    ISSN: 1572-8595
    Keywords: Radiofrequency Energy ; PSVT ; Catheter Ablation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Temperature monitoring may be helpful for ablation of accessory pathways, however its role in ablation of atrioventricular nodal reentrant tachycardia (AVNRT) using the slow pathway approach is unclear. Therefore, the purpose of this study was to prospectively compare slow pathway ablation for AVNRT using fixed power or temperature monitoring. The study included 120 patients undergoing ablation for AVNRT. Patients were randomly assigned to receive either fixed power at 32 watts, or to temperature monitoring with a target temperature of 60°C. The primary success rate was 72% in the fixed power group and 95% in the temperature monitoring group (p=0.001). The ablation procedure duration (35±29 min vs 35±30 min; p=0.9), fluoroscopic time (32±17 vs 35±19 min; p=0.4), mean number of applications (10.2±8.1 vs 8.4±7.9; p=0.2), and coagulum formation per application (0.2% vs 0.5%; p=0.6) were statistically similar in the fixed power and temperature monitoring groups, respectively. The mean temperature (47.3±4.8°C vs 48.6±3.8°C; p〈0.01), and the temperature associated with junctional ectopy (48.2±3.8°C vs 49.3±3.6°C, p〈0.01) were less for the fixed power than the temperature monitoring group. In the temperature monitoring group, only 31% of applications achieved an electrode temperature of 60°C. During follow up of 6.6±3.6 months there were two recurrences in the fixed power group and one in the temperature monitoring group (p=1.0). In summary, power titration directed by temperature monitoring was associated with an improved primary procedural success rate. Applications of energy were associated with a temperature of approximately 50°C with both techniques, suggesting that there is a low efficiency of heating in the posterior septum.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Experimental brain research 41 (1981), S. 115-120 
    ISSN: 1432-1106
    Keywords: Imprinting ; Synapse ; Hemispheric asymmetry ; Domestic chicks
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Fourteen chicks were hatched and reared in darkness to ≅ 21 h when they were exposed to overhead illumination for 0.5 h and then to an imprinting stimulus (a pulsing red light) for 20 min. The chicks were then matched in pairs on the basis of their activity. One member of each pair was returned to the dark and the other was trained for a further 120 min. All chicks were killed ≅ 6.5 h after the onset of training and perfused with fixative. Blocks were removed bilaterally from a restricted part of the hyperstriatum ventrale and prepared for electronmicroscopy. Various synaptic features were measured, all counts being performed ‘blind’. In undertrained chicks the length of the synaptic apposition zone in this part of the left hemisphere was shorter than that in the right by a mean value of 35±11.4 (SEM) nm. Further training eliminated this difference. No other synaptic measurements were affected by prolonging the period of training.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Pediatric cardiology 2 (1982), S. 245-250 
    ISSN: 1432-1971
    Keywords: Hypercarbia ; Infancy ; Congenital heart disease
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Three infants are described who illustrate 3 distinct mechanisms by which cardiac disease may cause carbon dioxide retention: 1) hypoventilation 2) large alveolar dead space and 3) decreased effective pulmonary blood flow. These mechanisms are illustrated here in patients with problems commonly encountered in the infant with symptomatic congenital heart disease. The physiologic basis of their carbon dioxide retention is also discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Statistics and computing 1 (1991), S. 119-128 
    ISSN: 1573-1375
    Keywords: Bayesian inference ; Gibbs sampler ; hierarchical models ; logistic regression ; nonlinear models ; rejection method
    Source: Springer Online Journal Archives 1860-2000
    Topics: Computer Science , Mathematics
    Notes: Abstract The Gibbs sampler has been proposed as a general method for Bayesian calculation in Gelfand and Smith (1990). However, the predominance of experience to date resides in applications assuming conjugacy where implementation is reasonably straightforward. This paper describes a tailored approximate rejection method approach for implementation of the Gibbs sampler when nonconjugate structure is present. Several challenging applications are presented for illustration.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...