Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Neuroradiology 33 (1991), S. 362-363 
    ISSN: 1432-1920
    Keywords: Human immunodeficiency virus (HIV) ; Encephalitis ; Magnetic resonance imaging ; AIDS
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary We report two patients with HIV infection whose MR imaging showed abnormal high signal intensity confined to both putamina on T2-weighted spin echo (SE) images. We assume that they may represent the early manifestations of HIV encephalitis.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Neuroradiology 33 (1991), S. 520-523 
    ISSN: 1432-1920
    Keywords: Magnetic resonance imaging ; Encephalitis ; Limbic system
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary In two patients with limbic encephalitis serial magnetic resonance (MR) imaging showed evolution of abnormal high-signal intensity in both hippocampal formations on T2-weighted images.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-1920
    Keywords: Key words Orbit ; Silicone ; MRI ; Chemical shift
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We imaged two patients who had silicone oil injected into their vitreous cavities. The images demonstrated an increased chemical shift artifact. We developed and tested an in vitro silicone oil model in an attempt to explain this. To our knowledge, this artifact has not been previously described. We constructed a phantom using medication cups containing water, lard and two types of silicone. Background control baths of water and lard were used to simulate different local environments. The phantoms were imaged with T1- and T2-weighted and T1-weighted fat suppression sequences. The artifacts were due to the pronounced chemical shift of silicone in relation to intraconal fat. Our model accurately reproduced our clinical images. Spectral analysis of the silicone model revealed different resonating frequencies for fat/silicone, thereby explaining the pronounced chemical shift artifact.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1432-1920
    Keywords: Orbit ; Silicone ; MRI ; Chemical shift
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We imaged two patients who had silicone oil injected into their vitreous cavities. The images demonstrated an increased chemical shift artifact. We developed and tested an in vitro silicone oil model in an attempt to explain this. To our knowledge, this artifact has not been previously described. We constructed a phantom using medication cups containing water, lard and two types of silicone. Background control baths of water and lard were used to simulate different local environments. The phantoms were imaged with T1- and T2-weighted and T1-weighted fat suppression sequences. The artifacts were due to the pronounced chemical shift of silicone in relation to intraconal fat. Our model accurately reproduced our clinical images. Spectral analysis of the silicone model revealed different resonating frequencies for fat/silicone, thereby explaining the pronouced chemical shift artifact.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...