Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-2277
    Keywords: Heart transplantation, endomyocardial biopsy ; Biopsy, endomyocardial ; Endomyocardial biopsy, heart transplantation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Since 1989, the immunosuppressive regimen used in all heart transplant (HTx) patients at our center has consisted of a combination of cyclosporin, azathioprine, and prednisone. No prophylactic cytolytic agents have been given. One hundred consecutive patients were followed for periods of 4–56 months (mean 27 months). The incidence of rejection was so low in the initial 18 patients that we felt confident about reducing the number of routine endomyocardial biopsies (EMBs) that were performed. The mean number of EMBs in this subgroup was 10 (median 11). In the next 20 patients, EMB was performed routinely on only three occasions during the 1st post-transplant year (at 2, 4, and 8 weeks). In the subsequent 62 patients, EMB was performed on post-transplant days 10, 20, 30, and 60. Further EMBs were performed after acute rejection episodes had been treated. No noninvasive methods of diagnosing rejection were employed. In 82 consecutive patients, therefore, the mean number of EMBs within the 1st year was five per patient (median four), with 58% undergoing fewer than five EMBs and 25% requiring more than five EMBs. In the entire group of 100 patients, the mean number of EMBs was 5.9. The incidence of acute rejection requiring increased therapy was 24%. Only 7% required i.v. steroids, two of whom (2%) also required ALG and/or OKT3, with 17% requiring increased oral immunosuppression alone. Actuarial survival was 98% at 30 days, 94% at 1 year, and 92% at 2 years. It is possible that we may have missed acute rejection episodes that resolved spontaneously. However, the excellent mediumterm results would suggest that any such rejection episode did not progress to become hemodynamically significant. It may be, therefore, that when an effective immunosuppressive regimen is utilized, the number of EMBs performed at many centers is excessive.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 31 (1985), S. 1202-1212 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Significant noise (random error) is common in an on-line signal when measuring the particle size distribution in a fluidized bed. The application of optimal estimation theory to obtain a filtering algorithm that can rectify such measurements is detailed. Off-line simulation studies demonstrate that the filtering algorithm yields a measure of particle size distribution that is well-behaved, accurate, and able to track in real time as conditions change in the bed.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 32 (1986), S. 186-194 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Optimal distributed-parameter filters are commonly implemented using approximating lumped Kalman filtering theory. The effect of such an approximation is investigated. A theoretical development shows that there is a loss in the spatial noise correlation for the lumped approximants. Two numerical examples of engineering significance illustrate that one result of this loss is slower filter convergence for the lumped approximants relative to the full distributed-parameter filters.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 32 (1986), S. 389-396 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: A novel method for tracking particle size distribution dynamics in a fluidized bed yields on-line, real-time measurements of particle size distribution that are representative of actual conditions. These measurements are somewhat corrupted with noise (random error), however, and are available to the computer only at discrete time intervals. An optimal filtering algorithm combines the measurements with predictions from an idealized dynamic model to yield particle size distribution estimates that are not only on-line and real-time, but also virtually continuous and well-behaved.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗