Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1920
    Keywords: Key words Magnetic resonance imaging ; Optic neuritis ; Multiple sclerosis ; Visual evoked potentials
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract MRI of the optic nerves was obtained in 13 patients with acute optic neuritis and 13 with a previous optic neuritis (ON), assessed by clinical features, visual fields and visual evoked potentials. Results of the conventional short tau inversion recovery (STIR) sequence obtained with a short echo time (STE-STIR; 22 ms) were compared with those of a long echo time (LTE-STIR: 80 ms) sequence. The conventional STE-STIR sequence revealed lesions in the optic nerves in 78.5 % of acute and 58.8 % of previous ON. The LTE-STIR sequence showed abnormalities in 92.8 % of acutely symptomatic nerves and 94.1 % of nerves with previous ON. The optic nerve lesions appeared significantly longer with the LTE-STIR sequence than with the conventional STE-STIR sequences, in both acute and previous ON.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1920
    Keywords: Magnetic resonance imaging ; Optic neuritis ; Multiple sclerosis ; Visual evoked potentials
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract MRI of the optic nerves was obtained in 13 patients with acute optic neuritis and 13 with a previous optic neuritis (ON), assessed by clinical features, visual fields and visual evoked potentials. Results of the conventional short tau inversion recovery (STIR) sequence obtained with a short echo time (STE-STIR; 22 ms) were compared with those of a long echo time (LTE-STIR: 80 ms) sequence. The conventional STE-STIR sequence revealed lesions in the optic nerves in 78.5% of acute and 58.8% of previous ON. The LTE-STIR sequence showed abnormalities in 92.8% of acutely symptomatic nerves and 94.1% of nerves with previous ON. The optic nerve lesions appeared significantly longer with the LTE-STIR sequence than with the conventional STE-STIR sequences, in both acute and previous ON.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1590-3478
    Keywords: Visual evoked potentials ; VEP ; Optic neuritis ; Multiple sclerosis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Sommario I 20 pazienti affetti da Neurite Ottica (NO), descritti nel precedente lavoro [23] sono stati sottoposti a registrazioni seriali multicanali dei Potenziali Evocati Visivi (PEV), per un periodo di 2 anni dall'esordio della NO. I PEV potevano correlare con le lesioni evidenziate con la Risonanza Magnetica, con le alterazioni campimetriche e con altri reperti clinici. Basandoci sulla loro distribuzione in mappa, i PEV sono stati classificati come realmente “ritardati” e “pseudo-ritardati”. PEV realmente “ritardati” potevano essere registrati all'esordio, o precocemente dopo l'episodio di NO, e la presenza del “ritardo” stava ad indicare un recupero della funzione visiva e, quindi, una prognosi fausta. Gli “pseudo-ritardi” indicavano un'alterazione del campo visivo a prognosi non favorevole per un recupero della funzione visiva, a meno che entro i primi 3 mesi dalla NO si fosse verificata una ricomparsa di componenti normali o “ritardate”. Gli “pseudo-ritardi” erano rilievi caratteristici nei pazienti con lesioni maggiormente lunghe alle immagini LTE-STIR MRI [23]. Nessuna correlazione è stata trovata tra latenza dei PEV e lunghezza delle placche. I nostri rilievi sono in disaccordo con precedenti teorie relative ai tempi di instaurazione-recupero delle alterazioni di conduzione nella NO e nella Sclerosi Multipla.
    Notes: Abstract Twenty patients with optic neuritis (ON) described in the previous study [23] underwent serial VEP recordings (using multiple electrode arrays) for two years. The VEPs could be correlated with the lesions revealed by MRI, Visual Field tests and other clinical findings. On the basis of their scalp distribution, they were classified as “really delayed” VEPs and “pseudo-delayed” VEPs. Real delays could be recorded at the onset of ON or shortly afterwards, and their appearance indicated the recovery of visual function and a good prognosis. Pseudo-delays indicated an alteration in the visual field and, unless a breakthrough of normal or delayed components appeared in the first three months, following acute ON, indicate a poor prognosis for the recovery of visual function. The pseudo-delayed VEPs were mainly observed in patients with longer lesions revealed by means of LTE-STIR MRI [23]; there was no correlation between VEP latency and the length of plaques. Our findings contradict previous theories on the timing of conduction alterations in ON and multiple sclerosis.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1590-3478
    Keywords: MRI ; Optic neuritis ; Multiple sclerosis ; VEP
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Sommario Si descrivono i risultati ottenuti con indagini di Risonanza Magnetica (RM) dei nervi ottici (eseguite all'esordio e 12 mesi dopo) in 20 pazienti affetti da Neurite Ottica (NO) acuta, valutata in funzione della sintomatologia clinica e delle alterazioni campimetriche e del potenziale evocato visivo. Sono state analizzate le immagini RM in Short Tau Inversion Recovery (STIR) mettendo a confronto i rilievi ottenuti con sequenza Short Time Echo (STE-STIR: 22 msec) rispetto a quelli ottenuti con Long Time Echo (LTE-STIR: 20 msec). Mentre con la convenzionale STE-STIR è stato possibile rilevare lesioni a carico dei nervi ottici nel 57.2% delle Neuriti Acute e nel 42.9% delle Neuriti Pregresse, la metodica LTE-STIR è risultata diagnostica nel 95.2% delle Neuriti Acute e nel 85% delle Neuriti Pregresse. Sia nelle NO acute che nelle pregresse, la lunghezza delle lesioni a carico dei nervi ottici sono risultate significativamente maggiori rispetto a quelle ottenute con la convenzionale metodica STE-STIR.
    Notes: Abstract Magnetic resonance images of optic nerves were obtained in 20 patients with acute optic neuritis (ON), and assessed by means of clinical, visual field and visual evoked potential evaluations; the imaging was repeated 1 year later. The results of the conventional Short Tau Inversion Recovery (STIR) sequence obtained using short time echo (STE-STIR: 22 msec) were compared with those of the long time echo sequence (LTE-STIR: 80 msec). The conventional STE-STIR sequence revealed lesions in 57.2% cases of acute ON and in 42.9% of the optic nerves affected by previous ON: the LTE-STIR sequence was diagnostic in 95.2% of acute ON cases and in 85% of patients with previous ON. The calculated length of the optic nerve lesions was significantly longer in the images obtained using the LTE-STIR sequence than in those obtained using conventional STE-STIR sequences.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Proteins: Structure, Function, and Genetics 8 (1990), S. 334-340 
    ISSN: 0887-3585
    Keywords: protein structure ; structural comparison ; α-β barrels ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: By exhaustive structural comparisons, we have found that about one-third of the α-helix-turn-β-strand polypeptides in α-β barrel domains share a common structural motif. The chief characteristics of this motif are that first, the geometry of the turn between the α-helix and the β-strand is somewhat constrained, and second, the β-strand contains a hydrophobic patch that fits into a hydrophobic pocket on the α-helix. The geometry of the turn does not seem to be a major determinant of the α-β unit, because the turns vary in length from four to six residues. However, the motif does not occur when there are few constraints on the geometry of the turn-for instance, when the turns between the α-helix and the β-strands are very long. It also occurs much less frequently in flat-sheet α-β proteins, where the topology is much less regular and the amount of twist on the sheet varies considerably more than in the barrel proteins. The motif may be one of the basic building blocks from which α-β barrels are constructed.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 0952-3499
    Keywords: Cytokine ; Receptor ; Biosensor ; Titration ; Calorimetry ; Association rate ; Dissociation rate ; Equilibrium analysis ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: A surface plasmon resonance (SPR) biosensor was used to study the interaction of human interleukin-5 (hIL5) with its receptor. IL5 is a major growth factor in the production and activation of eosinophilis. The receptor for IL5 is composed of two subunits, α and β. The α subunit provides the specificity for IL5 and consist of an extracellular soluble domain, a single transmembrane region and a cytoplasmic tail. We expressed the soluble domain of the human IL5 receptor α subunit (shIL5Rα) and human IL5 (hIL5) in Drosophila. Both hIL5 and shIL5Rα were immobilized separately through amine groups onto the carboxylated dextran layer of sensor chips of the BIAcore™ (Pharmacia) SPR biosensor after N-hydroxysuccinimide/carbodiimide activation of the chip surface. Interactions were measured for the complementary macromolecule, either shIL5Rα or hIL5, in solution. Kinetics of binding of soluble analyst to immobilized ligand were measured and from this the association rate constant, dissociation rate constant and equilibrium dissociation constant (Kd) were derived. With immobilized shIL5Rα and soluble hIL5, the measured Kd was 2 nM. A similar value was obtained by titration calorimetry. The Kd for Drosophila expressed receptor and IL5 is higher than the values reported for proteins expressed in different systems, likely due to differences in the methods of interaction analysis used for differences in protein glycosylation. Receptor-IL5 binding was relatively pH independent between pH 6.5 and 9.5. Outside this range the dissociation rate increased with compressibility little increased in association rate. The values obtained for the interaction of hIL5 and shIL5Rα were found to depend on which component was immobilized; the Kd was 5.5 nM with immobilized hIL5 and soluble shIL5Rα. The SPR biosensor provides a unified methodology to measure the interaction properties of shIL5Rα and hIL5 derivatives, mutants and mimetic as well as to evaluate potential antagonists of the receptor-cytokine interaction.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Electrophoresis 17 (1996), S. 1075-1079 
    ISSN: 0173-0835
    Keywords: Pulsed-field electrophoresis ; Microlithographic array ; Fractionation ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: Transverse pulsed-field electrophoresis of DNA has been conducted in a silicon array engineered by optical lithography and the motion of individual molecules observed by fluorescence microscopy. In strong fields, the molecules can be maintained in highly stretched, linear conformations. When the field is switched through an obtuse angle, they head off in the new direction led by what was formerly their tail end. This backtracking gives rise to fractionation that is linear with molecular weight. A simple prescription exists for choosing the field parameters to obtain a particular range of separation. Since the molecular motions are much more uniform than those that occur in a gel, it is anticipated that the arrays will permit more efficient fractionation than traditional pulsed-field gel electrophoresis. Arrays suitably scaled down in size may be useful for pulsed-field sequencing.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 0173-0835
    Keywords: Multiplex polymerase chain reaction ; Tailed primers ; Gene mapping ; Short tandem repeat polymorphisms ; ODS ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: Short tandem repeat polymorphism (STRP) markers have become important reagents for mapping genetic diseases. These markers are available as screening sets, which are located in all chromosomes at discrete intervals, allowing the entire genome to be analyzed. Mapping studies that include many individuals in the analysis necessitate the production of large numbers of genotypes. In an effort to increase the efficiency and lower the cost of using these STRP screening sets, we have divided the amplification primers of the Weber 8A screening set into groups that can be amplified in single polymerase chain reaction (PCR) amplification reactions, resulting in a reduction of both time and cost. Fluorescently-labeled amplification products were produced using a three primer reaction. The forward STRP amplification primer for each marker contained a 19 bp sequence at the 5′ end. A fluorescently-labeled primer, with a sequence identical to the 19 bp tail, was added to the amplification reaction as the sole source of fluorescent label. The STRP banding pattern is detected using an automated fluorescent DNA sequencer. Use of this multiplexed genomic screening set should greatly enhance the mapping of human disease loci.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Biochemical and Microbiological Technology and Engineering 2 (1960), S. 339-359 
    ISSN: 0368-1467
    Keywords: Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Engineering data on the design and operation of algal culture systems for photosynthetic gas exchange are virtually non-existent. The authors have conducted intermediate and definitive level engineering studies to characterize algal systems - with a view to extrapolating to larger-scale systems for life support in closed spaces.Light intensity, carbon dioxide concentration, and dilution rate were the principal parameters used to control the photosynthetic rate and, consequently, oxygen production. Carbon dioxide absorption rate, equilibrium density, and cellular growth rate were also investigated.It was found that: (1) properly jacketed high intensity, incandescent lamps provided a suitable light source for growing algae; and (2) physiologically safe (0·5 per cent) concentrations of carbon dioxide produced growth comparable to that obtained at higher concentrations.A dilution rate of nearly 0·1 volume change per hour produced the best oxygen yield (2·41 × 10-3 lb/h) for the definitive system. Maximum cell doubling time was 5·1 h. The highest culture density attained was 5·9 mm3/ml, and the maximum dry weight algae yield was 3·0 × 10-3 lb/h.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...