Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1434-4475
    Keywords: cis- andtrans-Dichlorobis(cycloalkylamine)platinum(II) complexes ; Antitumor activity ; MDA-MB-231 Breast cancer cell line
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Die Synthese von Dichlorobis(cycloalkylamin)platin(II)-Komplexen mitcis- undtrans-ständigen Cycloalkylaminliganden [cis-PtCl2(C3H5NH2)2 biscis-PtCl2(C8H15NH2)2 (3–8) sowietrans-PtCl2(C7H13NH2)2 (9) undtrans-PtCl2(C8H15NH2)2 (10)] wird beschrieben. Eine Unterscheidung zwischencis- undtrans-Isomeren konnte mit Hilfe der1H-NMR-Spektroskopie getroffen werden. Die tumorwachstumshemmende Wirkung wurde im Langzeitversuch an der menschlichen MDA-MB-231 Brustkrebszellinie bestimmt. Die Komplexe mit kleinen Cycloalkylaminliganden (3–6) waren weniger, diejenigen mit großen Cycloalkylaminliganden vergleichbar (7) oder besser (8) wirksam als Cisplatin. Überraschenderweise waren diecis/trans Isomeren7/9 und8/10 gleich aktiv. Sämtliche Cycloalkylaminliganden waren unwirksam. IR-spektroskopische Untersuchungen zeigen, daß die Größe des Cycloalkylaminliganden zu keiner signifikanten Veränderung der Pt-Cl Bindungsstärke führt. Es wird angenommen, daß die deutlich stärkere Antitumoraktivität der höheren Homologen7–10 nicht auf eine schnellere Reaktion mit Bionucleophilen wie der DNA zurückzuführen ist. Eine mögliche Erklärung der hohen Aktivität von7–10 liegt in der starken Lipophilie der Komplexe. Diese Annahme wird durch Cytotoxizitätstests an stationären Kulturen gestützt.
    Notes: Summary The syntheses of dichlorobis(cycloalkylamine)platinum(II) complexes withcis andtrans cycloalkylamine ligands [cis-PtCl2(C3H5NH2)2 tocis-PtCl2(C8H15NH2)2 (3–8) andtrans-PtCl2(C7H13NH2)2 (9) andtrans-PtCl2(C8H15NH2)2 (10)] are described. The distinction betweencis andtrans isomers was achieved by1H-NMR spectroscopy. The antitumor activity was determined on the cell proliferation of the human MDA-MB-231 breast cancer cell line during long-term drug exposure. The complexes with small cycloalkylamine ligands (3–6) were inferior, those with large cycloalkylamine ligands were comparable (7) or superior (8) to cisplatin. Surprisingly, thecis/trans isomers7/9 and8/10 were equally active. All cycloalkylamine ligands were inactive. IR-spectroscopic studies showed that the size of the cycloalkylamine ring does not lead to significant differences in the Pt-Cl binding strength. Therefore it is assumed that the markedly stronger antitumor activity of the higher homologues,7–10, is not the result of a faster reaction with bionucleophils such as DNA. A possible explanation of the high activity of7–10 is the strong lipophilicity of the complexes. This assumption was confirmed by toxicity tests against confluent cultures.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1238
    Keywords: Weaning CPAP ; BiPAP ; Extravascular lung water ; Cardiac surgery
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Objective To evaluate the effects of continuous positive airway pressure (CPAP) and bilevel positive airway pressure (BiPAP) on extravascular lung water during weaning from mechanical ventilation in patients following coronary artery bypass grafting. Design Prospective, randomized clinical study. Setting Intensive care unit at a university hospital. Patients Seventy-five patients following coronary artery bypass grafting. Interventions After extubation of the trachea, patients were treated for 30 min with CPAP via face mask (n=25), with nasal BiPAP (n=25), or with oxygen administration via nasal cannula combined with routine chest physiotherapy (RCP) for 10 min (n=25). Measurements and results Extravascular lung water (EVLW), pulmonary blood volume index (PBVI) and cardiac index (CI) were obtained during mechanical ventilation (T1), T-piece breathing (T2), interventions (T3), spontaneous breathing 60 min (T4) and 90 min (T5) after extubation of the trachea using a combined dye-thermal dilution method. Changing from mechanical ventilation to T-piece breathing did not show any significant differences in EVLW between the three groups, but a significant increase in PBVI from 155±5 ml/m2 to 170±4 ml/m2 could be observed in all groups (p〈0.05). After extubation of the trachea and treatment with BiPAP, PBVI decreased significantly to 134±6 ml/m2 (p〈0.05). After treatment with CPAP or BiPAP, EVLW did not change significantly in these groups (5.5±0.3 ml/kg vs 5.0±0.4 ml/kg and 5.1±0.4 ml/kg vs 5.7±0.4 ml/kg). In the RCP-treated group, however, EVLW increased significantly from 5.8±0.3 ml/kg to 7.1±0.4 ml/kg (p〈0.05). Sixty and 90 min after extubation, EVLW stayed at a significantly higher level in the RCP-treated group (7.5±0.5 ml/kg and 7.4±0.5 ml/kg) than in the CPAP-(5.6±0.3 ml/kg and 5.9±0.4 ml/kg). No significant differences in CI could be observed within the three groups during the time period from mechanical ventilation to 90 min after extubation of the trachea. Conclusions Mask CPAP and nasal BiPAP after extubation of the trachea prevent the increase in extravascular lung water during weaning from mechanical ventilation. This effect is seen for at least 1 h after the discontinuation of CPAP or BiPAP treatment. Fuether studies have to evaluate the clinical relavance of this phenomenon.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-1238
    Keywords: Key words Weaning ; CPAP ; BiPAP ; Extravascular lung water ; Cardiac surgery
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Objective: To evaluate the effects of continuous positive airway pressure (CPAP) and bi-level positive airway pressure (BiPAP) on extravascular lung water during weaning from mechanical ventilation in patients following coronary artery bypass grafting. Design; Prospective, randomized clinical study. Setting; Intensive care unit at a university hospital. Patients; Seventy-five patients following coronary artery bypass grafting. Interventions; After extubation of the trachea, patients were treated for 30 min with CPAP via face mask (n=25), with nasal BiPAP (n=25), or with oxygen administration via nasal cannula combined with routine chest physiotherapy (RCP) for 10 min (n=25). Measurements and results: Extravascular lung water (EVLW), pulmonary blood volume index (PBVI) and cardiac index (CI) were obtained during mechanical ventilation (T1), T-piece breathing (T2), interventions (T3), spontaneous breathing 60 min (T4) and 90 min (T5) after extubation of the trachea using a combined dye-thermal dilution method. Changing from mechanical ventilation to T-piece breathing did not show any significant differences in EVLW between the three groups, but a significant increase in PBVI from 155±5 ml/m2 to 170±4 ml/m2 could be observed in all groups (p〈0.05). After extubation of the trachea and treatment with BiPAP, PBVI decreased significantly to 134±6 ml/m2 (p〈0.05). After treatment with CPAP or BiPAP, EVLW did not change significantly in these groups (5.5±0.3 ml/kg vs 5.0±0.4 ml/kg and 5.1±0.4 ml/kg vs 5.7±0.4 ml/kg). In the RCP-treated group, however, EVLW increased significantly from 5.8±0.3 ml/kg to 7.1±0.4 ml/kg (p〈0.05). Sixty and 90 min after extubation, EVLW stayed at a significantly higher level in the RCP-treated group (7.5±0.5 ml/kg and 7.4±0.5 ml/kg) than in the CPAP-(5.6±0.3 ml/kg and 5.9±0.4 ml/kg) or BiPAP-treated groups (5.2±0.4 ml/kg and 5.2±0.4 ml/kg). No significant differences in CI could be observed within the three groups during the time period from mechanical ventilation to 90 min after extubation of the trachea. Conclusions: Mask CPAP and nasal BiPAP after extubation of the trachea prevent the increase in extravascular lung water during x weaning from mechanical ventilation. This effect is seen for at least 1 h after the discontinuation of CPAP or BiPAP treatment.Further studies have to evaluate the clinical relevance of this phenomenon.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...