Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 47 (1998), S. 313-345 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Sample pretreatment ; Coupling on-line to capillary GC ; Robotization
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Sample pretreatment is often the bottleneck of a tracelevel analytical procedure. In order to increase performance, increasing attention is therefore being devoted to combining sample pretreatment on-line with the separation technique that has to be used. In the present review, a variety of procedures in use today for sample treatment coupled on-line to capillary gas chromatography (GC) is briefly discussed. Special attention is devoted to coupled-column techniques such as SPE-GC and LC-GC (SPE, solid-phase extraction; LC, column liquid chromatography) which are topics of much current interest, also because of their frequent use in so-called hyphenated systems.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Column liquid chromatography ; Solid-phase microextraction ; Local anaesthetic lidocaine ; Optimisation of extraction
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Solid-phase microextraction (SPME) has been combined with gas chromatography (GC) and liquid chromatography (LC) for the determination of lidocaine in human urine. A polydimethylsiloxane (PDMS) coated fibre was directly immersed into buffered urine. Extraction conditions such as time, pH, ionic strength, temperature, and agitation were optimised. The extracted lidocaine was thermally desorbed in a split/splitless injector for analysis with a GC-FID system or desorbed with liquid in a specially designed SPME-LC interface for analysis with an LC-UV system. After optimisation the method developed was evaluated and validated. Extraction yields of 22% were obtained in about 45 min. The reproducibility of the method is 〈5% (relative standard deviation). For five-times diluted urine, linear ranges were found from 5–1000 and 25–1000 ng·mL−1 for SPME-GC and SPME-LC, with detection limits of 5 ng·mL−1 for SPME-GC and 25 ng·mL−1 for SPME-LC. SPME can be used as a simple sample pretreatment method for the determination of lidocaine in urine by GC and LC.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1612-1112
    Keywords: Chemical excitation source ; Chemiluminescence detector ; Chemical band narrowing ; Dansyl derivative ; Serum
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A peroxyoxalate chemiluminescence detection system for liquid chromatography is described. The excitation of fluorophores is generated by the reaction of bis-(2,4,6-trichlorophenyl)oxalate or bis(2,4-dinitrophenyl)oxalate and hydrogen peroxide, which are added to the column effluent. The influence of the solvents and the concentrations of the reagents have been investigated. The influence of the flow cell volume on sensitivity and on band broadening have also been studied and a “chemical band narrowing effect” has been observed. Different types of apparatus have been compared for detection of the emitted light. The system has been used for the detection of the dansyl derivative of a drug with a secondary amine functional group in serum samples. The detection limits are in the 1–10pg range.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Column liquid chromatography ; On-line coupling ; Ion-exchange membrane ; Ion-pair reagent
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary In order to enable the coupling of reversed-phase liquid chromatography (RPLC) with capillary gas chromatography (GC), the performance of an anion-exchange micromembrane device has been studied to remove the ion-pair reagent methanesulphonic acid from an acetonitrile/water LC eluent. The regenerant in the membrane was tetrabutylammonium hydroxide dissolved in acetonitrile/water, which effects an anion-exchange of methanesulphonate ions for regenerant hydroxide ions. The efficiency of the exchange process was found to be 99.9%. This enabled the direct introduction of the LC eluent, free of ions and with the proper acetonitrile/water ratio, into the GC. The applicability of the on-line LC-micromembrane-GC system has been illustrated for the potential drug eltoprazine, which is quantitatively recovered with a coefficient of variation for standard solutions of 3% at the 150 μg/ml analyte level.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...