Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    European journal of applied physiology 71 (1995), S. 559-561 
    ISSN: 1439-6327
    Keywords: Critical power ; Anaerobic work capacity ; Methodology ; Electrically-braked ergometer
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract This study examined the effect of end-point cadence on the parameters of the work-time relationship determined for cycle ergometry. Eight male subjects completed four maximal tests on an electrically-braked cycle ergometer that regulated a constant power output independent of cadence. The power outputs imposed ranged between an average of 259 W and 403 W, whereas the corresponding durations ranged between 139 s and 1691 s. During each test subjects were required to maintain a cadence of 80–90 rpm. Accumulated time to end-point cadences of 70, 60 and 50 rpm were recorded. The four work-time determinations for each of three end-point cadences were used to determine linear relationships between work and time, yielding both a y-intercept, which represents anaerobic work capacity, and a slope, which is termed critical power (CP), for each end-point cadence. There was a significant increase in the y-intercept as end-point cadence decreased from 70 to 60 rpm (F[1,7]=36.7, p 〈 0.001) or 70 to 50 rpm (F[1,7]=80.1, p 〈 0.001), but not from 60 rpm to 50 rpm (F[1,7]=3.28, p 〉 0.05). In contrast, there was no effect of end-point cadence on CP (F[2,14]=1.89, p 〈 0.05). These results demonstrate that the end-point cadence selected to terminate tests only affects the y-intercept of the work-time relationship. To control for this effect, the cadence at which each test is terminated should be standardised if determination of anaerobic work capacity, as represented by the y-intercept, is required.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1955
    Keywords: In vitro culture ; Anthelmintics ; Primary screening test ; Nippostrongylus brasiliensis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Abstract A new in vitro test suitable for the large scale screening of chemical compounds for anthelmintic activity is described. The test which utilizes the fourth larval and adult stages ofNippostrongylus brasiliensis in a medium capable of supporting the growth and development of the parasite, detects selectively those compounds which possess either broad spectrum anthelmintic or specific anti-trichostrongyle activity. The screen is easy to operate requiring only minute quantities of experimental compound. It renders fully reproducible results which furthermore can be interpreted objectively. This is the first reported in vitro test directed against the parasitic stages of a nematode that is capable of detecting reliably the activity of a wide range of anthelmintics including thiophanate and all the benzimidazoles.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...