Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1433-0407
    Keywords: Schlüsselwörter Koenzym Q ; Fahrradbelastungstest ; Laktat ; Laktat/Pyruvat-Quotient ; Mitochondriale Myopathien ; Key words Coenzyme Q ; Bicycle ergometry ; Lactate ; Lactate/pyruvate-ratio ; Mitochondrial myopathies
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary
    Notes: Zusammenfassung
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1459
    Keywords: Human β-endorphin ; Cerebrospinal fluid ; Simplified RIA-determination
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Beta-human-Endorphin-like immunreaktive Substanzen (β h -EI) im menschlichen Liquor (CSF) wurden radioimmunologisch bestimmt. Die Kreuzreaktivität des von uns eingesetzten Antikörpers gegen Beta-human-Endorphin (β h -E) zum Beta-human-Lipoprotein (β h -LPH) betrug 40%, während sie zu Leu- und Met-Enkephalin, Alpha- und Gamma-Endorphin, Fraktion I und II nach Terenius [10], Substanz P und Alpha-MSH geringer war als 1%. Vor der radioimmunologischen Bestimmung wurde eine Adsorption von β h -EI aus CSF an Kieselsäure mit anschließender Desorption mittels eines Gemisches aus Aceton/Salzsäure durchgeführt. Diese Methode wurde gewählt, weil sich dadurch das Verhältnis von β h -LPH zu β h -E im Desorbat zugunsten von β h -E aufgrund der unterschiedlichen Recoveries R ( $$R_{\beta _h - LPH} $$ =33%, $$R_{\beta _h - E} $$ =66%) verschob. Damit wird einerseits eine erhöhte Spezifität bei der Bestimmung von β h -EI und andererseits eine Abtrennung von eventuell vorhandenen Peptidasen erreicht. Eine Adsorption/Desorption aus 2 ml CSF genügt, um β h -EI von 20–150 pg/ml (6–48 fmol/ml) nachzuweisen. Patienten (n=28) mit verschiedenen neurologischen Erkrankungen wiesen Werte von 20–70 pg/ml auf. Vier Liquores unter 20 pg/ml stammten von Meningitis-Patienten, welche unter einer Corticoidtherapie standen. Ein käuflicher RIA-Kit wurde auf seine Eignung zur Bestimmung von β h -E untersucht und verworfen.
    Notes: Summary Human β-endorphin-like immunoreactive substances (β h -EI) in human cerebrospinal fluid (CSF) were determined radioimmunologically. The cross reactivity of the antibodies to human β-endorphin (β h -E) amounted to 40% for human β-lipotropin (β h -LPH) whilst it was less than 1% for leu-and metenkephalin, α- and γ-endorphin, fraction I and II [5], substance P and α-MSH. Prior to radioimmunological determination, an adsorbtion of β h -EI from CSF with silicic acid was carried out and followed by a desorbtion, using a mixture of aceton/hydrochloric acid. This method was chosen because the ratio of β h -LPH to β h -E in the desorbat can be shifted in favour of β h -E owing to the variation in recoveries r ( $$r_{\beta _h - LPH} $$ =33%, $$r_{\beta _h - E} $$ =64%). On the one hand, this enables a more specific determination of β h -E and, on the other hand, and separation of any peptidase than may be present [9]. An adsorbtion/desorbtion of 2 ml CSF suffices to prove the presence of 20–150 pg/ml (6–48 fmol/ml) of β h -EI. The CSF of 28 patients with various neurological diseases was examined and 24 of them had concentrations of 20–70 pg/ml β h -EI. The remaining four, which had concentrations less than 20 pg/ml, came from meningitis patients undergoing corticoid therapy. A purchasable RIA kit was tested for its determination of β h -E and was found to be unsuitable.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...