Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Analytical Chemistry and Spectroscopy  (1)
  • spinal canal  (1)
Material
Years
Keywords
  • 1
    ISSN: 1432-1920
    Keywords: Vertebral artery ; myelography ; spinal canal ; cranial artery
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary In a review of the vertebral angiograms of 300 patients free from disease at the craniovertebral junction, we found atlantoaxial arterial anomalies in 2,3%. These were: 2 cases in which the vertebral artery ran in the spinal canal below C1, 3 cases of duplication of the vertebral artery above and below C1, and 2 cases of origin of the posterior inferior cerebellar artery at C2. Although these arteries ran in the spinal canal between C1 and C2, they never encroached upon the posterior third of the canal. From the survey of another 21 patients having bony abnormalities at the craniovertebral junction, the first type of arterial anomaly described above was seen in 4 patients and associated with failure of segmentation of the embryonic sclerotome such as occipitalization of the atlas or Klippel-Feil syndrome. It is possible to relate the development of these anomalous vessels to malarrangement of the embryonic segmental arteries. Our results indicate that one must be cautious with lateral C1/2 puncture or surgical exposure of the region.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 3 (1970), S. 1341-1348 
    ISSN: 0030-493X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The mass spectra of twenty-eight N-substituted 2-aminobenzoxazoles and 2-aminobenzothiazoles have been recorded and the identity of various ions in the mass spectra have been established by high resolution measurement. The molecular compound of series, benzoxazole, undergoes loss of hydrogen cyanide and carbon monoxide from the molecular ion as the most important decomposition pathways. The mass spectra of N-substituted benzothiazoles showed a similar fragmentation as that of N-substituted benzoxazoles.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...