    Trauma und Berufskrankheit 1 (1999), S. 182-186 
    ISSN: 1436-6274
    Keywords: Schlüsselwörter NITINOL-Klammern ; Kahnbein ; Kompressionsosteosynthese ; Key words Nitinol staple ; Scaphoid ; Compression osteosynthesis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: The thermoplastic nickel–titanium alloy Nitinol has excellent shape memory when transferred from deep-freeze temperatures to body temperature or even 45°C, which means that staples made of this material for use in internal fixation exert a lasting compressive effect after implantation. From October 1995 to January 1998 we performed 22 compression osteosynthesis operations on scaphoid bones. The indications were: dislocated fracture in 10 cases, in 6 of them with Quervain’s luxation fracture, and pseudarthroses in 12. In 10 osteosynthesis operations we used drilling wires in addition, for internal direction of the compressing force of the staples. After osteosynthesis 21 of the 22 scaphoids healed. Three clamps were removed after the bone had healed. One staple broke with the bone in an accident. Our first impressions suggest that thermoplastic Nitinol staples are ideal for compression osteosynthesis of the scaphoid bone for the treatment of displaced fractures or pseudarthroses in the middle third. Their use offers advantages over osteosynthesis with screws. Because our experience with these staples was so good we shortened the period of immobilization from 12 to 6 weeks.
    Notes: Die sog. “Formgedächtnis”-Eigenschaft der Nickel-Titan-Legierung NITINOL beim Wechsel von der Tiefkühlung zur Körperwärme bzw. 45°C gibt Klammern, die aus diesem Material und zu diesem Zweck gefertigt wurden, nach der Implantation eine dauerhaft komprimierende Wirkung. Von Oktober 1995 bis Januar 1998 führten wir 22 Osteosynthesen an Kahnbeinen durch. Die Indikationen waren: 10mal verschobene Brüche, davon 6 bei De-Quervain-Luxationsfraktur, und 12mal Falschgelenke. Bei 10 Osteosynthesen benutzten wir zusätzlich Kirschner-Drähte zur inneren Führung der komprimierenden Kraft der Klammer. 21 von 22 Osteosynthesen führten zur Heilung. 3 Klammern wurden nach der Knochenheilung entfernt. Eine Klammer brach mit dem Knochen nach einem geeigneten Trauma. Es kam zu keiner Infektion. Klammern aus NITINOL scheinen sich nach unseren ersten Erfahrungen zur Kompressionsosteosynthese an Kahnbeinen wegen verschobener Brüche und wegen Falschgelenken im mittleren Drittel zu eignen. Ihre Anwendung hat Vorteile gegenüber der Osteosynthese mit Schrauben. Aufgrund der guten Erfahrungen kürzten wir die Zeit der Ruhigstellung von 12 auf 6 Wochen.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Langenbeck's archives of surgery 372 (1987), S. 939-939 
    ISSN: 1435-2451
    Keywords: Revascularization ; Muscle graft ; Blood vessel ; Implantation ; Revascularisierung ; Muskeltransplantat ; Implantation von Blutgefässen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Die Implantation der A. und V. femoralis in frei transplantierte, isolierte, mediale Köpfe des M. gastrocnemius führte bei Ratten zur Revascularisierung der Muskulatur. Nach 4 Tagen waren in den gefässnahen Regionen des Muskels kleinkalibrige Gefässe anzutreffen, nach 3 Wochen war der Muskel bis zur bindegewebigen Kapsel unterhalb der Gore-Tex Surgical Membrane-Ummantelung perfundiert. Der Revascularisierung ging eine Invasion motiler Zellen voraus, die fischzugähnlich das Muskeltransplantat besetzten. Die Gefässsprosse entstammten vorwiegend der V. femoralis, Narbenbildung im Transplantat konnte nach 4 Wochen nicht beobachtet werden.
    Notes: Summary Implantation of the femoral artery and vein into the free-transplanted, isolated, medial capita of the gastrocnemius muscle in rats led to revascularization of this part of the muscle. After 4 days, in the muscle part lying near the implanted vessels, small vessels were seen that came from the femoralis vein. After 3 weeks, the whole free graft was revascularized up to the surrounding tissue beneath the Gore-Tex surgical membrane. An invasion of motile cells preceded the revascularization; the cells occupied the peri- and endomysium of the graft. After 4 weeks no muscle scars could be observed in the transplant.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Langenbeck's archives of surgery 358 (1982), S. 484-484 
    ISSN: 1435-2451
    Keywords: External fixation ; Open fractures ; Soft-tissue damage ; Osteitis ; Fixateur externe ; offene Frakturen ; Weichteilschaden ; Osteitis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung An der Chirurgischen Universitätsklinik Basel wurden von 1970-1981 88 Stabilisierungen mit dem Fixateur externe durchgeführt. Das sind weniger als 2 % der sonst durchgeführten internen Osteosynthesen am Fernur und der Tibia. 56mal wurde der Fixateur externe zur Primärversorgung einer Fraktur eingesetzt. 32mal erfolgte die externe Fixation bei nach anderen Methoden infizierten Frakturen. Indikation, Technik, postoperativer Verlauf sowie die Nachuntersuchungsergebnisse werden dargestellt.
    Notes: Summary Between 1970 and 1981 external fixation was used in 86 patients with a total of 88 fractures. In 56 cases primary external fixation was indicated by severe injuries of the extremity. If internal fixation or conservative treatment failed, secondary external fixation was used (32 cases). In 50 %, the stability of primary external fixation was increased by means of additional lag-screw fixation. In 50 % we later changed to internal fixation, partly due to healing of the soft tissue, partly to delayed cortical bone healing. Severe osteitis was observed after primary fixation in 21 % of the cases. After an average of 31 weeks in primary and 49 weeks in secondary cases full weight-bearing was possible. Final results at follow-up are reported.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Langenbeck's archives of surgery 352 (1980), S. 516-516 
    ISSN: 1435-2451
    Keywords: Kidney transplantation ; Transfusion ; Antibodies ; Nierentransplantation ; Bluttransfusion ; Antikörper
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Vom 1.1.1977–31.12.1979 wurden 72 Nierentransplantationen durchgeführt. Alle Empfänger hatten nach einem Schema Bluttransfusionen erhalten. Nachuntersucht wurde das Auftreten lymphocytotoxischer Antikörper, die Wartezeit und die Transplantatfunktion. Bei 65 % der Patienten traten nie Antikörper auf. 72% der Transplantate überlebten 1 Jahr; 69% 2 Jahre. Die durch unser Transfusionsprogramm verbesserten Resultate kamen nicht durch eine transfusionsbedingte Selektion zustande, da die wenigen Reaktoren zwar länger warteten, alle aber doch noch ein Transplantat bekamen.
    Notes: Summary From January 1977 through December 1979, 72 kidney transplantations were made. All recipients received transfusions according to a special plan. The development of lymphocytotoxic antibodies, the waiting time, and the function of the transplant were checked. Of the total patients, 65% never developed antibodies. After one year, the survival rate of the transplants was 72%; after two years, survival was 69%. The better results after our transfusion program were not achieved by selection. A few high responders had to wait longer, but all of them finally received a transplant.