Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 13 (1973), S. 53-62 
    ISSN: 1432-0827
    Keywords: Bioelectric potentials ; Bone ; Negativity ; Cells ; viability
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Description / Table of Contents: Résumé Des potentiels électriques sont enregistrés au niveau du tibia, au repos, d'un lapin anesthésié, et cela à l'aide d'électrodes d'argent/chlorure d'argent, reliées à des ponts salins et un voltmètre à haute impédance. Les potentiels enregistrés à partir des surfaces antérieures, médianes et latérales du tibia indiquent que le voltage de surface est constant autour de l'axe transversale de l'os, mais varie en rapport avec l'axe longitudinal. Les voltages sont indépendants des limites osseuses et points d'attaches musculaires. Ces potentiels bioélectriques varient peu après résection du nerf sciatique ou ligature de l'artère fémorale. Les potentiels décroissent nettement trente minutes après administration intra-artérielle de dinitrophénol ou iodoacétamide. Les potentiels chutent nettement dans un segment localisé du tibia, endommagé par application d'ultra-sons. La mort de l'animal provoque une chute lente de potentiel en rapport avec la perte graduelle de viabilité des cellules osseuses. Il semble que les potentiels de repos, observés à la surface de l'os non stressé, ne sont pas directement liés à la circulation sanguine ou la transmission neurale. Ces potentiels semblent plutôt liés à l'existence d'une population cellulaire osseuse active et chaque potentiel mesuré constitue la somme des forces électromotrices de toutes les cellules d'une région localisée.
    Abstract: Zusammenfassung Am anaesthesierten Kaninchen wurden die Biopotentiale der unbelasteten Tibia gemessen. Dazu wurden Silber/Silberchlorid-Elektroden benützt, welche über Salzbrücken an ein Voltmeter mit hohem Eingangswiderstand angeschlossen waren. Die an der vorderen, seitlichen und hinteren Tibia-Oberfläche gemessenen Potentiale zeigten, daß die Oberflächenspannung an der Querachse eines Knochens konstant ist, jedoch in bezug zur Längsachse variiert. Die Spannungen waren nicht beeinflußt durch knochentopographische und Muskelansatz-Punkte. Nach Sciaticus-Durchtrennung oder Ligatur der Arterie femoralis änderten sich die bioelektrischen Potentiale nur wenig. Ein eindrücklicher Abfall der Potentiale wurde jedoch 30 min nach intraarterieller Verabreichung von Dinitrophenol oder Jodacetamied beobachtet. Ebenso stark fielen die Potentiale in einem umgrenzten Tibia-Segment ab, das durch Ultraschallbehandlung lädiert worden war. Beim Tod der Tiere wurde ein langsamer Abfall der Potentiale, entsprechend dem allmählichen Verlust an lebenden Knochenzellen, beobachtet. Auf Grund der mit dieser Studie gewonnenen Resultate kann vermutet werden, daß die im Gleichgewicht bleibenden Potentiale der unbelasteten Knochenoberfläche nicht direkt von der Durchblutung oder der nervösen Reizleitung abhängig sind. Es scheint eher, daß dafür eine intakte Knochenzell-Population vorliegen muß, wobei jedes aufgezeichnete Potential eine Summierung der elektromotorischen Kräfte aller Zellen einer bestimmten Region darstellt.
    Notes: Abstract Bioelectric potentials were recorded from the unstressed tibia in the anesthetized rabbit by means of silver/silver chloride electrodes connected to saline bridges and a high impedence voltmeter. Potentials recorded from the anterior, medial, and lateral surfaces of the tibia indicated that the surface voltage was constant around the transverse axis of a bone but varied in relation to its long axis. Voltages were independent of bony landmarks and points of muscle attachment. The bioelectric potentials changed little after sciatic nerve denervation or ligation of the femoral artery. The potentials decreased dramatically thirty minutes following the intra-arterial administration of dinitrophenol or iodoacetamide. Also, the potentials fell sharply in a localized segment of tibia injured through the application of ultrasound energy. Animal death brought about a slow decay of potential commensurate with the gradual loss of bone cell viability. The experimental evidence from this study suggests that the steady state potentials observed from the surface of unstressed bone are not directly dependent on blood flow or nerve transmission. Rather, such potentials are dependent on a functioning bone cell population, and each recorded potential represents a summation of the electromotive forces from all cells in a localized area.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Hoboken, NJ [u.a.] : Wiley-Blackwell
    Journal of Orthopaedic Research 3 (1985), S. 125-136 
    ISSN: 0736-0266
    Keywords: Electrical stimulation ; Osteogenesis ; Platinum ; Stainless steel ; Electrode materials ; Microtrauma ; Life and Medical Sciences
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: Studies of electrical stimulation of osteogenesis with stainless steel electrodes have previously established a dose-response relationship between current and bone growth. Examination of the effect of different geometric current densities resulted in the conclusion that very little electrode surface area was involved in stimulation and led to the design of a multiport “distributive” cathode. A series of experiments were performed to extend these results to wire and multiport platinum electrodes. As before, a current-bone growth dose-response relationship was found. Peak bone growth was greater than for stainless steel. However, peak bone growth occurred at 2.0 μA (versus 20 μA for stainless steel). Correlation studies suggest that small changes in cathodic potential affect bone growth more than similar size changes in current. Finally, the generally benign local host response to platinum suggests that platinum may be a suitable materials for chronic indwelling anodes for stimulation of osteogenesis.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...