Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Pflügers Archiv 336 (1972), S. 217-224 
    ISSN: 1432-2013
    Keywords: H2 Clearance ; Carotid Body ; Blood Flow ; Chemoreceptor Function
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary A technique is described which enables the determination of local blood flow in different points of the carotid body. The blood flow measured in the middle zone of the catorid body at mean blood pressure of 120 to 130 mm Hg was about 2000 ml/100 gxmin and corresponded to the total flow values known thus far. It was found that the flow/g weight decreases from the arterial inflow towards the periphery. Under our experimental conditions no signs of autoregulation could be detected. Under special experimental conditions differnnt flow distributions were observed in the carotid body.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Cell & tissue research 142 (1973), S. 515-524 
    ISSN: 1432-0878
    Keywords: Arteriovenous anastomoses ; Carotid body ; Cat ; Corrosion casting technique ; Scanning electron microscopy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Description / Table of Contents: Zusammenfassung In den arteriennahen, peripheren Bereichen des Glomus caroticum der Katze wurden arteriovenöse Verbindungen nachgewiesen, die ihrem Charakter nach unterschiedlich sind. Es ist allerdings noch nicht zu entscheiden, ob derartige Anastomosen regelmäßig vorkommen und wie sie funktionieren. Die beschriebenen Gefäßverbindungen konnten lichtmikroskopisch anhand von histologischen Serienschnitten und mit Hilfe einer weiterentwickelten Korrosionstechnik im Rasterelektronenmikroskop dargestellt werden.
    Notes: Summary In artery surrounding areas in the periphery of the carotid body of the cat we found arteriovenous anastomoses differing in respect to their character. So far, it is not yet to decide the frequency of their occurrence and their functional significance. The anastomoses were demonstrated by light microscopy of serial sections and by scanning electron microscopy with a more developed corrosion casting technique.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...