Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1920
    Keywords: Key words Neurofibromatosis ; Vertebral arteriovenous fistula ; Doppler sonography ; Hemodynamics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract A Doppler sonographic guidewire was used to monitor incremental changes in draining vein (DV) flow during endovascular occlusion of a complex vertebral arteriovenous fistula (AVF) in a patient with neurofibromatosis type 1. Transvenous monitoring of average peak velocity (APV) and the maximum-minus-minimum peak velocity (MxPV-MnPV) demonstrated a progression from a highly pulsatile, fast flow before embolization to a nonpulsatile, slow flow indicating a successful occlusion of the AVF (hemodynamic endpoint of treatment). Prior to this, apparent angiographic occlusion of the AVF was thought to signify a successful endpoint; however, persistently elevated values for APV and MxPV-MnPV in the DV signalled the presence of an additional contralateral arterial contribution. Transvenous monitoring of flow velocity appears to be ideally suited to establishing a hemodynamic endpoint of embolotherapy in the presence of complex arteriovenous shunting, as may occur with the vasculopathy of neurofibromatosis.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 293 (1978), S. 104-106 
    ISSN: 1618-2650
    Keywords: Best. von Thorium(IV) ; Polarographie ; Substitutionsreduktion des Bi(III)-ÄDTE-Chelats, Tastpolarographie
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary Thorium(IV) facilitates the reduction of bismuth(III)-ethylenediaminetetraacetate chelate in weakly acidic medium and gives a new wave at a more positive potential, because the EDTA anion liberated by the reduction will be caught immediately by thorium(IV) ion. The height of the substitution reduction wave is proportional to the concentration of thorium(IV) between 0.1 and 0.6 mM. Properties of the wave and the electrode process were investigated.
    Notes: Zusammenfassung Thorium(IV) erleichtert die Reduktion des Wismut(III)-ÄDTE-Chelats in schwach sauerem Medium und gibt eine neue Welle bei positiverem Potential, da das durch die Reduktion freigesetzte ÄDTE-Anion vom Thorium(IV)-Ion sofort ergriffen wird. Die Höhe der Substitutionsreduktionswelle ist zwischen 0,1 und 0,6 mM der Thorium(IV)-Konzentration proportional. Eigenschaften der Welle und der Elektrodenvorgang wurden untersucht.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...