. open tubular column are demonstrated, and comparisons made between sequential GC-SFC on 50 and 100 μm i.d. columns.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 15 (1992), S. 526-530 
    ISSN: 0935-6304
    Keywords: Coupled LC-GC ; Diesel exhaust particulate matter ; Oxy-PAH ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Emissions from diesel engines contain mutagenic compounds, many of which are derivatives of polycyclic aromatic hydrocarbons. The complexity of extracts of particulate matter requires multi-stage chromatographic analysis performed off-line.In this study, coupled LC-GC is presented as an alternative method for the analysis of the polar fraction of extracts of diesel particulate matter. Preseparation of the sample was achieved by normal phase HPLC and fractions were transferred to the GC through an on-column interface. Through selective transfer, extensive characterization of the extract is possible and chromatograms can be greatly simplified, thus aiding identification.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part B: Polymer Physics 36 (1998), S. 567-572 
    ISSN: 0887-6266
    Keywords: surface ; interfaces ; diffusion ; polystyrene ; polyphenylene oxide ; Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: Symmetric polydisperse (Mw = 23 × 104, Mw/Mn = 2.84) and monodisperse (Mw = 21 × 104, Mw/Mn 〈 1.05) polystyrene (PS), and asymmetric polydisperse PS/poly(2,6-dimethyl 1,4-phenylene oxide) (PPO) interfaces have been bonded in the vicinity of the glass transition temperature (Tg) of PS. In a lap-shear joint geometry, strength develops in all cases with time to the fourth power, which indicates that it is diffusion controlled. Strength developing at short times at the polydisperse PS/PS interface, at 90°C, is higher than that at the monodisperse interface, at 92°C (at Tg - 13°C in both cases), presumably due to the contribution of the low molecular weight species. The decrease of strength at the PS/PPO interface when the bonding temperature decreases from 113 to 70°C, i.e., from Tg + 10°C to Tg - 33°C of the bulk PS, indicates a high molecular mobility at the surface as compared to that in the bulk, and can be expressed by a classical diffusion equation, which is valid above Tg (of the surface layer). © 1998 John Wiley & Sons, Inc. J Polym Sci B: Polym Phys 36: 567-572, 1998
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A mass fragmentographic method for simultaneous measurement of unlabeled and deuterium labeled methadone in human plasma is described. This specific method has a lower sensitivity of about 16 pmol/ml with a coefficient of variation of less than 4%. The usefulness of the method was evaluated in studies on opiate dependent subjects undergoing methadone maintenance treatment. In one application methadone-d3 was given as a pulse dose during continuous treatment with unlabeled methadone and plasma levels of both species followed by mass fragmentography. The method will be of value in the study of methadone pharmacokinetics in the steady state and in other in vivo situations where multiple drug pools must exist.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A quantitative mass fragmentographic method for the simultaneous determination of labeled and unlabeled propoxyphene in plasma is described. Dogs treated daily with propoxyphene-d0 were treated with a pulse dose of propoxyphene-d2 at day 20. It was found that following an initial rapid equilibrium phase levels of propoxyphene-d2 fell more rapidly than those of propoxyphene-d0. This result suggests that ‘deep’ pools of tissue bound propoxyphene exist which exchange very slowly with drug present in the central compartment. Experimental evidence is presented which demonstrates that the difference in behavior of propoxyphene-d0 and -d2 is not due to unanticipated secondary isotope effects.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 3 (1976), S. 217-225 
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Through the combined use of stable isotope labeling and gas chromatographic mass spectrometric analysis, the metabolic patterns for propoxyphene have been determined in laboratory animals and man. The rat and dog eliminated propoxyphene and its metabolites principally via the bile, while the rabbit more closely resembled man in excreting the metabolic products into urine. Metabolites in rat and rabbit existed as conjugates, whereas in dog and man the metabolites were excreted as a mixture of the free and unconjugated forms. The primary route of metabolism in all species studied was N-demethylation. However, the rat and rabbit extensively hydroxylated propoxyphene and its metabolltes prior to elimination. Metabolites arising from ester hydrolysis were found in rat and man. N-acetylated products were identified in all four species. A metabolite formed from cyclization and dehydration of dinorpropoxyphene was isolated in urine and was further identified as a circulating metabolite in dog plasma.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...