Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1920
    Keywords: Key words Computed tomography ; head and neck ; Contrast medium ; dose ; Comparative study
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Adequate contrast enhancement of major neck vessels is more important than that of a tumour itself in CT of most head and neck tumours because of differentiation from neck node metastases. Our purpose was to re-evaluate the dosage of contrast medium for adequate vascular enhancement in CT of the head and neck. In a blind prospective fashion, 60 patients with a variety of head and neck lesions were randomised into three equal groups receiving 0.75, 1.0, or 1.25 ml/kg of meglumine ioglycate, 300 mg/ml. Contrast medium was administered by injector at 2 ml/s. The scan time and interscan delay were each 1 s, and total scan time 50–180 s. The scan was started immediately after administration of two-thirds of the contrast medium. The degree of vascular enhancement was assessed visually and quantitatively. We visually scored the degree of vascular enhancement as excellent (4 points), good (3), fair (2) or poor (1). For quantitative study, after measuring the CT numbers of the common or internal carotid artery (CA), internal jugular vein (IJV) and adjacent muscle at three levels, were calculated mean vessel/muscle contrast ratios. The degree of enhancement of the CA and IJV tended to increase with dose of the contrast media, but no examination was rated as showing poor enhancement in any group. The mean visual assessment scores for 0.75, 1.0, and 1.25 ml/kg were 2.7, 2.9 and 3.1, respectively; the mean ICA/muscle contrast ratios were 1.58, 1.55 and 1.63, and those of IJV/muscle 1.65, 1.59 and 1.59. There was no significant difference between visual and quantitative assessment in any group. The results suggest that 0.75 ml/kg of contrast medium appears sufficient for vascular opacification for head and neck lesions when the CT scan can be completed in about 120 s.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1920
    Keywords: Key words Magnetic resonance imaging, diffusion-weighted ; Brain abscess ; Brain tumour ; Cysticercosis ; Radiation necrosis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Our purpose was to investigate the signal intensities of cystic or necrotic intracranial lesions on diffusion-weighted MRI (DWI) and measure their apparent diffusion coefficients (ADC). We examined 39 cystic or necrotic intracranial lesions in 33 consecutive patients: five malignant gliomas, seven metastases, two other necrotic tumours, a haemangioblastoma, three epidermoids, an arachnoid cyst, seven pyogenic abscesses, 12 cases of cysticercosis and one of radiation necrosis. DWI was performed on a 1.5 T unit using a single-shot echo-planar spin-echo pulse sequence with b 1000 s/mm2. The signal intensity of the cystic or necrotic portion on DWI was classified by visual assessment as markedly low (as low as cerebrospinal fluid), slightly lower than, isointense with, and slightly or markedly higher than normal brain parenchyma. ADC were calculated in 31 lesions using a linear estimation method with measurements from b of 0 and 1000 s/mm2. The cystic or necrotic portions of all neoplasms (other than two metastases) gave slightly or markedly low signal, with ADC of more than 2.60 × 10−3 mm2/s. Two metastases in two patients showed marked high signal, with ADC of 0.50 × 10−3 mm2/s and 1.23 × 10−3 mm2/s, respectively. Epidermoids showed slight or marked high signal, with ADC of less than 1.03 × 10−3 mm2/s. The arachnoid cyst gave markedly low signal, with ADC of 3.00 × 10−3 mm2/s. All abscesses showed marked high signal, with ADC below 0.95 × 10−3 mm2/s. The cases of cysticercosis showed variable signal intensity; markedly low in five, slightly low in three and markedly high in four.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...