Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Intensive care medicine 24 (1998), S. 635-638 
    ISSN: 1432-1238
    Keywords: Key words Reperfusion damage ; Complement system ; Cardiac surgery ; Postoperative heart failure ; C1-esterase inhibitor
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Administration of C1-esterase inhibitor (C1-INH) attenuates myocardial necrosis and sustains normal cardiac performance after myocardial ischemia and reperfusion in animal experiments. We report on our first experience of C1-INH application as rescue therapy in patients undergoing emergency surgical revascularization after failed percutaneous transluminal coronary angioplasty. Three patients were treated, because postoperative hemodynamic stabilization could not be achieved despite prolonged reperfusion periods, high-dose inotropic support, inodilators and aortic counterpulsation. As there was no surgical or medical option remaining, C1-INH was administered starting with a 2000 unit bolus, followed by 1000 U 12 and 24 h after surgery. C1-INH therapy resulted in rapid hemodynamic stabilization of all patients; weaning from aortic counterpulsation and epinephrine support was possible within 1 day. All patients survived and were discharged from hospital. In this group of patients suffering from severe reperfusion injury after coronary surgery, C1-INH seemed to be an effective adjuvant therapy to restore myocardial function by blocking the complement cascade. These results should encourage the performance of controlled studies on the effects of prophylactic C1-INH substitution therapy in patients undergoing coronary surgery at high risk conditions.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1238
    Keywords: Key words Weaning ; CPAP ; BiPAP ; Extravascular lung water ; Cardiac surgery
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Objective: To evaluate the effects of continuous positive airway pressure (CPAP) and bi-level positive airway pressure (BiPAP) on extravascular lung water during weaning from mechanical ventilation in patients following coronary artery bypass grafting. Design; Prospective, randomized clinical study. Setting; Intensive care unit at a university hospital. Patients; Seventy-five patients following coronary artery bypass grafting. Interventions; After extubation of the trachea, patients were treated for 30 min with CPAP via face mask (n=25), with nasal BiPAP (n=25), or with oxygen administration via nasal cannula combined with routine chest physiotherapy (RCP) for 10 min (n=25). Measurements and results: Extravascular lung water (EVLW), pulmonary blood volume index (PBVI) and cardiac index (CI) were obtained during mechanical ventilation (T1), T-piece breathing (T2), interventions (T3), spontaneous breathing 60 min (T4) and 90 min (T5) after extubation of the trachea using a combined dye-thermal dilution method. Changing from mechanical ventilation to T-piece breathing did not show any significant differences in EVLW between the three groups, but a significant increase in PBVI from 155±5 ml/m2 to 170±4 ml/m2 could be observed in all groups (p〈0.05). After extubation of the trachea and treatment with BiPAP, PBVI decreased significantly to 134±6 ml/m2 (p〈0.05). After treatment with CPAP or BiPAP, EVLW did not change significantly in these groups (5.5±0.3 ml/kg vs 5.0±0.4 ml/kg and 5.1±0.4 ml/kg vs 5.7±0.4 ml/kg). In the RCP-treated group, however, EVLW increased significantly from 5.8±0.3 ml/kg to 7.1±0.4 ml/kg (p〈0.05). Sixty and 90 min after extubation, EVLW stayed at a significantly higher level in the RCP-treated group (7.5±0.5 ml/kg and 7.4±0.5 ml/kg) than in the CPAP-(5.6±0.3 ml/kg and 5.9±0.4 ml/kg) or BiPAP-treated groups (5.2±0.4 ml/kg and 5.2±0.4 ml/kg). No significant differences in CI could be observed within the three groups during the time period from mechanical ventilation to 90 min after extubation of the trachea. Conclusions: Mask CPAP and nasal BiPAP after extubation of the trachea prevent the increase in extravascular lung water during x weaning from mechanical ventilation. This effect is seen for at least 1 h after the discontinuation of CPAP or BiPAP treatment.Further studies have to evaluate the clinical relevance of this phenomenon.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...